Pilot Clinical Study on a Low-power Electromagnetic Wave Breast Imaging Device for Cancer Screening Purposes.

NCT ID: NCT03475992

Last Updated: 2021-06-07

Study Results

Results available

Outcome measurements, participant flow, baseline characteristics, and adverse events have been published for this study.

View full results

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Clinical Phase

NA

Total Enrollment

25 participants

Study Classification

INTERVENTIONAL

Study Start Date

2018-10-10

Study Completion Date

2020-05-07

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

The trialed investigational medical imaging device is a low-power microwave breast imaging system for cancer screening purposes. It is an active device which uses non-ionizing radiation.

Microwave imaging is an emerging imaging modality for the early detection of the breast cancer. The physical basis of microwave imaging is the dielectric contrast between healthy and cancerous breast tissues at microwave frequencies. Microwave imaging can potentially be used for monitoring neoadjuvant chemotherapy treatment, breast health monitoring, and for routine screening and diagnosis of the breast cancer at the early-stage. The non-invasive and the non-ionizing characteristics of microwaves should allow for frequent scans of the breast using microwave imaging, unlike X-ray mammography. In addition to safety, microwave imaging does not require uncomfortable breast compression and it is potentially a lower-cost modality.

This is a first-in-human clinical test of the investigational device, which has been so far tested only with experimental phantoms modelling the human female breast.

The clinical data that will be collected in the context of this study is intended to provide early safety information for the investigational medical imaging device. In addition, this exploratory data will guide the refinement of the device hardware and the imaging algorithm design, before decision to proceed (or not) with further clinical tests.

Furthermore, this study will be used to guide sample size calculation for a subsequent study designed to evaluate efficacy should that appear warranted once this study is completed.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

This is a single-site early-phase pilot clinical study, taking place at Galway University Hospital/HRB Clinical Research Facility, Galway.

Patients will have a conventional history and breast examinations (Mammogram and / or Ultrasound and Clinical assessment) performed by the physician, as per normal practice in the Symptomatic Breast Unit of University Hospital Galway.

If patients are interested in the study, provide written informed consent and are deemed eligible, they will attend the Clinical Research Facility Galway for a Microwave Breast Imaging (MBI) scan. The data from the scan will be collected and stored securely. Patients will be followed up 7-21 days after the microwave breast investigation or before surgery, whichever comes first. Patients will be assessed for their experience of the microwave breast investigation, and for any adverse events.

The investigational medical imaging device consists of two subsystems, both performing a non-invasive examination:

* the Microwave Breast Imaging subsystem (MBI subsystem);
* the Optical Breast Contour Detection subsystem (OBCD subsystem);

The MBI subsystem is an active device which uses non-ionizing radiation. It illuminates the breast with low-power electromagnetic waves in the microwave frequency spectrum, which penetrate the breast under examination. The subsystem collects the scattered electromagnetic waves and recovers useful information on the breast tissue consistency, given the dielectric contrast of these tissues.

Multi-static radar detection technology is employed in the MBI subsystem for breast image formation.The well-established Microwave Vision Group (MVG) technology for fast antenna measurement, using multiple sensors in a vertical arch configuration, has been transposed to a horizontal arch of sensors. In addition, vertical translation of the horizontal arch has been enabled, such that 3D multi-static short-range radar imaging is possible.

The sensors are in contact with a cylindrical container filled with a liquid; the so-called coupling liquid has been designed to have electromagnetic (EM) properties appropriately selected such that the EM wave penetration in the breast is maximized.

During the MBI scan, the patient is lying in a face down position on a special bed, integrated with the MBI subsystem. The breast under examination is immersed in the coupling liquid, through a dedicated circular opening of the bed. The breast is then scanned. This vertical scan takes approximately 10-15 minutes to complete, depending on the size of each breast.

In order to compute the required volume of coupling liquid, such that the container of the MBI subsystem is optimally filled after immersion of the breast, a simple process for optical assessment of the total volume of the breast takes place just before starting the MBI scan.

The Optical Breast Contour Detection (OBCD) subsystem serves to provide the total volume of the breast, and also its external contour, as a priori information to the MBI subsystem. The OBCD subsystem consists of a 3D optical camera placed below the examination table, at a distance of several tens of centimetres below the breast. An azimuthal scan of the 3D camera permits to reconstruct the external surface of the breast.

In order for the breast contour to be a useful a priori information for the MBI subsystem, it is important that the patient is lying in the same face down position during both the MBI and OBCD scans. Thus, an identical examination table, as the one integrated with the MBI subsystem, is also integrated with the OBCD subsystem. During the OBCD scan, the patient is lying on the examination table, with her breast under examination inserted in the circular opening of the examination table. For this scan, there is no coupling liquid; the breast is in the air, hanging below the examination table.

Both the breast bearing the palpable lump and the contralateral breast will be scanned. The contralateral breast scan will serve as control in the data analysis.

The MBI scan duration of each breast should not exceed 15 minutes. The recorded data will be checked and in the case of non-optimal positioning of the patient, the scan may be repeated.

It is expected that the duration of the microwave breast investigation (including OBCD scan of both breasts for breast volume assessment, preparation of the MBI subsystem, MBI scan of both breasts, and data verification) should not exceed 1 hour. If the Data Quality Check suggests repetition of the MBI scan, and upon agreement by the patient, the total duration of the microwave breast investigation will be extended.

The written radiology reports from conventional imaging will be acquired and used to evaluate the performance of the MBI subsystem in terms of detecting and estimating the size and consistency of the breast lump.

MBI data analysis will be performed off-line, at MVG premises (France), and is expected to be completed few months after the end-date of data collection. Following the assessment of the MBI results by the medical experts involved in the study, a decision will be made regarding the potential of this emerging imaging modality and the interest in proceeding with clinical studies involving larger sample sizes. Based on these results, MVG will decide and plan actions for refinement of the system, towards an upgraded version to be used for potential future tests with a more significant impact.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Breast Cancer Breast Cyst

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

NON_RANDOMIZED

Intervention Model

PARALLEL

The study is performed on 3 groups of patients:

* Group 1: 15 patients with pre-diagnosed breast cancer (core needle biopsy performed ≥14 days before the microwave breast investigation).
* Group 2: 10 patients with breast cyst. No prior biopsy
* Group 3: 5 patients with pre-diagnosed benign lesion (core needle biopsy performed ≥14 days before the microwave breast investigation).
Primary Study Purpose

DIAGNOSTIC

Blinding Strategy

NONE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Pre-diagnosed breast cancer

Low-power microwave breast imaging system.

Core needle biopsy performed ≥14 days before the microwave breast investigation

Group Type EXPERIMENTAL

Low-power microwave breast imaging system

Intervention Type DEVICE

Investigate the capacity of microwave imaging to detect and characterise diagnosed palpable breast lump

Pre-diagnosed breast cyst

Low-power microwave breast imaging system.

No prior biopsy

Group Type EXPERIMENTAL

Low-power microwave breast imaging system

Intervention Type DEVICE

Investigate the capacity of microwave imaging to detect and characterise diagnosed palpable breast lump

Pre-diagnosed benign lesion

Low-power microwave breast imaging system.

Core needle biopsy performed ≥14 days before the microwave breast investigation

Group Type EXPERIMENTAL

Low-power microwave breast imaging system

Intervention Type DEVICE

Investigate the capacity of microwave imaging to detect and characterise diagnosed palpable breast lump

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Low-power microwave breast imaging system

Investigate the capacity of microwave imaging to detect and characterise diagnosed palpable breast lump

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

1. Subjects must be able and willing to give written informed consent and to comply with the requirements of this study protocol
2. Subject must have attended the Symptomatic Breast Unit with a palpable breast lump
3. Subjects must have had a mammogram in the clinical assessment period (≤ 6 weeks before the microwave breast investigation)
4. Subjects must be able to comfortably lie reasonably still in a prone position for up to 15 minutes
5. Subjects with bra size larger than 32B and cup size larger or equal to B.
6. Subjects whose breast size is adapted to the cylindrical container of the MBI system with sufficient margin to allow the presence of transition liquid around the breast. Final decision to be taken by the physicians based on their judgement.

Exclusion Criteria

1. Subjects unable to provide written informed consent
2. Subjects who are pregnant or breast-feeding
3. Subjects who have had previous surgery to the breast
4. Subjects who have previously received chemotherapy or radiotherapy to the breast
5. Subjects who have had a breast biopsy less than two weeks prior to imaging
6. Subjects with any active or metallic implant (e.g. cardiac pacemaker, stents, internal cardiac defibrillator, cardiac resynchronisation device, nerve stimulator…), or subjects bearing any non-removable metallic object (e.g. piercing) on their torso
7. Post-biopsy patients whose breast tissue is not healed sufficiently for the imaging procedure, in the opinion of the investigator
8. Patients who have had or plan to have a breast cyst aspiration before MBI.
9. Subjects with significant co-morbidities which, in the opinion of the investigator, may influence the result of the study
10. Subjects with prior or concurrent malignancy
11. Subjects under the age of 18 years old
12. Subjects with evidence of inflammation and/or erythema of the breast as well as any subjects who have a break in the skin which would be in contact with the coupling fluid
13. Subjects who would be unsuitable for an MBI scan, unlikely to attend a follow up visit, or would otherwise be unsuitable for such an investigation, in the opinion of the Investigator
Minimum Eligible Age

18 Years

Eligible Sex

FEMALE

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

HRB Clinical Research Facility Galway

OTHER

Sponsor Role collaborator

MVG Industries SAS

INDUSTRY

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Responsibility Role SPONSOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Michael Kerin, Prof.

Role: PRINCIPAL_INVESTIGATOR

Galway University Hospital

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

HRB Clinical Research Facility Galway

Galway, , Ireland

Site Status

Countries

Review the countries where the study has at least one active or historical site.

Ireland

Provided Documents

Download supplemental materials such as informed consent forms, study protocols, or participant manuals.

Document Type: Study Protocol and Statistical Analysis Plan

View Document

Related Links

Access external resources that provide additional context or updates about the study.

http://www.mvg-world.com/en

The manufacturer of the trialed investigational medical device and sponsor of the clinical investigation

http://www.nuigalway.ie/hrb_crfg/

The investigational site

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

TN.32.1.17.SATF

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

Study of Monochromatic X-ray Mammography System
NCT07219797 NOT_YET_RECRUITING NA
NearWave Optical Molecular Monitoring
NCT06744465 RECRUITING NA