Workflow Validation of an In-Home Feedback Controlled Mandibular Positioner
NCT ID: NCT03616327
Last Updated: 2019-08-21
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
NA
10 participants
INTERVENTIONAL
2017-11-01
2019-08-19
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Workflow Validation of an In-home Auto-titrating Mandibular Positioner
NCT02933112
Feasibility and Predictive Accuracy of an In-Home Computer Controlled Mandibular Positioner in Identifying Favorable Candidates for Oral Appliance Therapy
NCT03011762
A Study for Obstructive Sleep Apnea Using a New At-Home Sleep Test
NCT03049982
Acceptance of Mandibular Advancement Devices
NCT06970171
Validation of a Simplified MATRx Plus
NCT03812692
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Oral appliance treatment does not treat sleep apnea effectively in all patients. In order to identify those patients for whom oral appliance therapy will work, Zephyr Sleep Technologies has invented a remotely controlled device that tests various positions of the lower jaw. This commercially available device, known as MATRx, is an FDA-cleared motorized dental positioner that can be used in an overnight sleep study performed in the hospital or clinic. Temporary dental-impression trays cover the upper and lower teeth. These are attached to a small motor that slowly and gently pulls the lower jaw forward under the control of a technician who determines when the best position is reached. Knowing the best position, and the likelihood of future success, allows the dentist to build an oral appliance with confidence.
In order to eliminate the need for an overnight in-hospital sleep study, Zephyr Sleep Technologies has invented a new investigational device that allows clinicians to decide whether or not an individual is likely to benefit from oral appliance therapy, from the comfort of the individual's own home. An investigational device is one that is not cleared by the U.S. Food and Drug Administration (FDA). Like the MATRx, the patient sleeps with a motorized positioner that moves the lower jaw. However, the new device (called MATRx plus) is automatically controlled by a computer, rather than a sleep technician, making it a feedback controlled mandibular positioner. Participation in this study will provide important data regarding the use of these device in their intended commercial setting, the dentist's office.
Zephyr has previously carried out three research studies leading to the development of this feedback controlled mandibular positioner. The first study showed that the technician controlled positioner was able to accurately identify patients suitable for oral-appliance therapy, i.e., those with a good likelihood of success with a permanent device.
This study also identified the amount of jaw protrusion (how far forward the lower jaw needs to be pulled) that will provide therapeutic relief of the patients' sleep apnea. This trial resulted in the placement of the device on the market, now sold in the United States as MATRx. The second two trials showed that the feedback controlled software used by the new positioner was very accurate and was able to identify successful candidates in a home setting.
No serious or permanent problems or risks were identified in any of these research studies. Participants reported minor tooth and gum discomfort on the morning following the test and other minor issues including canker sores, excess saliva and being unable to sleep. Since other studies were designed to establish the safety and efficacy of the device, the purpose of the present research study is to collect additional data regarding the workflow of the device as it would occur during commercial use.
The test will occur over a series of nights in the home or during a single night in the sleep laboratory. The test type will be decided by the care providers and this study will only document the rationale and will not influence the choice of test. Participants will be asked to provide feedback as to the preferred test, and will be told if they are candidates for oral appliance therapy based on the output of the test.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NA
SINGLE_GROUP
OTHER
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
MATRx in-lab or MATRx plus test
Participants will undergo the MATRx in-lab or MATRx plus home test to determine adequacy for mandibular repositioning oral appliance therapy. The tests only differ in their setting (i.e., in the sleep lab or at home). All participants will receive the same treatment protocol preceding and following the MATRx/MATRx plus test.
MATRx in-lab, MATRx plus
The MATRx remotely controlled mandibular positioner (RCMP) consists of temporary dental trays connected to an extra-oral linear actuator that protrudes the mandible. MATRx is used during polysomnography, where sleep and cardio-respiratory variables are recorded during sleep. The position of the mandible is controlled remotely by a sleep technologist, who moves the mandible while monitoring cardio-respiratory variables. The test determines if mandibular protrusion eliminates pharyngeal obstruction and the required protrusion. The MATRx plus is used in the home. Like the RCMP, the patient sleeps with the motorized mandibular positioner (MP) in place. However, the MP's position is controlled by a computer, making it a feedback controlled mandibular positioner (FCMP). The FCMP detects apneas and hypopneas in real time. Using this information, the controller decides when to move the mandible and by how much. The test predicts of therapeutic outcome with OA and provides a target protrusion.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
MATRx in-lab, MATRx plus
The MATRx remotely controlled mandibular positioner (RCMP) consists of temporary dental trays connected to an extra-oral linear actuator that protrudes the mandible. MATRx is used during polysomnography, where sleep and cardio-respiratory variables are recorded during sleep. The position of the mandible is controlled remotely by a sleep technologist, who moves the mandible while monitoring cardio-respiratory variables. The test determines if mandibular protrusion eliminates pharyngeal obstruction and the required protrusion. The MATRx plus is used in the home. Like the RCMP, the patient sleeps with the motorized mandibular positioner (MP) in place. However, the MP's position is controlled by a computer, making it a feedback controlled mandibular positioner (FCMP). The FCMP detects apneas and hypopneas in real time. Using this information, the controller decides when to move the mandible and by how much. The test predicts of therapeutic outcome with OA and provides a target protrusion.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Participant has been deemed suitable for oral appliance therapy
* Adequate mandibular range of motion
* Adequate dentition
* Ability to understand and provide informed consent
* Ability and willingness to meet the required schedule
Exclusion Criteria
* Full dentures
18 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Zephyr Sleep Technologies
INDUSTRY
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Kent Moore, DDS, MD
Role: PRINCIPAL_INVESTIGATOR
Charlotte Oral Surgery
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Charlotte Oral Surgery
Charlotte, North Carolina, United States
Countries
Review the countries where the study has at least one active or historical site.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
ZCP201705
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.