Low Vision Patients' Preference for Colored Filters and Illumination for Near Reading Determined by the LuxIQ/2

NCT ID: NCT03192722

Last Updated: 2024-03-29

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Clinical Phase

NA

Total Enrollment

42 participants

Study Classification

INTERVENTIONAL

Study Start Date

2017-04-20

Study Completion Date

2023-05-31

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

The effect of tinted filters and illumination on the visual performance of patients with low vision (i.e., individuals with reduced vision that is uncorrectable with glasses, surgery or treatments) has been a topic of research and discussion for many years, yet there is no current consensus or practice standard for the evaluation and recommendation of colored filters and/or illumination intensity. Anecdotally, there have been many subjective reports of improvement in visual function and comfort with the use of tinted lenses. Previous studies have attempted to elucidate the subjective improvements observed using vision tests, such as visual acuity and contrast sensitivity, and the findings have been inconsistent. Traditionally, filters and optimal illumination are prescribed clinically through a trial and error method, which involves trying various filters and lamps haphazardly to determine which if any are preferred by the patient. The investigators are proposing to evaluate whether the illumination and filters chosen in office by participants using a new assessment tool the LuxIQ/2 translate to overall patient comfort and improved speed, accuracy and print size while reading, and to evaluate whether participants have the same illumination and colored filter preference determined by the LuxIQ/2 in a clinical office setting and in their home environment. The investigators will evaluate whether participants prefer lighting determined by the new assessment tool the LuxIQ/2 in comparison to lighting determined by the OttLite Cobra in office.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

All eligible patients with complaints of difficulty performing sustained reading tasks, such as reading books or magazines, will be evaluated for their preference for filter color and lighting using the LuxIQ/2.

Baseline distance visual acuity, contrast sensitivity, and near visual acuity, will be evaluated during initial presentation to the clinic as part of usual care using validated tests that are routinely performed during a low vision examination. Best-corrected distance visual acuity will be determined using the ETDRS (Early Treatment for Diabetic Retinopathy Study) chart. Contrast sensitivity will be evaluated using the MARS contrast sensitivity chart. Best-corrected near visual acuity will be evaluated using the Lighthouse Continuous Text Card. The LuxIQ/2 will be administered 3 times at 15-minute intervals. Lighting preferences will be evaluated 3 times using the Ott Lite Cobra. Each subject will be asked to choose between their preferred lighting conditions as determined by the OttLite Cobra and the LuxIQ/2, i.e each participant ill choose which lighting conditions is preferred for reading. The assessment tool (OTTLite Cobra or LuxIQ/2) which is performed first will be randomized for each participant. Microperimetry (a type of visual field test) will be conducted on all participants using the MAIA microperimeter at the NSU site only.

For subjects who do not appreciate an improvement in reading ability with a colored filter in office, we will obtain their written informed consent to include data collected during the clinical examination. For participants who do not appreciate an improvement in reading ability with a colored filter, but who appreciate an improvement in reading ability with white light as determined by the LuxIQ/2 in comparison to the OttLite Cobra, appropriate light bulb and desk lanp will be provided as determined by the LuxIQ/2. For participants who prefer the lighting determined using the Ottlite Cobra, they will be provided with an Ottlite Cobra desk lamp as well as their preferred settings on the device as determined through the in-office evaluation to be used at home. Participants to whom light bulb recommendations were provided or the Ottlite Cobra was recommended to improve lighting for their reading tasks, will be contacted by a research assistant 1 week after the in office assessment to complete a telephone interview which will consist of an Activity inventory questionnaire which will inquire about their difficulty performing near tasks using their previous light source as well as Ramulu's sustained reading test. The Ramulu sustained reading test will be performed twice during the phone interview, once with their previous lighting they were using at home before they obtained the new reading lamp (where they do most of their reading) and again with their new desk lamp. After 1 month, the research assistant will call the participant to repeat the Activity questionnaire inquiring about ability to perform near tasks using the new recommended lighting.

For participants who appreciate an improvement in reading ability with colored reading glasses, we will obtain their written informed consent to join the longer-term study.

* Reading materials will be provided to participants in an enclosed envelope in office. Participants will be asked to refrain from opening envelope until contacted by research assistant. Other individuals who decide to participate at a later time after contemplating the requirements of the research, will be sent the reading material in the mail.
* A research assistant will contact subject 1 week after in office assessment to complete telephone interview which will consist of the reading domain of the Activity Inventory questionnaire and the modified Telephone Interview of Cognitive Status (TICS-M) and silent reading test. During the call, subject will be asked to read several pages of a short story to themselves, silently using their current reading glasses, not the new ones that will be ordered. Subjects will be asked to answer a few questions about the stories. This call should take about 30-60 minutes.
* Subjects will be provided with new prescription clear reading glasses. After 1 month a research assistant will contact participant to repeat the same questionnaires and silent reading test using a different short story.
* Within a month after the phone questionnaires, the PI will make an appointment to come to the subject's home to test near vision and contrast sensitivity and determine preference for filter in home environment. At this time, the PI may ask for the new pair of clear reading glasses to take them to our optical to tint the lenses to the color that is preferred by the subject.
* One group will obtain near vision glasses with color filter/tinted lenses immediately, while the other group (controls) will continue to wear the clear reading glasses for another 4 weeks and will then will crossover to obtain near vision glasses with the filter/tinted lenses.
* About a month after wearing near reading glasses with the colored lenses, one of our research assistants will call participant to repeat the same questionnaires and silent reading test again using a different short story. This call should take about 30-45 minutes.
* At the end a low vision optometrist on the research team will contact participants to ask some open-ended questions about what the participant thought about using the near reading glasses with the colored lenses. This call should take about 15-30 minutes.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Ocular Conditions Resulting in Visual Impairment

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

RANDOMIZED

Intervention Model

PARALLEL

Primary Study Purpose

OTHER

Blinding Strategy

NONE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Immediate exposure to near vision glasses with filters

Participants immediately provided with near vision glasses with colored filters

Group Type EXPERIMENTAL

Colored near reading glasses

Intervention Type DEVICE

Participants are provided with colored near vision glasses.

Delayed exposure to near vision glasses with filters

Participants provided with near vision glasses with colored filters after 8 weeks of wearing clear near vision glasses

Group Type OTHER

Colored near reading glasses

Intervention Type DEVICE

Participants are provided with colored near vision glasses.

Immediate exposure to LuxIQ/2

Participants are examined with LuxIQ/2 to determine preferred lighting as determined by device followed by examination with OttLite Cobra

Group Type OTHER

Lighting as determined by LuxIQ/2 or OttLite Cobra

Intervention Type DEVICE

Participants are provided preferred lighting (either OttLite or lamp with findings from LuxIQ/2)

Immediate exposure to OttLite Cobra

Participants are examined with OttLite Cobra to determine preferred lighting followed by LuxIQ/2

Group Type OTHER

Lighting as determined by LuxIQ/2 or OttLite Cobra

Intervention Type DEVICE

Participants are provided preferred lighting (either OttLite or lamp with findings from LuxIQ/2)

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Colored near reading glasses

Participants are provided with colored near vision glasses.

Intervention Type DEVICE

Lighting as determined by LuxIQ/2 or OttLite Cobra

Participants are provided preferred lighting (either OttLite or lamp with findings from LuxIQ/2)

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Subjects who express a desire to obtain filters in a pair of near reading glasses
* Age 18 and older
* Provide informed consent
* Complaints of difficulty performing sustained reading tasks, such as reading books or magazines
* Patients who are interested in obtaining preferred filters in a pair of reading glasses
* Patients who have completed an evaluation in the low vision service of the NSU The Eye Care Institute or Lighthouse of Broward or UCLA Stein Eye Institute

Exclusion Criteria

* Subjects with a score less than 21 on the TICS-M
* Subjects diagnosed with Dry Eye Syndrome determined by clinical signs, history of or current topical prescription medication (i.e., Restasis or Xiidra) usage, or the usage of other dry eye treatment including punctal plugs, instillation of artificial tears more than once per day and advanced dry eye treatment
* Subjects with poor vision who would require electronic magnification or non-visual devices
* Patients with poor vision for whom clinical management strategy would not involve tinted reading glasses and a lamp
Minimum Eligible Age

18 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Nova Southeastern University

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

So Yeon Lee

Assistant Professor

Responsibility Role PRINCIPAL_INVESTIGATOR

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Nova Southeastern University

Fort Lauderdale, Florida, United States

Site Status

Countries

Review the countries where the study has at least one active or historical site.

United States

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

2017-512

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

Patient Reported Outcomes With WaveLight Plus LASIK