Clinical Study on Mesenchymal Stem Cells Used in the Reconstruction Surgery of the Supraspinatus Muscle Lesions
NCT ID: NCT03068988
Last Updated: 2017-09-07
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
UNKNOWN
PHASE1
50 participants
INTERVENTIONAL
2012-01-01
2021-12-31
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Mesenchymal Stem Cells and Amniotic Membrane Composite for Supraspinatus Tendon Repair Augmentation
NCT04670302
Clinical Study on the Safety and Efficacy of Tendon Stem Progenitor Cells Therapy for Rotator Cuff Tears
NCT07320378
Mesenchymal Stem Cell Augmentation in Patients Undergoing Arthroscopic Rotator Cuff Repair
NCT02484950
Mesenchymal Stem Cells in Rotator Cuff Repair
NCT03362424
Utilization of AMSC to Enhance Rotator Cuff Repair - Safety and Efficacy
NCT03838666
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Before the surgical treatment, patients completed a questionnaire with VAS score, ASES score ( American Shoulder and Elbow Surgeons Standardized Shoulder Assessment Form ) and the Constant score. Further clinical control with completing these questionnaires is 6 months after surgery, 1 year after surgical treatment, 2, 5 and ten years postoperatively. Two years after the surgery MRI examination of the shoulder joint is performed. All of the outpatient clinical evaluations during the study were performed by the orthopaedic surgeon blinded to the both groups of patients.
The actual therapy was as follows: open surgery was preceded by a standard diagnostic arthroscopy, which was performed from the posterior portal for optics and anterior portal for arthroscopic instruments. The tendons of the rotator cuff were assessed from both sides - intraarticular and subacromial. To evaluate cuff tendon injury perioperatively and to measure the rupture width, a special arthroscopic hook calibrated in 1 mm was used. To evaluate the shape of the rupture, the classification of Ellman - Gartsman was used. Surgical treatment of injured tendons of the rotator cuff was performed in the beach chair position of the patient, by the deltoid muscle split approach. After evaluation of the extent and location of the cuff tendon lesion the aspiration of 10 ml of bone marrow blood was done ( from the humeral head through the same surgical approach ) into a 20 mL syringe prefilled with 0.5 ml of heparin with the Yamshidi needle. Aspiration of the bone marrow was performed by surgeon. From one bone puncture was aspirated maximally 3 ml of marrow blood. Centrifugation of the aspirate in 10 ml test-tube Monovette filled with citrate followed. Selected centrifugation regime consisted of gradient 15 minute centrifugation at 200 g RCF ( relative centrifugal force ). After such a centrifugation the tube contents is divided into three parts. The upper layer consists of the platelet-rich plasma (PRP), the middle layer of the buffy coat with the dominant proportion of leukocytes, and the lower layer is formed by sedimented erythrocytes. Using a sterile laboratory pipette, a collection of the buffy coat was performed. MSCs represented 0.01 to 0.02 % of all nuclear elements of the buffy coat, that is about 10 x 106 / l. The MSCs concentrate ( similar to synovial fluid in consistency and colour ) was impregnated into the collagen patch Hypro-Sorb F ( Otrokovice, Czech Republic ) of dimensions 1x2 cm. The collagen patch as a carrier of the MSCs concentrate was used to ensure its retention in desired place. This material was then inserted between the tendon and bone, into the place of re-fixing of the rotator cuff tendons ( footprint ) before tightening the threads of the anchors. Fixation of the tendon to the bone was made by a double row method with use of absorbable fixation anchors BioComposite Corkscrew ( Arthrex, Munich, Germany ). In all such treated cases the tendon was fixed in place of original attachment without any stress and without the need of abduction of the arm above 60 degrees. All patients underwent Neer acromioplasty for an increase of the subacromial space. This procedure was followed by the standard surgical wound closure in all anatomical layers, sterile dressing of the wound and by applying of the abduction orthosis. All patients were operated by the same orthopaedic surgeon with the same surgical technique. Open surgery instead of arthroscopy was chosen because of the safer fixation of the MSCs carrier under the re-inserted tendon and to reduce the risk of washout of the MSCs concentrate from the carrier during the arthroscopy.
Surgical treatment of patients in Group II was identical as in Group I, except the aspiration of bone marrow from the humeral head and subsequent application of the scaffold saturated with MSCs into the tendon / bone interface.
Abduction fixation lasted for 4 weeks. Passive motion over the horizontal line under the guidance of a physiotherapeutist was initiated the first postoperative day. After removing the fixation, an active rehabilitation began, that is a full range of motion exercises done actively 6 weeks after surgery. Full load was allowed 12 weeks after the surgery.
Outpatient follow-up took place according to the schedule mentioned above. To check the integrity of the tendon at the point of insertion into the greater tuberosity of the humerus, MRI of the shoulder joint was performed 2 years postoperatively. Both, preoperative and postoperative MRI examinations were performed with a 1.5T high-field scanner, in sagittal, coronal, and axial planes, in T1- and T2-weighted fat-saturated sequences ( MRI arthrography using gadollinium as a contrast medium ). All of MRI results were evaluated by an experienced radiologist specialized in musculoskeletal pathologies. He evaluated tendon integrity, presence and localisation of complete retear, tendon and muscle borders, and presence of abnormal artifacts.
The primary hypothesis of this study is that the use of mesenchymal stem cells in the supraspinatus tendon reconstruction surgery will have a positive effect in the assessment of both subjective and objective scoring systems, and also in terms of reducing the number of tendon reruptures compared to the patients population in which mesenchymal stem cells were not used. All data were statistically analyzed with STATISTICA 9.0 programme. To compare the results of the of the VAS score, the Constant score, and the ASES score preoperatively and one year after the surgery Student´s t- test was used, to compare the incidence of reruptures between both groups of patients 2 years postoperatively Chi-square test was used. The significance level was determined at p \<0.05. Patients were randomly assigned to one of the treatment possibilities with use of the Random Number Generator Software 7.0 by the method 1:1
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
RANDOMIZED
PARALLEL
TREATMENT
TRIPLE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
mesenchymal stem cells
mesenchymal stem cells concentrate into the supraspinatus footprint during the surgery
mesenchymal stem cells
mesenchymal stem cells concentrate into the supraspinatus footprint during the surgery
without mesenchymal stem cells
rotator cuff surgery without mesenchymal stem cells
without mesenchymal stem cells
rotator cuff surgery without mesenchymal stem cells
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
mesenchymal stem cells
mesenchymal stem cells concentrate into the supraspinatus footprint during the surgery
without mesenchymal stem cells
rotator cuff surgery without mesenchymal stem cells
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* chronic supraspinatus tendon tear greater than 50% of its width
* no history of trauma to the examined shoulder girdle
* confirmation by the clinical examination and preoperative imaging examination ( MRI arthrography )
* signed informed consent
* minimum preoperative haemoglobin concentration in men 13.8 g / dl, in women 12.1 g / dl
Exclusion Criteria
* cuff tear arthropathy grade 3-5 according to Hamada
* fatty degeneration of the cuff muscle ( Goutallier 3 and 4 )
* atrophy of the supraspinatus muscle according to the Thomazeau classification grade II and III
* retraction of the supraspinatus muscle tendon Patte III
* pregnancy
* active infection at the surgical site or elsewhere in the body
* osteomyelitis
* sepsis
* history of diabetes
* steroids use
* chemotherapy
* use of NSAIDs
* radiation
* hepatitis
* HIV
* hemato / oncological diseases
* alcohol abuse
* drug abuse
* cigarettes
* medical condition that affects the growth of bone or connective tissue (osteomalacia or other metabolic bone disease)
* vascular insufficiency
* operated extremity muscle atrophy
* neuromuscular disease
18 Years
60 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Hospital Znojmo
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
MUDr. Petr Šmíd
Prinicpal investigator, Doctor
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Petr Šmíd, Dr.
Role: PRINCIPAL_INVESTIGATOR
General Hospital Znojmo, Czech Republic
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Petr Šmíd
Znojmo, Czech Republic, Czechia
Countries
Review the countries where the study has at least one active or historical site.
References
Explore related publications, articles, or registry entries linked to this study.
Goutallier D, Postel JM, Bernageau J, Lavau L, Voisin MC. Fatty muscle degeneration in cuff ruptures. Pre- and postoperative evaluation by CT scan. Clin Orthop Relat Res. 1994 Jul;(304):78-83.
Thomazeau H, Boukobza E, Morcet N, Chaperon J, Langlais F. Prediction of rotator cuff repair results by magnetic resonance imaging. Clin Orthop Relat Res. 1997 Nov;(344):275-83.
Patte D. Classification of rotator cuff lesions. Clin Orthop Relat Res. 1990 May;(254):81-6.
Richards RR, An KN, Bigliani LU, Friedman RJ, Gartsman GM, Gristina AG, Iannotti JP, Mow VC, Sidles JA, Zuckerman JD. A standardized method for the assessment of shoulder function. J Shoulder Elbow Surg. 1994 Nov;3(6):347-52. doi: 10.1016/S1058-2746(09)80019-0. Epub 2009 Feb 13.
Constant CR, Murley AH. A clinical method of functional assessment of the shoulder. Clin Orthop Relat Res. 1987 Jan;(214):160-4.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
2016/05/25/09
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.