Intramural Needle Ablation for the Treatment of Refractory Ventricular Arrhythmias
NCT ID: NCT03204981
Last Updated: 2021-10-12
Study Results
Outcome measurements, participant flow, baseline characteristics, and adverse events have been published for this study.
View full resultsBasic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
NA
52 participants
INTERVENTIONAL
2017-10-17
2021-04-20
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Intramural Needle Ablation for Ablation of Recurrent Ventricular Tachycardia
NCT01791543
Early Ablation Therapy for the Treatment of Ischemic Ventricular Tachycardia in Patients With Implantable Cardioverter Defibrillators
NCT01557842
Real-Time Intracardiac Echocardiography for Ventricular Arrhythmia Ablation
NCT07201506
REnal Sympathetic dEnervaTion as an a Adjunct to Catheter-based VT Ablation
NCT01858194
Functional Substrate-Only Guided VT Ablation
NCT06464315
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
A variety of techniques, including electroanatomic mapping and activation, entrainment, and substrate mapping, are employed during electrophysiologic (EP) study to identify areas of myocardial scar and potential isthmus sites. Points or lines of ablation using RF energy are then created in an attempt to interrupt the reentry circuit. Typically, RF energy is applied via a catheter tip electrode to the endocardial or epicardial surface of the heart and grounded via an electrode pad placed on the patient's skin. RF energy in this setting is dispersed through the entirety of the tissue between catheter tip and grounding pad. The standard 7-French, 4-mm tip catheters are highly successful at ablating circuits located within a few millimeters of the catheter tip. A focal, 1mm area of resistive heating occurs within the myocardium immediately in contact with the catheter tip; myocardial cell death occurs several millimeters more deeply through passive, conductive heating, which spreads outward from the contact point.
While the standard catheter is effective at the ablation of superficial arrhythmias, it has proven more problematic when used for deep myocardial sites or for creating transmural lesions. A number of alternatives have been developed in an attempt to access these sites. 8-mm or 10-mm catheter tips are able to create larger zones of resistive heating, delivering direct RF energy to a larger area of myocardium. A larger interface between catheter tip and blood improves cooling and allows for the delivery of more power without a rise in impedance.The clinical use of these larger catheters can, however, be limited by rapid temperature rises at the catheter-tissue interface, resulting in thrombus formation, char, and "steam pop" rupture of the endocardial surface. The use of irrigated ablation catheters have improved upon the ability to deliver RF energy without a sustained rise in impedance. Both open irrigated- and closed-loop irrigated catheters circulate saline along the catheter tip-myocardial interface, allowing for continued delivery of RF current without thrombus formation at the endocardial surface. Intramyocardial temperature rises accordingly without a concomitant endocardial temperature surge, creating larger and deeper myocardial ablation zones. Transcoronary ethanol ablation has also been employed with moderate success in patients with arrhythmias resistant to endocardial catheter ablation.This technology, however, grants only limited control over the size of the resulting infarct and is restricted by the need for perfusion of the scar zone by an accessible coronary artery.
Nevertheless, there remain occasions in which an arrhythmia cannot be eliminated by standard ablation techniques. This is seen most frequently due to deep intramural ventricular tachycardia, sometimes encountered following myocardial infarction. Both standard and alternative ablation strategies are frequently either unavailable or inadequate for termination of these arrhythmias.
Initial experience with an electrically active needle electrode have demonstrated that radiofrequency ablative energy can effectively create lesions of homogeneous necrosis. Needle electrodes have been used experimentally from the epicardial surface, from the endocardium ex vivo and in vivo in an internally irrigated form. It has been shown that the use of a narrow-gauge non-irrigated endocardial needle ablation catheter creates very narrow but deep lesions due to the small electrode size. Catheters featuring a retractable needle tipped electrode with intramyocardial saline infusion have also shown promise as a means of accessing deep myocardial circuits in ventricular tachycardia ablation.18
The proposed study will further examine the role of INA in patients with ventricular arrhythmias resistant to standard ablation techniques.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NA
SINGLE_GROUP
DIAGNOSTIC
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Intramural Needle Ablation
Intramural Needle Ablation
The needle-tipped ablation catheter that will be used for the IN ablation uses radiofrequency like a standard RF ablation catheter, but delivers energy through an extendable/retractable needle.
Ablation
standard ablation
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Intramural Needle Ablation
The needle-tipped ablation catheter that will be used for the IN ablation uses radiofrequency like a standard RF ablation catheter, but delivers energy through an extendable/retractable needle.
Ablation
standard ablation
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* ≥ 15 years of age.
* Left ventricular (LV) ejection fraction \> 10% as estimated by echocardiography, contrast ventriculography or radionuclide imaging within the past 90 days.
* Clinical indication for catheter ablation of VT
* Intramural ventricular arrhythmias not terminable with standard ablation once enrolled in the Intramural Needle Ablation study or previous failed ablation within 6 months prior to enrollment.
* Ability to understand the requirements of the study and sign the informed consent form.
* Able and willing to comply with all pre-, post-, and follow-up testing and requirements.
* Projected lifespan greater than 1 year.
Exclusion Criteria
* NYHA Class IV CHF.
* Patients with idiopathic ventricular arrhythmias defined as VT or PVCs that occur without evidence of structural heart disease and that are not causing significant depression of LV function.
* Women known to be pregnant or to have positive beta-HCG.
* Definite protruding left ventricular thrombus on pre-ablation echocardiography or other imaging modalities.
* Contraindication to heparin
* Allergy to radiographic contrast dye.
* Unstable angina that is not due to frequent or incessant VT.
* Acute non-cardiovascular illness or systemic infection.
* Thrombocytopenia (platelet count \< 50,000 mm3) or coagulopathy.
* Cardiogenic shock unless it is due to incessant VT.
* Unable to sign consent.
* Projected lifespan of \< 1 year.
15 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Biosense Webster, Inc.
INDUSTRY
Vivek Reddy
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Vivek Reddy
Professor
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Vivek Reddy, MD
Role: PRINCIPAL_INVESTIGATOR
Icahn School of Medicine at Mount Sinai
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Icahn School of Medicine at Mount Sinai
New York, New York, United States
Countries
Review the countries where the study has at least one active or historical site.
References
Explore related publications, articles, or registry entries linked to this study.
Tedrow UB, Kurata M, Kawamura I, Batnyam U, Dukkipati S, Nakamura T, Tanigawa S, Fuji A, Richardson TD, Kanagasundram AN, Koruth JS, John RM, Hasegawa K, Abdelwahab A, Sapp J, Reddy VY, Stevenson WG. Worldwide Experience With an Irrigated Needle Catheter for Ablation of Refractory Ventricular Arrhythmias: Final Report. JACC Clin Electrophysiol. 2023 Aug;9(8 Pt 2):1475-1486. doi: 10.1016/j.jacep.2023.05.014. Epub 2023 May 19.
Dukkipati SR, Nakamura T, Nakajima I, Oates C, Narui R, Tanigawa S, Sljapic T, Whang W, Koruth JS, Choudry S, Schaeffer B, Fujii A, Tedrow UB, Sapp JL, Stevenson WG, Reddy VY. Intramural Needle Ablation for Refractory Premature Ventricular Contractions. Circ Arrhythm Electrophysiol. 2022 May;15(5):e010020. doi: 10.1161/CIRCEP.121.010020. Epub 2022 Apr 27.
Provided Documents
Download supplemental materials such as informed consent forms, study protocols, or participant manuals.
Document Type: Study Protocol and Statistical Analysis Plan
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
GCO 17-1899
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.