Non-Invasive Diagnosis of Pulmonary Vascular Disease Using Inhaled 129Xe Magnetic Resonance Imaging
NCT ID: NCT03078192
Last Updated: 2022-02-22
Study Results
Outcome measurements, participant flow, baseline characteristics, and adverse events have been published for this study.
View full resultsBasic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
PHASE2
62 participants
INTERVENTIONAL
2017-05-03
2020-10-22
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Assessing Response to Inhaled Prostacyclin With Hyperpolarized Xe MRI
NCT03367312
129Xe MRI Cardiopulmonary
NCT06038630
Xenon MRI Pulm Hypertension
NCT04991454
Longitudinal MR Imaging of Pulmonary Function in Patients Receiving Thoracic Radiation Treatment
NCT02478255
129 Xenon MRI as a Biomarker for Diagnosis and Response to Therapy in Pulmonary Arterial Hypertension (PAH)
NCT06104228
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Aim 1. Perform 129Xe MRI scans in cohorts of patients with PVD, isolated left sided heart failure and isolated lung disease:
1.1 Deploy and optimize 129Xe gas exchange MR spectroscopy and imaging, 129Xe ventilation MRI, structural 1H UTE MRI, and breath-hold 1H perfusion MRI.
1.2 Conduct comprehensive 1H-129Xe MRI in 10 patients with pure pulmonary arterial hypertension (PAH) 1.3 Conduct comprehensive MRI in 10 patients with pure left heart failure 1.4 Conduct comprehensive MRI in 10 patients with pure lung disease but no pulmonary hypertension 1.5 Conduct comprehensive MRI in 5 patients with Chronic thromboembolic pulmonary hypertension (CTEPH) pre and post PTE surgery.
Aim 2. Develop diagnostic criteria for optimizing the sensitivity and specificity of 129Xe MRI for the diagnosis of PVD:
2.1 Develop quantification/scoring methods based on PAH, left heart disease, and lung disease MRI 2.2 Develop reader training materials and train 3 expert readers 2.3 Begin prospective recruitment of 92 patients being evaluated for PAH for MRI scans. These patients may be asked to return for a second scan in the study, at a time no earlier than 48hr after their last xenon dose.
Aim 3. Perform a larger, single-blind study testing the diagnostic accuracy of 129Xe MRI for diagnosis of PVD:
3.1 Trained readers will evaluate 129Xe MRI, while blinded to the subject's disease state and will determine the presence and severity of PVD 3.2 Diagnostic accuracy of 129Xe MRI will be compared to the gold standard of hemodynamic and clinical criteria of PAH
1. For this PFTs are not necessary, so they are ancillary
2. However, they are a standard way to characterize patients for publications, etc, so we would like to get them if we can. Getting them from the medical record is perfectly adequate for this pur-pose.
i. If PFTs are not available from the medical record, they are not so critical as to pre-vent us from enrolling the subject. In publications we will simply acknowledge the realities of COVID for this missing data.
This will be an single-blinded, open-label study enrolling volunteers and patients with pure PAH (10 subjects), pure left heart disease (10 subjects) and pure lung disease (10 subjects) \[Aim 1\] followed by a larger cohort of 92 subjects being evaluated for PAH \[Aim 2\]. The investigators plan to consent to 127 subjects.
The sample size calculation is based on testing whether the proposed diagnostic test based on Xe MRI has accuracy comparable to imaging diagnostic procedures in clinical practice, such as mammography. To this end, the investigator proposes to test the hypotheses H0: AUC = 0.72 vs. H1: AUC \> 0.85, where area under the curve (AUC) is a summary measure of diagnostic accuracy obtained as the the area under the receiver operating characteristic (ROC) curve which displays the tradeoff between sensitivity and specificity for our proposed Xe MRI based diagnostic test. Here AUC = 0.72 represents a moderately accurate test while AUC = 0.85 represents accuracy comparable to clinical mammography. Based on a one sided, one sample test with variances approximated using the binormal model, the investigator estimates a minimum sample size of 46 normals and 46 with disease will be required to test the above hypotheses at a significance level of 5% with 80% power.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NON_RANDOMIZED
SEQUENTIAL
DIAGNOSTIC
SINGLE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Training Set - PVD, Isolated Left Heart Failure, Isolated Lung Disease
Patients with Pulmonary Vascular Disease (10 subjects), isolated left sided heart failure (10 subjects), and isolated lung disease(10 subjects) will undergo Xe MRI scans with GE-141, Hyperpolarized 129Xenon gas to develop diagnostic criteria for optimizing the sensitivity and specificity of XeMRI for the diagnosis of PVD
GE-141, Hyperpolarized 129Xenon gas
XeMRI scans will provide 3D images of ventilation and gas exchange. Subjects will inhale HP 129Xe from the dose delivery bags. Then the subject will be moved into the scanner and they will undergo basic 1H localizer and anatomical scans. Once localization is complete, subjects will under-go several MRI scans after inhalation of HPXe
MRI
Perform MRI scans with administration of GE-141, Hyperpolarized 129Xenon
Test Set - Pulmonary Vascular Disease
92 subjects being evaluated for undergoing right heart catheterization for evaluation of PAH or other cardiac or pulmonary disease for testing of diagnostic accuracy of XeMRI for diagnosis of PVD
GE-141, Hyperpolarized 129Xenon gas
XeMRI scans will provide 3D images of ventilation and gas exchange. Subjects will inhale HP 129Xe from the dose delivery bags. Then the subject will be moved into the scanner and they will undergo basic 1H localizer and anatomical scans. Once localization is complete, subjects will under-go several MRI scans after inhalation of HPXe
MRI
Perform MRI scans with administration of GE-141, Hyperpolarized 129Xenon
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
GE-141, Hyperpolarized 129Xenon gas
XeMRI scans will provide 3D images of ventilation and gas exchange. Subjects will inhale HP 129Xe from the dose delivery bags. Then the subject will be moved into the scanner and they will undergo basic 1H localizer and anatomical scans. Once localization is complete, subjects will under-go several MRI scans after inhalation of HPXe
MRI
Perform MRI scans with administration of GE-141, Hyperpolarized 129Xenon
Other Intervention Names
Discover alternative or legacy names that may be used to describe the listed interventions across different sources.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
2. Willing and able to give informed consent and adhere to visit/protocol schedules. (Consent must be given before any study procedures are performed)
3. Women of childbearing potential must have a negative urine pregnancy test. This will be confirmed before participation in this investigational protocol.
4. Either has a diagnosis of PAH, isolated left heart disease or lung disease (chronic obstructive pulmonary disease or interstitial lung disease) or CTEPH using established clinical criteria.
5. Patients undergoing right heart catheterization for evaluation of PAH or other cardiac or pulmonary disease for MRI scans
Exclusion Criteria
* Conditions that will prohibit MRI scanning (metal in eye, claustrophobia, inability to lie supine)
18 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
National Heart, Lung, and Blood Institute (NHLBI)
NIH
Bastiaan Driehuys
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Bastiaan Driehuys
Professor, Duke University Medical Center
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Duke University Medical Center
Durham, North Carolina, United States
Countries
Review the countries where the study has at least one active or historical site.
Provided Documents
Download supplemental materials such as informed consent forms, study protocols, or participant manuals.
Document Type: Study Protocol and Statistical Analysis Plan
Document Type: Informed Consent Form
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
HHSN268201700001C
Identifier Type: OTHER
Identifier Source: secondary_id
Pro00079617
Identifier Type: -
Identifier Source: org_study_id