Non-Invasive Diagnosis of Pulmonary Vascular Disease Using Inhaled 129Xe Magnetic Resonance Imaging

NCT ID: NCT03078192

Last Updated: 2022-02-22

Study Results

Results available

Outcome measurements, participant flow, baseline characteristics, and adverse events have been published for this study.

View full results

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Clinical Phase

PHASE2

Total Enrollment

62 participants

Study Classification

INTERVENTIONAL

Study Start Date

2017-05-03

Study Completion Date

2020-10-22

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

This study seeks to deploy several forms of 129Xe MRI contrast as well as emerging conventional proton MRI technqiues for imaging lung structure and perfusion. Specifically, the 129Xe MRI scans will provide 3D images of ventilation and gas exchange, and spectroscopic indices will be evaluated to test gas exchange dynamics with high temporal resolution. The conventional 1H MRI scans will include a free-breathing ultra-short echo time (UTE) scan that provides images similar to that of a CT scan. In addition, to characterize perfusion and vascular dimensions directly, patients will undergo a gadolinium-enhanced perfusion scan.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

This study seeks to deploy several forms of 129Xe MRI contrast as well as emerging conventional proton MRI technqiues for imaging lung structure and perfusion. Specifically, the 129Xe MRI scans will provide 3D images of ventilation and gas exchange, and spectroscopic indices will be evaluated to test gas exchange dynamics with high temporal resolution. The conventional 1H MRI scans will include a free-breathing ultra-short echo time (UTE) scan that provides images similar to that of a CT scan. In addition, to characterize perfusion and vascular dimensions directly, patients will undergo a gadolinium-enhanced perfusion scan. The overall aims of the study are as follows:

Aim 1. Perform 129Xe MRI scans in cohorts of patients with PVD, isolated left sided heart failure and isolated lung disease:

1.1 Deploy and optimize 129Xe gas exchange MR spectroscopy and imaging, 129Xe ventilation MRI, structural 1H UTE MRI, and breath-hold 1H perfusion MRI.

1.2 Conduct comprehensive 1H-129Xe MRI in 10 patients with pure pulmonary arterial hypertension (PAH) 1.3 Conduct comprehensive MRI in 10 patients with pure left heart failure 1.4 Conduct comprehensive MRI in 10 patients with pure lung disease but no pulmonary hypertension 1.5 Conduct comprehensive MRI in 5 patients with Chronic thromboembolic pulmonary hypertension (CTEPH) pre and post PTE surgery.

Aim 2. Develop diagnostic criteria for optimizing the sensitivity and specificity of 129Xe MRI for the diagnosis of PVD:

2.1 Develop quantification/scoring methods based on PAH, left heart disease, and lung disease MRI 2.2 Develop reader training materials and train 3 expert readers 2.3 Begin prospective recruitment of 92 patients being evaluated for PAH for MRI scans. These patients may be asked to return for a second scan in the study, at a time no earlier than 48hr after their last xenon dose.

Aim 3. Perform a larger, single-blind study testing the diagnostic accuracy of 129Xe MRI for diagnosis of PVD:

3.1 Trained readers will evaluate 129Xe MRI, while blinded to the subject's disease state and will determine the presence and severity of PVD 3.2 Diagnostic accuracy of 129Xe MRI will be compared to the gold standard of hemodynamic and clinical criteria of PAH

1. For this PFTs are not necessary, so they are ancillary
2. However, they are a standard way to characterize patients for publications, etc, so we would like to get them if we can. Getting them from the medical record is perfectly adequate for this pur-pose.

i. If PFTs are not available from the medical record, they are not so critical as to pre-vent us from enrolling the subject. In publications we will simply acknowledge the realities of COVID for this missing data.

This will be an single-blinded, open-label study enrolling volunteers and patients with pure PAH (10 subjects), pure left heart disease (10 subjects) and pure lung disease (10 subjects) \[Aim 1\] followed by a larger cohort of 92 subjects being evaluated for PAH \[Aim 2\]. The investigators plan to consent to 127 subjects.

The sample size calculation is based on testing whether the proposed diagnostic test based on Xe MRI has accuracy comparable to imaging diagnostic procedures in clinical practice, such as mammography. To this end, the investigator proposes to test the hypotheses H0: AUC = 0.72 vs. H1: AUC \> 0.85, where area under the curve (AUC) is a summary measure of diagnostic accuracy obtained as the the area under the receiver operating characteristic (ROC) curve which displays the tradeoff between sensitivity and specificity for our proposed Xe MRI based diagnostic test. Here AUC = 0.72 represents a moderately accurate test while AUC = 0.85 represents accuracy comparable to clinical mammography. Based on a one sided, one sample test with variances approximated using the binormal model, the investigator estimates a minimum sample size of 46 normals and 46 with disease will be required to test the above hypotheses at a significance level of 5% with 80% power.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Pulmonary Vascular Disease

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

NON_RANDOMIZED

Intervention Model

SEQUENTIAL

This will be a single blinded open label study enrolling volunteers and patients with pure PAH (10 subjects), pure left heart disease (10 subjects) and pure lung disease (10 subjects), 5 CTEPH in Aim 1; followed by a larger cohort of 92 subjects with PAH or other cardiac or pulmonary disease for MRI scans
Primary Study Purpose

DIAGNOSTIC

Blinding Strategy

SINGLE

Outcome Assessors
The outcomes assessor, the radiologist who is reading the imaging will be blinded to treatment.

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Training Set - PVD, Isolated Left Heart Failure, Isolated Lung Disease

Patients with Pulmonary Vascular Disease (10 subjects), isolated left sided heart failure (10 subjects), and isolated lung disease(10 subjects) will undergo Xe MRI scans with GE-141, Hyperpolarized 129Xenon gas to develop diagnostic criteria for optimizing the sensitivity and specificity of XeMRI for the diagnosis of PVD

Group Type EXPERIMENTAL

GE-141, Hyperpolarized 129Xenon gas

Intervention Type DRUG

XeMRI scans will provide 3D images of ventilation and gas exchange. Subjects will inhale HP 129Xe from the dose delivery bags. Then the subject will be moved into the scanner and they will undergo basic 1H localizer and anatomical scans. Once localization is complete, subjects will under-go several MRI scans after inhalation of HPXe

MRI

Intervention Type DEVICE

Perform MRI scans with administration of GE-141, Hyperpolarized 129Xenon

Test Set - Pulmonary Vascular Disease

92 subjects being evaluated for undergoing right heart catheterization for evaluation of PAH or other cardiac or pulmonary disease for testing of diagnostic accuracy of XeMRI for diagnosis of PVD

Group Type EXPERIMENTAL

GE-141, Hyperpolarized 129Xenon gas

Intervention Type DRUG

XeMRI scans will provide 3D images of ventilation and gas exchange. Subjects will inhale HP 129Xe from the dose delivery bags. Then the subject will be moved into the scanner and they will undergo basic 1H localizer and anatomical scans. Once localization is complete, subjects will under-go several MRI scans after inhalation of HPXe

MRI

Intervention Type DEVICE

Perform MRI scans with administration of GE-141, Hyperpolarized 129Xenon

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

GE-141, Hyperpolarized 129Xenon gas

XeMRI scans will provide 3D images of ventilation and gas exchange. Subjects will inhale HP 129Xe from the dose delivery bags. Then the subject will be moved into the scanner and they will undergo basic 1H localizer and anatomical scans. Once localization is complete, subjects will under-go several MRI scans after inhalation of HPXe

Intervention Type DRUG

MRI

Perform MRI scans with administration of GE-141, Hyperpolarized 129Xenon

Intervention Type DEVICE

Other Intervention Names

Discover alternative or legacy names that may be used to describe the listed interventions across different sources.

Xe MRI

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

1. Outpatients of either gender, age \> 18
2. Willing and able to give informed consent and adhere to visit/protocol schedules. (Consent must be given before any study procedures are performed)
3. Women of childbearing potential must have a negative urine pregnancy test. This will be confirmed before participation in this investigational protocol.
4. Either has a diagnosis of PAH, isolated left heart disease or lung disease (chronic obstructive pulmonary disease or interstitial lung disease) or CTEPH using established clinical criteria.
5. Patients undergoing right heart catheterization for evaluation of PAH or other cardiac or pulmonary disease for MRI scans

Exclusion Criteria

* Medical or psychological conditions which, in the opinion of the investigator, might create undue risk to the subject or interfere with the subject's ability to comply with the protocol requirements
* Conditions that will prohibit MRI scanning (metal in eye, claustrophobia, inability to lie supine)
Minimum Eligible Age

18 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

National Heart, Lung, and Blood Institute (NHLBI)

NIH

Sponsor Role collaborator

Bastiaan Driehuys

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Bastiaan Driehuys

Professor, Duke University Medical Center

Responsibility Role SPONSOR_INVESTIGATOR

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Duke University Medical Center

Durham, North Carolina, United States

Site Status

Countries

Review the countries where the study has at least one active or historical site.

United States

Provided Documents

Download supplemental materials such as informed consent forms, study protocols, or participant manuals.

Document Type: Study Protocol and Statistical Analysis Plan

View Document

Document Type: Informed Consent Form

View Document

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

HHSN268201700001C

Identifier Type: OTHER

Identifier Source: secondary_id

Pro00079617

Identifier Type: -

Identifier Source: org_study_id

More Related Trials