Workflow Validation of an In-Home Feedback Controlled Mandibular Positioner

NCT ID: NCT03616327

Last Updated: 2019-08-21

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Clinical Phase

NA

Total Enrollment

10 participants

Study Classification

INTERVENTIONAL

Study Start Date

2017-11-01

Study Completion Date

2019-08-19

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

The purpose of the study is to test the workflow of the MATRx and MATRx plus feedback controlled mandibular positioner in its intended setting and considerations related to decision making by the care provider. The workflow includes the participant's recruitment into the study, the screening process, visits at the dentist, home sleep tests, and the decision made regarding oral appliance therapy based on the results of the sleep tests.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Sleep apnea (OSA) is a condition in which the air passage in the throat closes or partly closes during sleep and repeatedly interrupts breathing. The standard treatment of sleep apnea is continuous positive airway pressure (CPAP) applied to the nose, but it is not suitable for all patients. Another treatment is to use an oral appliance in the mouth during sleep. The appliance covers the upper and lower teeth and acts to pull the lower jaw forward, opening the throat passage and allowing normal breathing.

Oral appliance treatment does not treat sleep apnea effectively in all patients. In order to identify those patients for whom oral appliance therapy will work, Zephyr Sleep Technologies has invented a remotely controlled device that tests various positions of the lower jaw. This commercially available device, known as MATRx, is an FDA-cleared motorized dental positioner that can be used in an overnight sleep study performed in the hospital or clinic. Temporary dental-impression trays cover the upper and lower teeth. These are attached to a small motor that slowly and gently pulls the lower jaw forward under the control of a technician who determines when the best position is reached. Knowing the best position, and the likelihood of future success, allows the dentist to build an oral appliance with confidence.

In order to eliminate the need for an overnight in-hospital sleep study, Zephyr Sleep Technologies has invented a new investigational device that allows clinicians to decide whether or not an individual is likely to benefit from oral appliance therapy, from the comfort of the individual's own home. An investigational device is one that is not cleared by the U.S. Food and Drug Administration (FDA). Like the MATRx, the patient sleeps with a motorized positioner that moves the lower jaw. However, the new device (called MATRx plus) is automatically controlled by a computer, rather than a sleep technician, making it a feedback controlled mandibular positioner. Participation in this study will provide important data regarding the use of these device in their intended commercial setting, the dentist's office.

Zephyr has previously carried out three research studies leading to the development of this feedback controlled mandibular positioner. The first study showed that the technician controlled positioner was able to accurately identify patients suitable for oral-appliance therapy, i.e., those with a good likelihood of success with a permanent device.

This study also identified the amount of jaw protrusion (how far forward the lower jaw needs to be pulled) that will provide therapeutic relief of the patients' sleep apnea. This trial resulted in the placement of the device on the market, now sold in the United States as MATRx. The second two trials showed that the feedback controlled software used by the new positioner was very accurate and was able to identify successful candidates in a home setting.

No serious or permanent problems or risks were identified in any of these research studies. Participants reported minor tooth and gum discomfort on the morning following the test and other minor issues including canker sores, excess saliva and being unable to sleep. Since other studies were designed to establish the safety and efficacy of the device, the purpose of the present research study is to collect additional data regarding the workflow of the device as it would occur during commercial use.

The test will occur over a series of nights in the home or during a single night in the sleep laboratory. The test type will be decided by the care providers and this study will only document the rationale and will not influence the choice of test. Participants will be asked to provide feedback as to the preferred test, and will be told if they are candidates for oral appliance therapy based on the output of the test.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Obstructive Sleep Apnea

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

NA

Intervention Model

SINGLE_GROUP

Primary Study Purpose

OTHER

Blinding Strategy

NONE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

MATRx in-lab or MATRx plus test

Participants will undergo the MATRx in-lab or MATRx plus home test to determine adequacy for mandibular repositioning oral appliance therapy. The tests only differ in their setting (i.e., in the sleep lab or at home). All participants will receive the same treatment protocol preceding and following the MATRx/MATRx plus test.

Group Type OTHER

MATRx in-lab, MATRx plus

Intervention Type DEVICE

The MATRx remotely controlled mandibular positioner (RCMP) consists of temporary dental trays connected to an extra-oral linear actuator that protrudes the mandible. MATRx is used during polysomnography, where sleep and cardio-respiratory variables are recorded during sleep. The position of the mandible is controlled remotely by a sleep technologist, who moves the mandible while monitoring cardio-respiratory variables. The test determines if mandibular protrusion eliminates pharyngeal obstruction and the required protrusion. The MATRx plus is used in the home. Like the RCMP, the patient sleeps with the motorized mandibular positioner (MP) in place. However, the MP's position is controlled by a computer, making it a feedback controlled mandibular positioner (FCMP). The FCMP detects apneas and hypopneas in real time. Using this information, the controller decides when to move the mandible and by how much. The test predicts of therapeutic outcome with OA and provides a target protrusion.

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

MATRx in-lab, MATRx plus

The MATRx remotely controlled mandibular positioner (RCMP) consists of temporary dental trays connected to an extra-oral linear actuator that protrudes the mandible. MATRx is used during polysomnography, where sleep and cardio-respiratory variables are recorded during sleep. The position of the mandible is controlled remotely by a sleep technologist, who moves the mandible while monitoring cardio-respiratory variables. The test determines if mandibular protrusion eliminates pharyngeal obstruction and the required protrusion. The MATRx plus is used in the home. Like the RCMP, the patient sleeps with the motorized mandibular positioner (MP) in place. However, the MP's position is controlled by a computer, making it a feedback controlled mandibular positioner (FCMP). The FCMP detects apneas and hypopneas in real time. Using this information, the controller decides when to move the mandible and by how much. The test predicts of therapeutic outcome with OA and provides a target protrusion.

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Minimum 18 years of age
* Participant has been deemed suitable for oral appliance therapy
* Adequate mandibular range of motion
* Adequate dentition
* Ability to understand and provide informed consent
* Ability and willingness to meet the required schedule

Exclusion Criteria

* Loose teeth or advanced periodontal disease
* Full dentures
Minimum Eligible Age

18 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Zephyr Sleep Technologies

INDUSTRY

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Responsibility Role SPONSOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Kent Moore, DDS, MD

Role: PRINCIPAL_INVESTIGATOR

Charlotte Oral Surgery

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Charlotte Oral Surgery

Charlotte, North Carolina, United States

Site Status

Countries

Review the countries where the study has at least one active or historical site.

United States

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

ZCP201705

Identifier Type: -

Identifier Source: org_study_id