Effects of Bright Light on Co-occurring Cancer-related Symptoms in Breast Cancer Survivors
NCT ID: NCT03304587
Last Updated: 2025-06-10
Study Results
Outcome measurements, participant flow, baseline characteristics, and adverse events have been published for this study.
View full resultsBasic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
NA
30 participants
INTERVENTIONAL
2017-11-06
2022-08-31
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Bright Light on Fatigue in Women Being Treated for Breast Cancer
NCT02658708
Systematic Light Exposure for Fatigue in Breast Cancer Patients
NCT03217201
Quality of Life in Female Breast Cancer Survivors and Their Spouse, Partner, or Acquaintance
NCT00309933
The Effects of Light Therapy to Treat Cancer-related Side Effects
NCT04418856
Mindfulness-based Stress Reduction (MBSR) Program Combined With Endurance Exercise Training: a Help in Treatment for Breast Cancer
NCT02900326
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Aim #1: To assess the feasibility of implementing a home-based, personalized bright light intervention and the proposed data collection plan in post-treatment survivors of breast cancer.
Aim #2: To estimate the effects of the personalized bright light intervention on sleep disturbance, fatigue, depression, cognitive dysfunction, and quality of life in survivors of breast cancer.
Aim #3: To estimate the effects of a personalized bright light intervention on circadian rhythms in survivors of breast cancer.
The participants of this randomized, controlled pilot study will be randomized to either 30-minute blue-green light therapy at 12,000 lux or dim red light control at 5 lux. Light will be self-administered using a light visor cap at home for 14 consecutive days. Tailored to the individual's circadian pattern, light will be delivered either within 30 minutes of waking in the morning or between 1900-2000 hours in the evening. The nocturnal sleep patterns will be monitored by all-night in-lab polysomnography; sleep quality, fatigue, depression, and quality of life will be self-reported; cognition will be objectively assessed before and after the intervention. Circadian rhythm will be indexed by nocturnal core body temperature before and after the intervention. Feasibility will be determined by the proportion of contacted, recruited, and retained subjects, and completeness of the data collected. Subjective feedback and burden will be assessed at study exit.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
RANDOMIZED
PARALLEL
SUPPORTIVE_CARE
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Arm 1: Bright blue-green light
* Bright blue-green light (\~515nm; 12,000 lux) for 30 minutes once a day.
* For those who have scores of ≤41 (evening types) on Horne-Ostberg Morningness-Eveningness Questionnaire (MEQ), light will be delivered within 30 minutes of waking for 14 consecutive mornings. For those who receive scores of ≥59 (morning types), light will be delivered between 1900-2000 hours for 14 consecutive evenings.
* Light therapy will be self-administered using a light visor cap
* Each participant will make (3) overnight visits to the sleep laboratory
* On 2 randomly selected days, the participants will wear a light meter during wake time
Polysomnography (PSG)
Sleep patterns will be measured by in-lab PSG following a standardized protocol. 10mm silver/silver chloride electroencephalogram (EEG) and electromyography (EMG) electrodes and 11mm silver/silver chloride electroculography (EOG) electrodes will be connected to a Nihon Kohden system, 912 model (Nihon Kohden, Irvine, CA). A standard sleep montage following the 10/20 procedure for electrode placement, left and right electrooculography referenced to the opposite mastoid and mentalis electromyography will be followed. Data will be visually scored by a polysomnographer blind to study conditions following the American Academy of Sleep Medicine (AASM) Manual.
Rectal thermistor 400 Series
Nocturnal core body temperature will be measured using a rectal thermistor 400 series manufactured by YSI (Yellow Springs, OH, USA) inserted up to a depth of 7 cm. and taped in place. The thermistor will be connected to a Model 4600 thermometer (YSI, Yellow Springs, OH, USA) that will be interfaced with the PSG via cabling. Core temperature readings will be continuously monitored and recorded every 5 minutes during the all-night sleep studies.
Bright blue-green light
-The cap visor-mounted device controls the distance of the light exposure, and positions the light source above eye level to target on the lower retina for better effect
Digital foot candle datalogging light meter
On 2 random days during the 2-week bright light treatment, ambient light will be recorded continuously during waking hours using a digital foot candle datalogging light meter (Extech Instruments, Waltham, MA) Model SDL400. The 7.1" x 2.9" x 1.0" light meter (12.21 oz) has the capacity to measure up to 10,000 footcandles (accuracy: ± 4% reading). The light-weight light sensor is approximately 2 inches in diameter and comes with a clip and strap that makes it comfortable to wear just below the neck.
Patient-Reported Outcomes Measurement Information System (PROMIS)-Cancer-Fatigue
8 items with a 5-point rating scale (1=not at all to 5 =very much) measuring fatigue experience and fatigue impact. Higher scores indicate worse fatigue. PROMIS-Fatigue was developed based on rigorous methodologies. The psychometric properties have been established across chronic illnesses including cancer.
PROMIS measures provide a common metric: the T-score (mean = 50, standard deviation = 10). A mean of 50 equals the mean in the U.S. general population.
Higher scores means more the attribute to be measures: e.g., for fatigue, sleep disturbance, depression, higher scores mean worse fatigue, worse sleep disturbance, worse depression.
But for physical function, higher scores mean better functioning.
Patient-Reported Outcomes Measurement Information System (PROMIS)-Sleep Disturbance
8 items with 5-point rating scales measuring overall sleep and sleep-related impairments. Higher scores indicate worse sleep disturbances. Validity was supported by moderate to high correlations with the existing scales, e.g. PSQI, Epworth Sleepiness Scale (ESS). The scores significantly differed participants with and without sleep disorders.
PROMIS measures provide a common metric: the T-score (mean = 50, standard deviation = 10). A mean of 50 equals the mean in the U.S. general population.
Higher scores means more the attribute to be measures: e.g., for fatigue, sleep disturbance, depression, higher scores mean worse fatigue, worse sleep disturbance, worse depression.
But for physical function, higher scores mean better functioning.
Patient-Reported Outcomes Measurement Information System (PROMIS)-Depression
8 items with 5-point rating scales (1=never to 5=always) measuring affective and cognitive manifestations of depressive mood. Higher scores indicate worse depression. In a sample of depressed outpatients, PROMIS-Depression showed greater reliability when compared to the CES-D and the Patient Health Questionnaire (PHQ-9). Convergent validity with the CES-D and PHQ-9 was supported by strong correlations, ranged 0.72 to 0.84
PROMIS measures provide a common metric: the T-score (mean = 50, standard deviation = 10). A mean of 50 equals the mean in the U.S. general population.
Higher scores means more the attribute to be measures: e.g., for fatigue, sleep disturbance, depression, higher scores mean worse fatigue, worse sleep disturbance, worse depression.
But for physical function, higher scores mean better functioning.
Patient-Reported Outcomes Measurement Information System (PROMIS)-Physical Function
8 items with 5-point rating scales measuring the individual's ability to complete daily activities. Higher scores indicate worse functioning. Validity was tested in 1,415 adults with diverse clinical conditions. The PROMIS Physical Function scores corresponded to the expected positive or negative changes in the individual's physical function.
PROMIS measures provide a common metric: the T-score (mean = 50, standard deviation = 10). A mean of 50 equals the mean in the U.S. general population.
Higher scores means more the attribute to be measures: e.g., for fatigue, sleep disturbance, depression, higher scores mean worse fatigue, worse sleep disturbance, worse depression.
But for physical function, higher scores mean better functioning.
Pittsburgh Sleep Quality Index (PSQI)
19 self-report items measuring sleep quality, latency, duration, efficiency, disturbance, medication use, and daytime dysfunction. Each item is rated on a 0-3 rating scale. The global PSQI score ranges 0-21, with higher scores indicating more severe sleep disturbance. A global PSQI score greater than 5 was found to have a sensitivity of 89.6% and a specificity of 86.5% in differentiating good and poor sleepers.
Center for Epidemiological Studies - Depression
20-item self-report instrument commonly used to measure depressive symptoms in cancer patients. Each item is rated on a 4-point rating scale (0=rarely or none of the time to 3=all of the time) describing the frequency of occurrence during the past week. Score can range from 0-60, with higher scores indicating more depressive symptoms.
Montreal Cognitive Assessment (MoCA)
The MoCA is highly sensitive for screening patient with mild cognitive impairment. The MoCA is a 30-point scale with 7 cognitive subtests: visuo-executive, naming, attention, language, abstraction, delayed recall, and orientation. It scores from 0 to 30, where higher scores indicate better cognition and a score below 26 indicates cognitive impairment. The MoCA is highly sensitive for screening patient with mild cognitive impairment.
European Organization for Research and Treatment of Cancer-Quality of Life Questionnaire (EORTC QLQ-C30)
The EORTC QLQ-C30 consists of 30 items with a 4-point rating scale (1=not at all to 4=very much) measuring functioning, symptom intensity, and global health status/quality of life during the past week.
Daily Log
-A log where the participants will indicate date, wake time, sleep time answer 3 questions regarding the previous nights sleep (answers range from 1=not at all to 5=very much), have an area to indicate if naps occurred during the day, and 2 questions about fatigue \& sleepiness (answers ranging from 0=no fatigue/sleepiness to 10=worst fatigue/sleepiness
Arm 2: Dim red light
* Dim red light (5 lux) (control group) for 30 minutes once a day.
--For those who have scores of ≤41 (evening types) on Horne-Ostberg Morningness-Eveningness Questionnaire (MEQ), light will be delivered within 30 minutes of waking for 14 consecutive mornings. For those who receive scores of ≥59 (morning types), light will be delivered between 1900-2000 hours for 14 consecutive evenings.
* Light therapy will be self-administered using a light visor cap
* Each participant will make (3) overnight visits to the sleep laboratory --On 2 randomly selected days, the participants will wear a light meter during wake time
Polysomnography (PSG)
Sleep patterns will be measured by in-lab PSG following a standardized protocol. 10mm silver/silver chloride electroencephalogram (EEG) and electromyography (EMG) electrodes and 11mm silver/silver chloride electroculography (EOG) electrodes will be connected to a Nihon Kohden system, 912 model (Nihon Kohden, Irvine, CA). A standard sleep montage following the 10/20 procedure for electrode placement, left and right electrooculography referenced to the opposite mastoid and mentalis electromyography will be followed. Data will be visually scored by a polysomnographer blind to study conditions following the American Academy of Sleep Medicine (AASM) Manual.
Rectal thermistor 400 Series
Nocturnal core body temperature will be measured using a rectal thermistor 400 series manufactured by YSI (Yellow Springs, OH, USA) inserted up to a depth of 7 cm. and taped in place. The thermistor will be connected to a Model 4600 thermometer (YSI, Yellow Springs, OH, USA) that will be interfaced with the PSG via cabling. Core temperature readings will be continuously monitored and recorded every 5 minutes during the all-night sleep studies.
Dim red light
-The cap visor-mounted device controls the distance of the light exposure, and positions the light source above eye level to target on the lower retina for better effect
Digital foot candle datalogging light meter
On 2 random days during the 2-week bright light treatment, ambient light will be recorded continuously during waking hours using a digital foot candle datalogging light meter (Extech Instruments, Waltham, MA) Model SDL400. The 7.1" x 2.9" x 1.0" light meter (12.21 oz) has the capacity to measure up to 10,000 footcandles (accuracy: ± 4% reading). The light-weight light sensor is approximately 2 inches in diameter and comes with a clip and strap that makes it comfortable to wear just below the neck.
Patient-Reported Outcomes Measurement Information System (PROMIS)-Cancer-Fatigue
8 items with a 5-point rating scale (1=not at all to 5 =very much) measuring fatigue experience and fatigue impact. Higher scores indicate worse fatigue. PROMIS-Fatigue was developed based on rigorous methodologies. The psychometric properties have been established across chronic illnesses including cancer.
PROMIS measures provide a common metric: the T-score (mean = 50, standard deviation = 10). A mean of 50 equals the mean in the U.S. general population.
Higher scores means more the attribute to be measures: e.g., for fatigue, sleep disturbance, depression, higher scores mean worse fatigue, worse sleep disturbance, worse depression.
But for physical function, higher scores mean better functioning.
Patient-Reported Outcomes Measurement Information System (PROMIS)-Sleep Disturbance
8 items with 5-point rating scales measuring overall sleep and sleep-related impairments. Higher scores indicate worse sleep disturbances. Validity was supported by moderate to high correlations with the existing scales, e.g. PSQI, Epworth Sleepiness Scale (ESS). The scores significantly differed participants with and without sleep disorders.
PROMIS measures provide a common metric: the T-score (mean = 50, standard deviation = 10). A mean of 50 equals the mean in the U.S. general population.
Higher scores means more the attribute to be measures: e.g., for fatigue, sleep disturbance, depression, higher scores mean worse fatigue, worse sleep disturbance, worse depression.
But for physical function, higher scores mean better functioning.
Patient-Reported Outcomes Measurement Information System (PROMIS)-Depression
8 items with 5-point rating scales (1=never to 5=always) measuring affective and cognitive manifestations of depressive mood. Higher scores indicate worse depression. In a sample of depressed outpatients, PROMIS-Depression showed greater reliability when compared to the CES-D and the Patient Health Questionnaire (PHQ-9). Convergent validity with the CES-D and PHQ-9 was supported by strong correlations, ranged 0.72 to 0.84
PROMIS measures provide a common metric: the T-score (mean = 50, standard deviation = 10). A mean of 50 equals the mean in the U.S. general population.
Higher scores means more the attribute to be measures: e.g., for fatigue, sleep disturbance, depression, higher scores mean worse fatigue, worse sleep disturbance, worse depression.
But for physical function, higher scores mean better functioning.
Patient-Reported Outcomes Measurement Information System (PROMIS)-Physical Function
8 items with 5-point rating scales measuring the individual's ability to complete daily activities. Higher scores indicate worse functioning. Validity was tested in 1,415 adults with diverse clinical conditions. The PROMIS Physical Function scores corresponded to the expected positive or negative changes in the individual's physical function.
PROMIS measures provide a common metric: the T-score (mean = 50, standard deviation = 10). A mean of 50 equals the mean in the U.S. general population.
Higher scores means more the attribute to be measures: e.g., for fatigue, sleep disturbance, depression, higher scores mean worse fatigue, worse sleep disturbance, worse depression.
But for physical function, higher scores mean better functioning.
Pittsburgh Sleep Quality Index (PSQI)
19 self-report items measuring sleep quality, latency, duration, efficiency, disturbance, medication use, and daytime dysfunction. Each item is rated on a 0-3 rating scale. The global PSQI score ranges 0-21, with higher scores indicating more severe sleep disturbance. A global PSQI score greater than 5 was found to have a sensitivity of 89.6% and a specificity of 86.5% in differentiating good and poor sleepers.
Center for Epidemiological Studies - Depression
20-item self-report instrument commonly used to measure depressive symptoms in cancer patients. Each item is rated on a 4-point rating scale (0=rarely or none of the time to 3=all of the time) describing the frequency of occurrence during the past week. Score can range from 0-60, with higher scores indicating more depressive symptoms.
Montreal Cognitive Assessment (MoCA)
The MoCA is highly sensitive for screening patient with mild cognitive impairment. The MoCA is a 30-point scale with 7 cognitive subtests: visuo-executive, naming, attention, language, abstraction, delayed recall, and orientation. It scores from 0 to 30, where higher scores indicate better cognition and a score below 26 indicates cognitive impairment. The MoCA is highly sensitive for screening patient with mild cognitive impairment.
European Organization for Research and Treatment of Cancer-Quality of Life Questionnaire (EORTC QLQ-C30)
The EORTC QLQ-C30 consists of 30 items with a 4-point rating scale (1=not at all to 4=very much) measuring functioning, symptom intensity, and global health status/quality of life during the past week.
Daily Log
-A log where the participants will indicate date, wake time, sleep time answer 3 questions regarding the previous nights sleep (answers range from 1=not at all to 5=very much), have an area to indicate if naps occurred during the day, and 2 questions about fatigue \& sleepiness (answers ranging from 0=no fatigue/sleepiness to 10=worst fatigue/sleepiness
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Polysomnography (PSG)
Sleep patterns will be measured by in-lab PSG following a standardized protocol. 10mm silver/silver chloride electroencephalogram (EEG) and electromyography (EMG) electrodes and 11mm silver/silver chloride electroculography (EOG) electrodes will be connected to a Nihon Kohden system, 912 model (Nihon Kohden, Irvine, CA). A standard sleep montage following the 10/20 procedure for electrode placement, left and right electrooculography referenced to the opposite mastoid and mentalis electromyography will be followed. Data will be visually scored by a polysomnographer blind to study conditions following the American Academy of Sleep Medicine (AASM) Manual.
Rectal thermistor 400 Series
Nocturnal core body temperature will be measured using a rectal thermistor 400 series manufactured by YSI (Yellow Springs, OH, USA) inserted up to a depth of 7 cm. and taped in place. The thermistor will be connected to a Model 4600 thermometer (YSI, Yellow Springs, OH, USA) that will be interfaced with the PSG via cabling. Core temperature readings will be continuously monitored and recorded every 5 minutes during the all-night sleep studies.
Bright blue-green light
-The cap visor-mounted device controls the distance of the light exposure, and positions the light source above eye level to target on the lower retina for better effect
Dim red light
-The cap visor-mounted device controls the distance of the light exposure, and positions the light source above eye level to target on the lower retina for better effect
Digital foot candle datalogging light meter
On 2 random days during the 2-week bright light treatment, ambient light will be recorded continuously during waking hours using a digital foot candle datalogging light meter (Extech Instruments, Waltham, MA) Model SDL400. The 7.1" x 2.9" x 1.0" light meter (12.21 oz) has the capacity to measure up to 10,000 footcandles (accuracy: ± 4% reading). The light-weight light sensor is approximately 2 inches in diameter and comes with a clip and strap that makes it comfortable to wear just below the neck.
Patient-Reported Outcomes Measurement Information System (PROMIS)-Cancer-Fatigue
8 items with a 5-point rating scale (1=not at all to 5 =very much) measuring fatigue experience and fatigue impact. Higher scores indicate worse fatigue. PROMIS-Fatigue was developed based on rigorous methodologies. The psychometric properties have been established across chronic illnesses including cancer.
PROMIS measures provide a common metric: the T-score (mean = 50, standard deviation = 10). A mean of 50 equals the mean in the U.S. general population.
Higher scores means more the attribute to be measures: e.g., for fatigue, sleep disturbance, depression, higher scores mean worse fatigue, worse sleep disturbance, worse depression.
But for physical function, higher scores mean better functioning.
Patient-Reported Outcomes Measurement Information System (PROMIS)-Sleep Disturbance
8 items with 5-point rating scales measuring overall sleep and sleep-related impairments. Higher scores indicate worse sleep disturbances. Validity was supported by moderate to high correlations with the existing scales, e.g. PSQI, Epworth Sleepiness Scale (ESS). The scores significantly differed participants with and without sleep disorders.
PROMIS measures provide a common metric: the T-score (mean = 50, standard deviation = 10). A mean of 50 equals the mean in the U.S. general population.
Higher scores means more the attribute to be measures: e.g., for fatigue, sleep disturbance, depression, higher scores mean worse fatigue, worse sleep disturbance, worse depression.
But for physical function, higher scores mean better functioning.
Patient-Reported Outcomes Measurement Information System (PROMIS)-Depression
8 items with 5-point rating scales (1=never to 5=always) measuring affective and cognitive manifestations of depressive mood. Higher scores indicate worse depression. In a sample of depressed outpatients, PROMIS-Depression showed greater reliability when compared to the CES-D and the Patient Health Questionnaire (PHQ-9). Convergent validity with the CES-D and PHQ-9 was supported by strong correlations, ranged 0.72 to 0.84
PROMIS measures provide a common metric: the T-score (mean = 50, standard deviation = 10). A mean of 50 equals the mean in the U.S. general population.
Higher scores means more the attribute to be measures: e.g., for fatigue, sleep disturbance, depression, higher scores mean worse fatigue, worse sleep disturbance, worse depression.
But for physical function, higher scores mean better functioning.
Patient-Reported Outcomes Measurement Information System (PROMIS)-Physical Function
8 items with 5-point rating scales measuring the individual's ability to complete daily activities. Higher scores indicate worse functioning. Validity was tested in 1,415 adults with diverse clinical conditions. The PROMIS Physical Function scores corresponded to the expected positive or negative changes in the individual's physical function.
PROMIS measures provide a common metric: the T-score (mean = 50, standard deviation = 10). A mean of 50 equals the mean in the U.S. general population.
Higher scores means more the attribute to be measures: e.g., for fatigue, sleep disturbance, depression, higher scores mean worse fatigue, worse sleep disturbance, worse depression.
But for physical function, higher scores mean better functioning.
Pittsburgh Sleep Quality Index (PSQI)
19 self-report items measuring sleep quality, latency, duration, efficiency, disturbance, medication use, and daytime dysfunction. Each item is rated on a 0-3 rating scale. The global PSQI score ranges 0-21, with higher scores indicating more severe sleep disturbance. A global PSQI score greater than 5 was found to have a sensitivity of 89.6% and a specificity of 86.5% in differentiating good and poor sleepers.
Center for Epidemiological Studies - Depression
20-item self-report instrument commonly used to measure depressive symptoms in cancer patients. Each item is rated on a 4-point rating scale (0=rarely or none of the time to 3=all of the time) describing the frequency of occurrence during the past week. Score can range from 0-60, with higher scores indicating more depressive symptoms.
Montreal Cognitive Assessment (MoCA)
The MoCA is highly sensitive for screening patient with mild cognitive impairment. The MoCA is a 30-point scale with 7 cognitive subtests: visuo-executive, naming, attention, language, abstraction, delayed recall, and orientation. It scores from 0 to 30, where higher scores indicate better cognition and a score below 26 indicates cognitive impairment. The MoCA is highly sensitive for screening patient with mild cognitive impairment.
European Organization for Research and Treatment of Cancer-Quality of Life Questionnaire (EORTC QLQ-C30)
The EORTC QLQ-C30 consists of 30 items with a 4-point rating scale (1=not at all to 4=very much) measuring functioning, symptom intensity, and global health status/quality of life during the past week.
Daily Log
-A log where the participants will indicate date, wake time, sleep time answer 3 questions regarding the previous nights sleep (answers range from 1=not at all to 5=very much), have an area to indicate if naps occurred during the day, and 2 questions about fatigue \& sleepiness (answers ranging from 0=no fatigue/sleepiness to 10=worst fatigue/sleepiness
Other Intervention Names
Discover alternative or legacy names that may be used to describe the listed interventions across different sources.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* 21 years of age or older 1-3 years post-completion of chemotherapy or/and radiation therapy for stage I-III breast cancer
* Experience ≥ 2 concurrent symptoms (fatigue, sleep disruption, depressive symptoms, and/or cognitive dysfunction as measured by 4 screening instruments)
* Be either phase advanced or delayed (morning or evening types by the Horne-Ostberg Morningness-Eveningness Questionnaire (MEQ) ≥59 or ≤41)
* Sighted
* Mentally competent to consent
* Able to understand English.
Exclusion Criteria
* Have metastatic cancer
* Engaged in shift work or travel across more than three time zones within 2 weeks prior to study
* Current diagnosis of seasonal affective disorder or substance abuse Current diagnosis of major Axis I psychiatric disorders (e.g. depressive disorders), neurological impairments, or muscular dystrophies
* Report severe depressive mood (Center for Epidemiological Studies Depression Scale (CES-D) \>24)
* Take prescribed sedative hypnotics or steroids Have eye conditions (glaucoma or retinal disease), problems triggered by bright light (e.g., migraine), or take photosensitizing medications (e.g., some porphyrin drugs, antipsychotics, antiarrhythmic agents)
21 Years
FEMALE
Yes
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
National Institute of Nursing Research (NINR)
NIH
Michigan State University
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Horng-Shiuann Wu
Associate Professor
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Horng-Shiuann Wu, PhD
Role: STUDY_CHAIR
Michigan State University College of Nursing
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Michigan State University
East Lansing, Michigan, United States
Countries
Review the countries where the study has at least one active or historical site.
References
Explore related publications, articles, or registry entries linked to this study.
Wu HS, Gao F, Davis JE, Given CW. Effects of chronotype-tailored bright light intervention on post-treatment symptoms and quality of life in breast cancer survivors. Support Care Cancer. 2023 Nov 17;31(12):705. doi: 10.1007/s00520-023-08157-9.
Wu HS, Gao F, Davis JE, Given CW. Effects of Chronotype-tailored Bright Light Intervention on Symptoms and Quality of Life in Breast Cancer Survivors. Res Sq [Preprint]. 2023 Aug 25:rs.3.rs-3286350. doi: 10.21203/rs.3.rs-3286350/v1.
Provided Documents
Download supplemental materials such as informed consent forms, study protocols, or participant manuals.
Document Type: Study Protocol
Document Type: Statistical Analysis Plan
Document Type: Informed Consent Form
Related Links
Access external resources that provide additional context or updates about the study.
Alvin J. Siteman Cancer Center at Barnes-Jewish Hospital and Washington University School of Medicine
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
201703147
Identifier Type: -
Identifier Source: org_study_id
More Related Trials