Influence of Mechanical Ventilation Modes on the Efficacy of Nebulized Bronchodilator
NCT ID: NCT03271905
Last Updated: 2019-05-21
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
UNKNOWN
NA
10 participants
INTERVENTIONAL
2017-04-10
2019-12-10
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Effectiveness of Routine Nebulization of Mucolytics and Bronchodilators During Mechanical Ventilation
NCT02159196
Effectiveness and Safety of Respiratory Training in the Prevention and Severity of COVID-19
NCT04326114
Evaluation of Aerosolized Drugs Deposition During Mechanical Ventilation
NCT02818270
Non-invasive Mechanical Ventilation as a Rescue Therapy to Relieve Dyspnea in Patients With Stable Severe COPD
NCT02012101
Dexmeditomedine Versus No Sedation in Management of Agitation in COPD Patients Receiving Noninvasive Ventilation
NCT05774145
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
2.1 Primary
• To evaluate the influence of mechanical ventilation modes in the efficacy of nebulized bronchodilator in ventilator dependent patients with obstructive pulmonary disease.
2.2 Secondary
* To compare regional ventilation distribution through Ventilation Surface Area (VSA) and Tidal Impedance Variation (TIV or ∆Z) by electrical impedance tomography (EIT) before, immediately after, after 1hour (h), 2h and 3h of nebulized bronchodilator in pressure controlled ventilation (PCV) with and without sedative drugs, and during pressure support ventilation (PSV).
* To compare the peak expiratory flow (PEF), change in End-Expiratory Lung Volume (dEELV), Respiratory Compliance (Crs) and Resistance (R), before, immediately after, after 1h, 2h and 3h of nebulized bronchodilator by monitoring airway pressure and EIT in ventilator modes PCV, with and without sedative drugs and PSV .
* To compare the ventilator modes on the VSA, ∆Z, PEF, dEELV and Crs after nebulized bronchodilator and the duration of its effects during mechanical ventilation.
* To compare two different level of PEEP during nebulized bronchodilator on PCV mode while the patient stay with sedative drugs.
3\. METHODS
3.1 Study design This is a randomized crossover, blinded clinical trial. The randomization procedure will be a simple randomization by random number table. In order to improve reliability, not transparent sealed envelopes for blind allocation will be used.
3.2 Local and study period This is a multicenter study that involve the following hospitals: Hospital Miguel Arraes - PE and Real Hospital Português de Beneficência em Pernambuco- PE. All hospitals are located in the metropolitan region of Recife, Pernambuco, Brazil and the study will be conducted from February 2016 to December 2019.
3.3 Sample The study population consist of patients with obstructive pulmonary disease admitted to intensive care unit for MV support who meet the inclusion criteria.
3.4 Sample size Patients will be identified by a daily telephone calls to the ICUs each morning for data collection. Potential candidate patients will be screened for inclusion and exclusinon criteria, after the identification of eligible patients. After consent is obtained, the research team goes to the ICU to start collecting data. The sample size will be calculated by statistical procedures after conducting a pilot study of 10 patients.
3.5 Technical procedures and tools for data collection
Prior to starting the intervention, clinical and demographic data will be collected according to the evaluation form, ( Appendix 2). After that, patients will be receive each of 4 interventions, with a minimum of 4 hours between bronchodilator administration to allow for washout.
3.5.1. Intervention Protocol 3.5.1.1. Step 1: Nebulization during Pressure Controlled Ventilation (PCV) Mode Initially the patient will be accessed when he still sedated. Two intervention will be done with a PCV mode in two different ways and the order of the procedures will be randomized.
One nebulization will be done with a standard PCV mode and parameters will be setted as follows: sufficient Δ pressure to maintain the patient's tidal volume (vt) at 6 / kg ideal weight, respiratory rate (RR) at 12 bpm, inspiratory time (Ti) up to 1 second, maintain Ti / Ttot 0.3 - 0.4 without causing dynamic AutoPEEP, decreasing waveform flow and PEEP level of 85% from static autoPEEP.
Other nebulization will be done also in PCV mode with same parameters, but the level of PEEP will be increased to 15 cmH2O. Between this two interventions will be given 4 hours for washout.
After this, we will talk to the medical staff to interrupt sedation, will be given 3 hour for wash out to start de Step 2.
3.5.1.2. Step 2: Nebulization During Pressure Support Ventilation (PSV) With a clinical progression of the patient, a 4th evaluation will be done on the first day when the patient achieve PSV mode. In this ventilation mode the patient will control the Ti, Ttot, RR and inspiratory flow so it will be set only one Δ pressure for the patient to support a Vt of 6 ml/kg. The lowest minimum value of Δ P is 10 cmH2O and the end of inspiratory phase will be determined by a decrease at 25% of the patient peak inspiratory flow.
3.5.2 Nebulization Protocol
Nebulized bronchodilator drugs will be Salbutamol Sulfate (aerolin nebulis) and ipratropium bromide (atrovent) diluted in a saline solution (saline 0.9%) in 3 ml. The vibrating Mesh nebulizer (Aeroneb Pro-X, Galway, Ireland) will be placed in the inspiratory circuit of the MV immediately before 'Y' piece using a 22 mm T adapter. The nebulizer is operated by an electric controller connected mains power. The vibrating Mesh produces aerosol with an average particle size of 5 μm and will remain on continuously until the end of nebulization.
If a heat moisture exchanger (HME) is used during mechanical ventilation, it must be removed from between the nebulizer and airway before nebulization so that it does not filter out and reduce aerosol delivered.
3.5.3 Evaluation by Electrical Impedance Tomography. TIE is a tool of obtaining transverse plane image of any section of the human body by means of low-power electric current. The image is obtained from the electric current or potential detected on the surface of the evaluated area, where each "pixel" image is its impedance or resistivity. Thus, when used in thoracic follow-up, the EIT is able to evaluate the aeration and ventilation of the patient through the following variables: distribution of regional lung ventilation by Tidal Impedance Variation (ΔZ), Ventilation Surface Area (VSA), Percentage of Recruitable Lung (PRLV), Change in End-Expiratory Lung Volume (dEELV) and Respiratory Compliance (Crs) .
Initially, to evaluate the acute pulmonary impact of nebulizer bronchodilator on different ventilatory modes, EIT will be be performed before and immediately after the aerosol administration and repeated with each ventilation mode. Furthermore, the duration of nebulization effect will be evaluated by performing EIT after 1, 2 and 3h in each ventilation mode. There will be a \> 4 hour washout between bronchodilator administrations.
An impedance tomography (ENLIGHTER, Timpel, Brazil) will be used with the patient in supine position with a bed elevation of 45◦, so a belt with 32 electrodes will be applied to the chest, in the position corresponding to the 4th - 5th intercostal space on a shaved skin. Electrodes have to be positioned for reading electrocardiograms and a flow sensor that should be attached to the endotracheal tube. After this procedures recording data starts for 3 minutes.
For image acquisition, harmless electrical currents (5-8 nA, 125 KHz) will be injectates through electrode pairs in rotating sequence, and the potential differences Will be captured in other non injetantes electrode. Variations in thoracic impedance will be evaluated through a LabView software (National Instruments, USA) and the data is recorded in separate files for patients for further analysis.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
RANDOMIZED
CROSSOVER
TREATMENT
TRIPLE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Pressure-controled-ventilation (PCV)
Nebulization during mechanical ventilation on a pressure controled ventilation mode.
salbutamol sulfate and ipratropium bromide
Nebulization with salbutamol sulfate and ipratropium bromide during mechanical ventilation.
Mesh nebulization
Nebulization with Mesh device.
PCV and high PEEP
Nebulization during mechanical ventilation on a pressure controled ventilation mode and PEEP = 15 cmH2O.
salbutamol sulfate and ipratropium bromide
Nebulization with salbutamol sulfate and ipratropium bromide during mechanical ventilation.
Mesh nebulization
Nebulization with Mesh device.
Pressure suport ventilation (PSV)
Nebulization during mechanical ventilation on a pressure suport ventilation mode.
salbutamol sulfate and ipratropium bromide
Nebulization with salbutamol sulfate and ipratropium bromide during mechanical ventilation.
Mesh nebulization
Nebulization with Mesh device.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
salbutamol sulfate and ipratropium bromide
Nebulization with salbutamol sulfate and ipratropium bromide during mechanical ventilation.
Mesh nebulization
Nebulization with Mesh device.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
Exclusion Criteria
Contraindicated disconnection of the MV
Endotracheal tube diameter less than 7.5
Do not make part of the protocol of daily sedation
No regular ventilatory drive when with out sedation
Do not reach a minimum tidal volume 6 ml/kg with a maximum peak pressure (PIP) of 35 cmH2O (centimeter of water) during MV.
Do not use the same MV modes that will be tested in this study
18 Years
80 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Universidade Federal do Rio Grande do Norte
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Cibelle Andrade Lima
Principal Investigator
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Cibelle Andrade Lima
Recife, Pernambuco, Brazil
Countries
Review the countries where the study has at least one active or historical site.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
CibelleAndrade
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.