coMparison Between invAsive and Non-invasive assessmenT on Blood Pressure and Cardiac Function in HealthY Participants

NCT ID: NCT03372616

Last Updated: 2017-12-13

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

UNKNOWN

Total Enrollment

100 participants

Study Classification

OBSERVATIONAL

Study Start Date

2018-01-31

Study Completion Date

2018-06-30

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

This is a cross-sectional cohort study which aims to compare the invasive and non-invasive assessments on aortic blood pressure and cardiac funtion in subjects without history of cardio-vascular disease. Left ventricular (LV) filling pressure, LV volume, and aortic blood pressure will be measured invasively. Non-invasive assessment includes echocardiography,aortic, and carotid blood pressure measurement.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Healthy Volunteer

Keywords

Explore important study keywords that can help with search, categorization, and topic discovery.

aortic blood pressure diastolic dysfuntion echocardiography left ventricular ejection fraction

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Observational Model Type

COHORT

Study Time Perspective

CROSS_SECTIONAL

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

All participants

Aortic blood pressure, LV filling pressrue, and LV volume will be measured in all participants. Meanwhile, echocardiography and non-invasive aortic blood presure measurement will be performed. Three devices will be used in non-invasive aortic blood presure measurement, including Sphygmocor (AtCor Medical, Australia), PulsePen (DiaTecne SRL, Italy), and Mobil-O-Graph (IEM, Germany). In conclusion, all participants will receive invasive and non-invasive left ventricular diastolic function assessment, together with invasive and non-invasive aortic blood pressure assessment.

Invasive left ventricular diastolic function assessment

Intervention Type DIAGNOSTIC_TEST

Left ventricular (LV) polyethylene catheter was inserted into left ventricular to directly measure LV filling pressure.

Invasive aortic blood pressure measurement

Intervention Type DIAGNOSTIC_TEST

Aortic blood pressure will be measured with polyethylene catheter in aortic root.

Non-Invasive left ventricular diastolic function assessment

Intervention Type DIAGNOSTIC_TEST

Echocardiography will be performed in all participants to assess left ventricular diastolic function non-invasively.

Non-Invasive aortic blood pressure measurement

Intervention Type DIAGNOSTIC_TEST

Three devices (Sphygmocor \[AtCor Medical, Australia\], PulsePen \[DiaTecne SRL, Italy\], and Mobil-O-Graph \[IEM, Germany\] ) will be used to assess aortic blood pressure non-invasively when participants are undergoing invasive aortic blood pressure measurement.

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Invasive left ventricular diastolic function assessment

Left ventricular (LV) polyethylene catheter was inserted into left ventricular to directly measure LV filling pressure.

Intervention Type DIAGNOSTIC_TEST

Invasive aortic blood pressure measurement

Aortic blood pressure will be measured with polyethylene catheter in aortic root.

Intervention Type DIAGNOSTIC_TEST

Non-Invasive left ventricular diastolic function assessment

Echocardiography will be performed in all participants to assess left ventricular diastolic function non-invasively.

Intervention Type DIAGNOSTIC_TEST

Non-Invasive aortic blood pressure measurement

Three devices (Sphygmocor \[AtCor Medical, Australia\], PulsePen \[DiaTecne SRL, Italy\], and Mobil-O-Graph \[IEM, Germany\] ) will be used to assess aortic blood pressure non-invasively when participants are undergoing invasive aortic blood pressure measurement.

Intervention Type DIAGNOSTIC_TEST

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Over or equal to 18 years old;
* Agree to participate the study and sign informed written consent;
* Any change of drugs which effect the hemodynamics during 1 month prior to enrollment;
* Proposed to perform coronary angiography and left left ventriculography in hospital;

Exclusion Criteria

* Non-sinus rhythm or frequent extra systoles;
* Identified coronary artery disease via coronary angiography;
* Diagnosed pulmonary vascular or parenchymal disease;
* Hypertrophic cardiomyopathy, restrictive cardiomyopathy, or constrictive pericarditis;
* Stenosis or insufficiency of valves (moderate and above);
* Heart transplant;
* Congenital heart disease;
* Inadequate imaging or doppler parameter quality in echocardiography.
Minimum Eligible Age

18 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

Yes

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Shanghai 10th People's Hospital

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Ya-Wei Xu

Chief director of department of cardiology

Responsibility Role PRINCIPAL_INVESTIGATOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Yawei Xu, M.D., Ph.D.

Role: STUDY_CHAIR

Shanghai 10th People's Hospital

Central Contacts

Reach out to these primary contacts for questions about participation or study logistics.

Chen Chi, M.D.

Role: CONTACT

Phone: 086-150-2178-7802

Email: [email protected]

Yi Zhang, M.D., Ph.D.

Role: CONTACT

Phone: 086-189-1768-6332

Email: [email protected]

References

Explore related publications, articles, or registry entries linked to this study.

Nagueh SF, Smiseth OA, Appleton CP, Byrd BF 3rd, Dokainish H, Edvardsen T, Flachskampf FA, Gillebert TC, Klein AL, Lancellotti P, Marino P, Oh JK, Popescu BA, Waggoner AD. Recommendations for the Evaluation of Left Ventricular Diastolic Function by Echocardiography: An Update from the American Society of Echocardiography and the European Association of Cardiovascular Imaging. J Am Soc Echocardiogr. 2016 Apr;29(4):277-314. doi: 10.1016/j.echo.2016.01.011. No abstract available.

Reference Type BACKGROUND
PMID: 27037982 (View on PubMed)

Handoko ML, Paulus WJ. Polishing the diastolic dysfunction measurement stick. Eur J Echocardiogr. 2008 Sep;9(5):575-7. doi: 10.1093/ejechocard/jen181. Epub 2008 Jun 11. No abstract available.

Reference Type BACKGROUND
PMID: 18579489 (View on PubMed)

McEniery CM, Cockcroft JR, Roman MJ, Franklin SS, Wilkinson IB. Central blood pressure: current evidence and clinical importance. Eur Heart J. 2014 Jul;35(26):1719-25. doi: 10.1093/eurheartj/eht565. Epub 2014 Jan 23.

Reference Type BACKGROUND
PMID: 24459197 (View on PubMed)

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

MATCHY2017YZ

Identifier Type: -

Identifier Source: org_study_id