Microfidelity (MIFI) Ablation Technology Versus Standard Ablation Catheter for Atrioventricular Nodal Ablation
NCT ID: NCT03114124
Last Updated: 2021-09-22
Study Results
Outcome measurements, participant flow, baseline characteristics, and adverse events have been published for this study.
View full resultsBasic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
NA
30 participants
INTERVENTIONAL
2017-05-23
2019-11-09
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Catheter Ablation for Atrial Fibrillation in Non-Fluoroscopic Lab
NCT06719921
Procedural Mitral Isthmus Block Durability After Pulsed-Field Ablation in Patients with Non-Paroxysmal Atrial Fibrillation
NCT06803238
Epicardial Mini-Maze Versus Catheter Ablation for the Management of Persistent Atrial Fibrillation
NCT03446222
Prospective Elimination Of Distal Coronary Sinus-Left Atrial Connections for Atrial Fibrillation Ablation Trial
NCT03646643
Minimally Invasive Surgical Treatment Versus Medical Management for Stroke Patients With Atrial Fibrillation
NCT01442181
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Usually, the procedure is simple and straightforward and complete heart block can be achieved without any difficulty. However, this "simple" procedure can sometimes prove to be a most difficult case. The most common reason for failure to achieve complete heart block is the inability to localize the compact AV node using the His signal with standard intracardiac electrograms. As these patients come to the laboratory in AF, the His signal may be obscured by AF waves. In some patients with a deeper intramyocardial location of the His bundle and compact AV node it becomes necessary to produce deeper ablation lesions using an irrigated catheter to achieve block.
In patients with AF, the target of ablation for the "ablate and pace" approach is the compact AV node, located at the apex of the triangle of Koch. Ideally, ablation is performed at the most proximal penetrating part of the His bundle in order to maintain a proximal automatic junctional rhythm and avoid pacemaker dependence.
Para Hisian pacing is most commonly used to reveal the presence of a septal accessory pathway.
The His bundle is a deep insulated structure and it is difficult to capture it at usual energy outputs. Using a high- output pacing (usually 20 mA at 2 msec) it is possible to directly capture the deeply situated His bundle, which is confirmed by a narrower QRS complex on the paced electrograms. Thus, high-output pacing can be utilized to map the His bundle area in difficult situations.
By applying this electrophysiologic principle of differential tissue capture to help identify the location of the compact AV node, which is in close proximity to the His bundle. Ventricular pacing was performed initially at high output to capture both the basal right ventricular myocardium and the His bundle and the output was gradually lowered to lose His bundle capture. The QRS duration is relatively narrow with high output pacing and increases when the pacing output is lowered, representing ventricular myocardial capture alone. Finally, loss of ventricular capture is seen with further reduction of pacing output. This maneuver has been shown to aid in determining the proximity of the ablation catheter to compact AV node as was validated by successful ablation at this site. Parahisian pacing in conjunction with av nodal ablation has recently been described in the literature.
A novel catheter with three mini electrodes within the ablation tip (IntellaTip MiFi, Boston Scientific, Boston, MA) may enhance the available data for such a signal dependent technique. In this catheter, bipolar signals can be recorded between the three 0.8-mm-wide electrodes that are arranged radially 1.3 mm from the end of the catheter alongside the standard distal and proximal bipolar recordings. Animal studies have already demonstrated that the mini electrodes in this novel catheter are more accurate in identifying conducting gaps in linear ablations than conventional electrode recordings.
Study Aims:
The aim of our study is to investigate the comparative efficacy of high fidelity multi electrode ablation catheters vs the standard bipolar configuration in success of AV nodal ablation This study will provide insights on the use of new technology where application may increase efficacy, promote patient and physician safety and decrease costs.
Primary and secondary objectives Primary endpoints
1. Acute success of ablation identified by a junctional rhythm or complete heart block
2. Time from application of radiofrequency energy to acute success
Secondary endpoints include
1. Procedure time
2. Radiation time
3. Frequency of ablation application
4. Duration of ablation application
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
RANDOMIZED
PARALLEL
TREATMENT
SINGLE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Bipolar Ablation Catheter
Subjects will be randomized by random computer programming to receive standard ablation catheter for their procedure.
Standard Ablation Catheter
Standard of care for patients with certain cardiac arrhythmias.
MIFI Ablation Catheter
Subjects will be randomized by random computer programming to receive an ablation with MIFI technology. MIFI Catheter contains tightly spaced multielectrode pattern
MIFI Catheter
Multielectrode Catheter: standard ablation catheter that has the ability to record low and high frequency signals with high fidelity
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
MIFI Catheter
Multielectrode Catheter: standard ablation catheter that has the ability to record low and high frequency signals with high fidelity
Standard Ablation Catheter
Standard of care for patients with certain cardiac arrhythmias.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
2. Patients must meet American College of Cardiology and Heart Rhythm Society "ACC/HRS" guidelines for atrioventricular nodal ablation procedure
3. Patients must be available for at least 1 month post procedure
4. Patients must be greater than or equal to 18 years old.
Exclusion Criteria
18 Years
95 Years
ALL
Yes
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
University of Florida
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
John N Catanzaro, MD
Role: PRINCIPAL_INVESTIGATOR
University of Florida
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
University of Florida
Jacksonville, Florida, United States
Countries
Review the countries where the study has at least one active or historical site.
Provided Documents
Download supplemental materials such as informed consent forms, study protocols, or participant manuals.
Document Type: Study Protocol and Statistical Analysis Plan
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
ir-iis02
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.