Evaluation of the Accuracy and Precision of Flash Glucose Monitoring Sensors in Different Sites

NCT ID: NCT03154060

Last Updated: 2017-08-07

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Clinical Phase

NA

Total Enrollment

23 participants

Study Classification

INTERVENTIONAL

Study Start Date

2017-05-19

Study Completion Date

2017-08-04

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

On the first of July 2016, reimbursement for the Freestyle Libre Flash Glucose Monitoring (FGM) was introduced by the Belgian healthcare authority by means of a new diabetes convention. Making this the only way to receive the device in Belgium. Since then, many type 1 diabetes (T1D) patients switched to FGM. But some patients found the sensor on the upper arm too visible. Abbott does not recommend to place the sensor on a different place of the body than the back of the upper arm, because no tests were done yet (besides on the upper arm) to make an accuracy claim. With this study, we want to evaluate the accuracy and the precision of the Freestyle Libre FGM by using three FGM sensors simultaneously on different places of the body and perform regular self-monitoring of blood glucose (SMBG) tests.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Diabetes Mellitus, Type 1

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

NA

Intervention Model

SINGLE_GROUP

open-label, prospective, single-arm study
Primary Study Purpose

OTHER

Blinding Strategy

NONE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Intervention

Using 3 Abbott FreeStyle Libre Flash Glucose Monitoring sensors in parallel and measure 7 times a day BG by capillary finger stick testing.

Group Type EXPERIMENTAL

Abbott FreeStyle Libre Flash Glucose Monitoring sensors

Intervention Type DEVICE

Three FGM sensors will be inserted simultaneously (one on the back of the upper arm, abdomen and thigh) and will be worn for a consecutive 14 days. Throughout the study, patients should measure capillary blood glucose (BG) with the built-in BG meter of the Freestyle Libre at least 7 times per day (before and 1-2 hours after every meal and before bedtime). Additionally, patients should scan each sensor at least every 8 hours to obtain every measured interstitial glucose value. At the end visit (after 14 days), patients will come back to the hospital to download FGM and SMBG data.

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Abbott FreeStyle Libre Flash Glucose Monitoring sensors

Three FGM sensors will be inserted simultaneously (one on the back of the upper arm, abdomen and thigh) and will be worn for a consecutive 14 days. Throughout the study, patients should measure capillary blood glucose (BG) with the built-in BG meter of the Freestyle Libre at least 7 times per day (before and 1-2 hours after every meal and before bedtime). Additionally, patients should scan each sensor at least every 8 hours to obtain every measured interstitial glucose value. At the end visit (after 14 days), patients will come back to the hospital to download FGM and SMBG data.

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Patients with a diagnosis of T1D for more than 6 months
* Adult patients ≥ 18 years
* Signed informed consent form

Exclusion Criteria

* Pregnancy
* Patients with severe cognitive dysfunction or other disease which makes FGM use difficult.
* History of allergic reaction to any of the FGMs materials or adhesives when in contact with the skin.
* History of allergic reaction to chlorhexidine or alcohol anti-septic solution.
* Abnormal skin at the anticipated glucose sensor insertion sites (excessive hair, burn, inflammation, infection, rash, and/or tattoo).
* Presence of concomitant pathology that might cause edema at the insertion sites (such as heart failure, liver failure, kidney failure defined as eGFR \< 45 ml/min).
Minimum Eligible Age

18 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Onze Lieve Vrouwziekenhuis Aalst

OTHER

Sponsor Role collaborator

Universitaire Ziekenhuizen KU Leuven

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

prof dr Pieter Gillard

Professor Doctor Pieter Gillard

Responsibility Role PRINCIPAL_INVESTIGATOR

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Onze-Lieve-Vrouwziekenhuis Aalst

Aalst, , Belgium

Site Status

UZ Leuven

Leuven, , Belgium

Site Status

Countries

Review the countries where the study has at least one active or historical site.

Belgium

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

OOS-60146

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.