Technical Development of Cardiovascular Magnetic Resonance Imaging (CMR) Using a Low Specific Absorption Rate (SAR) Scanner System

NCT ID: NCT03331380

Last Updated: 2025-12-04

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

RECRUITING

Clinical Phase

NA

Total Enrollment

2950 participants

Study Classification

INTERVENTIONAL

Study Start Date

2018-01-05

Study Completion Date

2026-05-31

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

Background:

Researchers are testing version of a system known as a magnetic resonance imagining (MRI) scanner that uses strong magnetic fields, radio waves and the like to create images of the organs in the body. It uses lower energy levels than other MRI scanners. This may help scan people with metal devices in their body, or in invasive heart procedures using metal tools.

Objective:

To test a new MRI scanner and software changes to create better pictures.

Eligibility:

People with disease and healthy volunteers, ages 18 and older.

Design:

Participants will be screened with blood tests.

Participants may have both the new MRI and a conventional MRI or only the new one. If 2 are done, they must be within 60 days.

For both MRI versions, participants lie on a table that slides into a large tube. During scans, they will hold their breath for up to 20 seconds at a time. Heart activity will be measured by wires connected to pads on the skin. A flexible belt may be used to monitor their breathing. They will be in the scanner up to 2 hours.

Participants can agree to have a dye called gadolinium injected into their arm during the scan. This brightens the pictures.

Participants can agree to take a drug called a vasodilator. This helps detect areas of the heart with abnormal blood supply. Scans of the heart are taken before, during, and after they get the medicine. The drug may cause temporary chest pain or shortness of breath. They may get other drugs to relieve these symptoms.

Sponsoring Institution: National Heart, Lung, and Blood Institute

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Cardiac magnetic resonance imaging (CMR) provides accurate and reproducible measures of cardiac chamber volumes, cardiac function, blood flow, myocardial scar, myocardial extracellular volume as a measure of collagen content, myocardial iron content, and others, all without exposure to ionizing radiation. The prevailing wisdom is that CMR using high specific absorption rate (SAR) scanning modes produces highest image quality. We propose a method of CMR that can be performed with low SAR but that nevertheless preserves image quality because of efficient use of CMR signal. CMR using low SAR is attractive because it may reduce heating of metallic structures. This may allow safe CMR in patients with metallic implants, and it may allow MRI catheterization using metallic guidewires and catheter devices.

The goal of this non-significant risk (NSR) medical device study is to test initial technical feasibility of low SAR CMR in healthy volunteers by technical optimization of scanner protocols, to test comparative accuracy of standard CMR measurements in healthy volunteers using low SAR CMR versus conventional CMR, and to test comparative accuracy of standard CMR measurements in adult patients with known stable heart disease using low SAR CMR versus conventional CMR. A secondary goal is to assess the potential of this new low SAR CMR system to perform non-cardiovascular radiological diagnostic imaging by testing comparative diagnostic accuracy of standard MR measurements in adult patients with known non-cardiovascular disease using the low SAR CMR system vs conventional MR exam.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

CAD

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

NON_RANDOMIZED

Intervention Model

FACTORIAL

Primary Study Purpose

DIAGNOSTIC

Blinding Strategy

NONE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Group A

Group A includes 600 healthy adult volunteers of both sexes with-out known cardiovascular disease

Group Type OTHER

MRI scan - obj 1

Intervention Type DEVICE

For objective 1 (protocol optimization), healthy volunteers undergo imaging using an investigational low SAR CMR scanner for up to two hours, some without and some with administration of intravenous gadolinium based contrast agents (GBCAs).

MRI scans - obj 2

Intervention Type DEVICE

For objective 2 (comparative scanning of normals), healthy volunteers undergo two CMR examinations on two different MRI scanners (investigational low SAR CMR and conventional 1.5T CMR), some without and some with administration of intravenous GBCA.

Group B

Group B includes 500 adult subjects of both sexes with known sta-ble cardiovascular disease including adults with stable coronary artery disease after myocardial infarction; adults with heart failure and reduced left ventricular systolic function; adults with pulmonary artery hypertension; adults with congenital heart disease including cardiac shunts; adults with valvular heart disease including aortic stenosis, mitral regurgitation, and tricuspid regurgitation; and adults with metallic cardiovascular implants (such as coronary and peripheral artery stents) known to be safe for CMR at 1.5T

Group Type OTHER

MRI scans - obj 3

Intervention Type DEVICE

For objective 3 (comparative scanning of patients), subjects with known stable cardiovascular disease undergo two CMR examinations on two different MRI scanners (investigational low SAR CMR and conventional 1.5T CMR), some without and some with administration of intravenous GBCA.

Group C

Group C includes 500 adult subjects of both sexes with known non-cardiovascular disease

Group Type OTHER

MRI scans - obj 4

Intervention Type DEVICE

For objective 4 (comparative scanning of patients), subjects with known or suspected disease, including neurological, musculoskeletal disease, abdominal or lung disease, will undergo two MR examinations on two different MRI scanners (investigational low SAR CMR and conventional MR).

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

MRI scan - obj 1

For objective 1 (protocol optimization), healthy volunteers undergo imaging using an investigational low SAR CMR scanner for up to two hours, some without and some with administration of intravenous gadolinium based contrast agents (GBCAs).

Intervention Type DEVICE

MRI scans - obj 2

For objective 2 (comparative scanning of normals), healthy volunteers undergo two CMR examinations on two different MRI scanners (investigational low SAR CMR and conventional 1.5T CMR), some without and some with administration of intravenous GBCA.

Intervention Type DEVICE

MRI scans - obj 3

For objective 3 (comparative scanning of patients), subjects with known stable cardiovascular disease undergo two CMR examinations on two different MRI scanners (investigational low SAR CMR and conventional 1.5T CMR), some without and some with administration of intravenous GBCA.

Intervention Type DEVICE

MRI scans - obj 4

For objective 4 (comparative scanning of patients), subjects with known or suspected disease, including neurological, musculoskeletal disease, abdominal or lung disease, will undergo two MR examinations on two different MRI scanners (investigational low SAR CMR and conventional MR).

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Men and women age greater than or equal to 18 years
* Able to provide informed consent in writing
* Willingness to cooperate with all study procedures (including food restriction) and available for scheduled study events


-Currently healthy, self-reported


* Subjects having known heart disease including but not limited to
* Stable angina pectoris due to epicardial coronary artery obstruction
* Past myocardial infarction
* Heart failure with reduced ejection fraction
* Valvular heart disease
* Pulmonary artery hypertension
* Congenital heart disease with or without prior repair
* Myocarditis
* Infiltrative cardiomyopathy
* Hypertrophic cardiomyopathy


* Having known brain disease including but not limited to:

* Transient ischemic attack or stroke after 24 hours of onset
* Infection, inflammation meningitis
* Cognitive decline, neurodegenerative disorders
* Demyelinating disease, multiple sclerosis
* Loss of consciousness, seizures, epilepsy
* Brain tumor, metastases, abscess, lesion
* Vascular pathology
* Headache
* Hemorrhage
* Trauma
* Have known musculoskeletal disease including but not limited to:

* Persistent neck pain or radiculopathy
* Cancer or tumors of the spine
* Congenital abnormalities of the spinal cord or knee
* Multiple sclerosis
* Injury or trauma
* Fracture evaluation
* Infectious or inflammatory processes
* Soft tissue damage
* Muscle or tendon disorders
* Knee meniscal disorders
* Marrow abnormalities
* Mechanical knee symptoms
* Vascular conditions
* Have known abdominal diseases including but not limited to:

* Bowel obstruction
* Masses and tumors
* Crohns disease
* Diffuse liver disease such as hemochromatosis, hemosiderosis, fatty infiltration
* Focal hepatic lesions
* Cirrhotic liver
* Iron content determination
* Cystic kidney disease
* Vascular abnormalities
* Have known lung disease including but not limited to:

* Cancer, tumors and masses
* Vascular and lymphatic abnormalities
* Pulmonary thromboembolic disease
* Trauma
* Suspected bronchiolitis
* Bronchiectasis or pneumonitis
* Asthma and other obstructive lung diseases
* Pulmonary lymphangioleiomyomatosis
* Cystic and interstitial lung diseases such as pulmonary lymphangioleiomyomatosis and cystic fibrosis
* Have other known non-cardiovascular disease


\- Only subjects who use bronchodilators routinely or those have undergone previous pulmonary function testing with bronchodilators will be invited to undergo bronchodilator testing during MRI.

Exclusion Criteria

* Conditions that are thought to make MRI unsafe (that will be determined by filling out a separate form) including:

* Cerebral aneurysm clip unless it is labeled safe for MRI
* Neural stimulator (e.g. TENS-Unit) unless it is labeled safe for MRI
* Any type of ear implant unless it is labeled safe for MRI
* Ocular foreign body (e.g. metal shavings)
* Metal shrapnel or bullet
* Any implanted device (e.g. insulin pump, drug infusion device), unless it is labeled safe for MRI
* Pregnancy. When uncertain, subjects will undergo either urine or serum pregnancy testing. Results from up to 3 days prior to the examination will be used. Post-menopausal and surgically sterilized subjects are exempt from this testing.

* If a urine or serum pregnancy test was administered as part of a referral protocol, and the test was administered up to 3 days prior to MRI examination for this protocol, a new pregnancy test will not be required for this protocol.
* If a pregnancy test has not been administered within 3 days of MRI examination for this protocol, a serum or urine pregnancy test will be administered. Medical personnel will determine which pregnancy test is appropriate based on subject s medical history, screening, and individual scenario. In addition, the subject will be asked if she may be pregnant prior to the performance of the MRI, even if the pregnancy test was negative within the past week. The pregnancy test will be repeated if she answers in the affirmative.


-When gadolinium based contrast agent (GBCA) exposure is planned

* Objective 1 and 2, Healthy Volunteers: No gadolinium based contrast agent exposure is permitted if eGFR \< 60 mL/min/1.73m\^(2) using the CKD-EPI equation or equivalent and a serum creatinine measured within 2 weeks without intercurrent change in medical condition or medications.
* Objective 3 and 4, Volunteers with Cardiac and Non-Cardiac Disease: No gadolinium based contrast agent exposure is permitted if eGFR \< 30 mL/min/1.73m\^(2) using the CKDEPI equation \[25\] or equivalent and a serum creatinine measured within 2 weeks without

intercurrent change in medical condition or medications.

--For all objectives not more than two research MRI exams with GBCA exposure in a 12 month period. Research MRI exams performed outside of this protocol will be included in the 12 month period.

* Subjects meeting this exclusion criterion, or without eGFR determination, may still be included in the study but may not be exposed to gadolinium-based contrast agents
* Breast feeding (unless subject is willing to discard breast milk for 24 hours)
* Does not wish to be exposed to gadolinium.


* Severe chronic obstructive pulmonary disease defined as requiring more than one bronchodilator medication every day or continuous oxygen requiring
* Prior treatment with bleomycin


* A history of allergic reaction to any intravenous iron product
* Allergy to ferumoxytol or to mannitol excipient
* Breast feeding
* Does not wish to be exposed to ferumoxytol
* Iron overload


* A history of reaction to oral contrast (if using barium sulfate)
* Breast feeding unless subject is willing to discard breast milk for 24 hours (if using barium sulfate)
* Allergy to pineapple (if using pineapple juice)
* Does not wish to be exposed to oral contrast


-Important past medical illness


* Unstable angina, acute coronary syndrome, or myocardial infarction not attributable to PCI, within 2 weeks unless after coronary revascularization of the culprit lesion.
* Any hemodynamic instability or decompensated heart failure as determined by the enrolling physician.
* Adenosine: Patients with asthma or chronic obstructive pulmonary disease of any severity are ineligible for vasodilator stress CMR with adenosine.
* Regadenoson: Only patients with severe or uncontrolled asthma or severe or uncontrolled chronic obstructive pulmonary disease are ineligible for vasodilator stress CMR with regadenoson. This will be determined at the discretion of the supervising provider based on medical records and physical exam.
* Patients with advanced heart block on baseline ECG are ineligible for vasodilator stress CMR


* Acute illness for which investigational imaging might delay care (such as acute stroke before treatment), as determined by the enrolling physician
* Any hemodynamic instability as determined by the enrolling physician.


\- Patient refuses bronchodilator administration.


Low-SAR MRI:

* Subjects with MRI-conditional and legacy CIEDs are not excluded, based on the intrinsic safety of low-SAR MRI.
* Subjects with CIEDs are excluded if they have pacemakers implanted before 1998; ICDs implanted before 2000; temporary, epicardial or abandoned leads; and CIEDs implanted \<4 weeks prior to MRI exam.

Conventional MRI:

-Subjects with CIED are excluded from conventional MRI unless they have CIEDs that are labeled as MRI conditional or MRI safe, and that are implanted greater than or equal to 4 weeks prior to MRI.
Minimum Eligible Age

18 Years

Maximum Eligible Age

100 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

Yes

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

National Heart, Lung, and Blood Institute (NHLBI)

NIH

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Responsibility Role SPONSOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Adrienne E Campbell, Ph.D.

Role: PRINCIPAL_INVESTIGATOR

National Heart, Lung, and Blood Institute (NHLBI)

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

National Institutes of Health Clinical Center

Bethesda, Maryland, United States

Site Status RECRUITING

Countries

Review the countries where the study has at least one active or historical site.

United States

Central Contacts

Reach out to these primary contacts for questions about participation or study logistics.

Anastasia Tsakirellis, C.R.N.P.

Role: CONTACT

(301) 921-6986

Adrienne E Campbell, Ph.D.

Role: CONTACT

(301) 480-4080

Facility Contacts

Find local site contact details for specific facilities participating in the trial.

For more information at the NIH Clinical Center contact Office of Patient Recruitment (OPR)

Role: primary

800-411-1222 ext. TTY8664111010

References

Explore related publications, articles, or registry entries linked to this study.

Xiang J, Ramasawmy R, Seemann F, Peters DC, Campbell-Washburn AE. Balanced steady-state free precession phase contrast at 0.55T applied to aortic flow. J Cardiovasc Magn Reson. 2024 Winter;26(2):101098. doi: 10.1016/j.jocmr.2024.101098. Epub 2024 Sep 13.

Reference Type DERIVED
PMID: 39278416 (View on PubMed)

Campbell-Washburn AE, Jiang Y, Korzdorfer G, Nittka M, Griswold MA. Feasibility of MR fingerprinting using a high-performance 0.55 T MRI system. Magn Reson Imaging. 2021 Sep;81:88-93. doi: 10.1016/j.mri.2021.06.002. Epub 2021 Jun 8.

Reference Type DERIVED
PMID: 34116134 (View on PubMed)

Bandettini WP, Shanbhag SM, Mancini C, Henry JL, Lowery M, Chen MY, Xue H, Kellman P, Campbell-Washburn AE. Evaluation of Myocardial Infarction by Cardiovascular Magnetic Resonance at 0.55-T Compared to 1.5-T. JACC Cardiovasc Imaging. 2021 Sep;14(9):1866-1868. doi: 10.1016/j.jcmg.2021.02.024. Epub 2021 May 19. No abstract available.

Reference Type DERIVED
PMID: 34023254 (View on PubMed)

Bandettini WP, Shanbhag SM, Mancini C, McGuirt DR, Kellman P, Xue H, Henry JL, Lowery M, Thein SL, Chen MY, Campbell-Washburn AE. A comparison of cine CMR imaging at 0.55 T and 1.5 T. J Cardiovasc Magn Reson. 2020 May 18;22(1):37. doi: 10.1186/s12968-020-00618-y.

Reference Type DERIVED
PMID: 32423456 (View on PubMed)

Related Links

Access external resources that provide additional context or updates about the study.

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

18-H-0011

Identifier Type: -

Identifier Source: secondary_id

180011

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

Study of Blood Flow in Heart Muscle
NCT00001631 COMPLETED PHASE2
Radiation-Free Heart Catheterization Using MRI
NCT02739087 ACTIVE_NOT_RECRUITING NA
Imaging Techniques in MRI
NCT01130545 RECRUITING
Biomarkers and Cardiac CT
NCT02381301 RECRUITING