Custom Anterior Surfacing of Scleral Lens for Vision Quality Improvement in Patients With Keratoconus
NCT ID: NCT03647046
Last Updated: 2020-03-31
Study Results
Outcome measurements, participant flow, baseline characteristics, and adverse events have been published for this study.
View full resultsBasic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
NA
12 participants
INTERVENTIONAL
2018-10-08
2020-01-20
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Effect of Lens Presentation on the Clinical Oculomotor Assessment at Near
NCT02679313
The Berkeley Orthokeratology Study
NCT00000123
Comparison of Standard vs. Accelerated Corneal Crosslinking
NCT03922542
CHOICE OF SUBJECTIVE OCULAR REFRACTION TECHNIQUE AND CORNEAL TOPOGRAPHY OF KERATOCONUS
NCT04174209
Controlling Myopia Progression With Soft Contact Lenses (Contact Lens Control)
NCT01829191
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
The study eye will be chosen based on inclusion criteria; if both eyes qualify, the eye with worse best corrected acuity will be chosen. A new lens will be manufactured for the subject after the screening visit and will be given to the subject during the following study visit. This is done to ensure fully neutralized spherical refractive effort and positional stability. If screening evaluation reveals that the current lens does not fully neutralize spherical refractive error or that the current lens is not positionally stable, a baseline lens will be manufactured that corrects this. The subject will be allowed to keep the old lens if he or she so chooses.
At the second visit, the patient's vision and fit will be evaluated with the optimized baseline BSS lens. Visual acuity and device fit will be evaluated and recorded. If the BSS device fit is still not optimized, then a new device will be made , and the second visit evaluation will be rescheduled. Once the baseline lens design is determined to be satisfactory, the patient will have their wavefront aberration measured with a wavefront sensor. Investigators will dilate the pupil pharmacologically with phenylephrine (2.5%) and tropicamide (1%) and take wavefront measurements of the optical aberrations of the subject's eye wearing the baseline lens using a portable, non-invasive wavefront analyzer designed to measure highly aberrated eyes (Ovitz, P10/EyeProfiler). The investigators will then design and manufacture a study lens that is identical in design to the baseline BostonSight BSS lens except for a custom front surface designed to neutralize the optical aberrations measured with the wavefront analyzer. This HOA-optimized lens will be created prior to the third visit.
At the third visit the patient's vision and fit will be evaluated with the new HOA-optimized lens. A designated study team member will measure visual acuity and over-refraction of the patient. If an adjustment is needed for the lens, then a new device will be made, and the third visit evaluation will be rescheduled.
Once well-fitting baseline and HOA-optimized test lenses are established, both lenses will be remade and presented to the evaluator designated study team member in charge of evaluation and subject together in a masked fashion. During a fourth visit, the patient's vision will be extensively evaluated using standard non-invasive optometric measurements with each of the two lenses. First the patient will undergo a basic evaluation with each lens to ensure that the fit is correct. The patient will then undergo basic visual acuity; high and low contrast visual acuity, contrast sensitivity, and subjective vision scoring with each lens. The subject's wavefront aberration will also be measured again with each lens.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NA
SINGLE_GROUP
BASIC_SCIENCE
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Customized Scleral Lens
A customized scleral lens will be compared with a non-customized scleral lens in subjects with Keratoconus through vision tests.
Customized Scleral Lens
A wavefront customized scleral lens will be made for each subject and tested against a non-customized lens.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Customized Scleral Lens
A wavefront customized scleral lens will be made for each subject and tested against a non-customized lens.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Exclusion Criteria
* Has best corrected visual acuity outside 20/400;
* Pregnant or nursing at the time of enrollment in the study;
18 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Ovitz Corporation
INDUSTRY
Boston Sight
OTHER
University of Rochester
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Tara Vaz
Assistant Professor
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Flaum Eye Institute, University of Rochester Medical Center
Rochester, New York, United States
Countries
Review the countries where the study has at least one active or historical site.
Provided Documents
Download supplemental materials such as informed consent forms, study protocols, or participant manuals.
Document Type: Study Protocol and Statistical Analysis Plan
Document Type: Informed Consent Form
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
72749
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.