Day and Night Closed-loop in Young People With Type 1 Diabetes

NCT ID: NCT02925299

Last Updated: 2021-02-02

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Clinical Phase

NA

Total Enrollment

131 participants

Study Classification

INTERVENTIONAL

Study Start Date

2017-05-12

Study Completion Date

2020-08-27

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

The main study objective is to determine whether 24/7 automated closed-loop glucose control combined with low glucose feature will improve glucose control as measured by HbA1c.

This is an open-label, multi-centre, multi-national, single-period, randomised, parallel group design study, involving a 6 month period of home study during which day and night glucose levels will be controlled either by a closed-loop system combined with low glucose feature (intervention group) or by insulin pump therapy alone (control group).

It is expected that a total of up to 150 subjects (aiming for 130 randomised subjects) with type 1 diabetes will be recruited through paediatric outpatient diabetes clinics of the investigation centres. Participants will all be on subcutaneous insulin pump therapy.

Subjects in the intervention group will have proven competencies both in the use of the study insulin pump and the study continuous glucose monitoring (CGM) device, and will receive appropriate training in the safe use of closed-loop insulin delivery system and low glucose feature. All subjects will have regular contact with the study team during the home study phase including 24/7 telephone support. The primary outcome is between group differences in HbA1c levels at 6 months post study arm initiation. Secondary outcomes are the time spent in the glucose target (3.9 to 10.0mmol/l; 70 to 180mg/dl), time spent with glucose levels above and below target, as recorded by CGM, and other CGM-based metrics. Safety evaluation comprises assessment of the frequency of severe hypoglycaemic episodes and diabetic ketoacidosis (DKA).

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

* Purpose of the study: To determine whether 24/7 automated closed-loop glucose control will improve glucose control as measured by glycated haemoglobin and reduce the burden of hypoglycaemia compared to insulin pump therapy alone.
* Study Objectives:

1. EFFICACY: The objective is to assess efficacy of day and night automated closed-loop glucose control in improving glucose control as measured by glycated haemoglobin, as compared to insulin pump therapy alone.
2. SAFETY: The objective is to evaluate the safety of day and night automated closed-loop glucose control, in terms of episodes of severe hypoglycaemia and other adverse events.
3. UTILITY: The objective is to determine the frequency and duration of the use of the automated closed-loop system.
4. HUMAN FACTORS: The objective is to assess cognitive, emotional, and behavioural characteristics of participating subjects and family members and their response to the closed-loop system and clinical trial using validated surveys and focus groups.
5. HEALTH ECONOMICS: The objective is to perform a cost utility analysis to inform reimbursement decision-making.
* Study Design: An open-label, multi-centre, randomised, single-period parallel study, contrasting day-and-night automated closed-loop glucose control with insulin pump therapy alone.
* Population: 130 participants randomised (equal proportion of those aged 6 to 12 years and 13 to 18 years, a minimum quota of 25% participants with baseline HbA1c \>8.5%)
* Maximum duration of study for a subject: 8 months
* Recruitment: The subjects will be recruited through the pediatric outpatient clinics at each center.
* Consent: Written consent / assent will be obtained from participants and/or guardians according to REC / IRB requirements
* Screening Assessments: Eligible participants will undergo a screening evaluation where blood samples for full blood count, liver, thyroid function and anti-transglutaminase antibodies (with IgA levels if not done within previous 12 months) will be taken. Non-hypoglycaemia C-peptide, glucose and HbA1c will also be measured, and a urine pregnancy test in females of child-bearing potential will be performed.

Surveys investigating participants' quality of life, psychosocial and cognitive functioning, and response to their current treatment will be distributed.

Participants will be fitted with a blinded continuous glucose monitoring (CGM) device to assess baseline glycaemic control. Instructions on how to safely use, remove and send back the device will be provided.

* Study Training: Training sessions on the use of study CGM, insulin pump (and closed loop system for those randomized to be intervention group) will be provided by the research team. Training session on the use of real-time CGM and on how to interpret real-time and retrospective stored data will be provided to all subjects / carers using written material.
* Run-In Period: During a 1-2 week run-in period, subjects will continue using their own insulin pump. Data obtained from blinded CGM and pump downloads may be utilised for therapy adjustment.
* Competency Assessment: Competency on the use of study insulin pump and study CGM will be evaluated using a competency assessment tool developed by the research team. Further training may be delivered as required.
* Randomization: Eligible subjects will be randomised using randomisation software to the use of real-time CGM and low glucose feature combined with day and night closed-loop or to conventional insulin pump therapy alone.

A blood sample will be taken for the measurement of HbA1c and a urine pregnancy test in females of child-bearing potential. A blood sample for centralised analysis of HbA1c will be taken if screening and randomisation are \>28 days apart.

1. Automated day and night closed-loop insulin delivery (intervention arm) combined with low glucose feature (interventional arm) - Participants in the closed-loop group will receive additional training sessions following randomisation covering the use of the study insulin pump and real-time CGM, prior to starting closed-loop insulin delivery.

Once confident with the use of the study pump and CGM system, participants will receive training required for safe and effective use of the closed-loop system approximately 2-4 weeks after randomisation. During this 2-4 hour session participants will operate the system under the supervision of the clinical team. Competency on the use of closed-loop system will be evaluated.

Thereafter, participants are expected to use closed-loop for 6 months without direct real-time remote monitoring.
2. Insulin pump therapy (control arm) - Refresher training on key aspects of insulin pump therapy will be provided.

Subjects will continue using their own insulin pump for 6 months.

* 3-month and 6 month assessments:

1. A blood sample will be taken for measurement of HbA1c and a urine pregnancy test in females of child-bearing potential.
2. Validated surveys evaluating the impact of the devices employed on quality of life, psychosocial and cognitive functioning, diabetes management and treatment satisfaction will be completed.
3. Participants of both study arms will be fitted with blinded CGM systems at the end of each follow up visit. The sensors will be worn at home for up to 14 days and will be sent back to the research team.

6 months only: Subjects/guardians will be invited to join follow-up focus groups to gather feedback and reactions to their current treatment (closed-loop or insulin pump), the clinical trial, and quality of life changes.
* Study Contacts: In between study visits, participants will be contacted by the study team (email or phone) once monthly in order to record any adverse events, device deficiencies, and changes in insulin settings, other medical conditions and/or medication.

In case of any technical device or problems related to diabetes management such as hypo- or hyperglycaemia, subjects will be able to contact a 24-hour telephone helpline to the local research team at any time. The local research team will have access to central 24 hour advice on technical issues.

--Procedures for safety monitoring during trial: Standard operating procedures for monitoring and reporting of all adverse events will be in place, including serious adverse events (SAE), serious adverse device effects (SADE) and specific adverse events (AE) such as severe hypoglycaemia.

Subjects will be asked to test and record blood ketones if their finger prick glucose is \> 16.7mmol/l (300mg/dl) upon awakening, \>300 for more than 1 hour, or \>22.2mmo/l (400mg/dL) at any time as part of the safety assessment for DKA.

A data safety and monitoring board (DSMB) will be informed of all serious adverse events and any unanticipated serious adverse device effects that occur during the study and will review compiled adverse event data at periodic intervals.

--Criteria for withdrawal of patients on safety grounds: A subject, parent, or guardian may terminate participation in the study at any time without necessarily giving a reason and without any personal disadvantage. An investigator can stop the closed-loop intervention after consideration of the benefit/risk ratio. Possible reasons are:

1. Serious adverse events
2. Significant protocol violation or non-compliance
3. Failure to satisfy competency assessment
4. Decision by the investigator, or the sponsor, that termination is in the subject's best medical interest
5. Pregnancy, planned pregnancy, or breast feeding
6. Allergic reaction to insulin

Efforts will be made to retain subjects in follow up for the final primary outcome assessment even if the intervention is discontinued, unless the investigator believes that it will be harmful for the subject to continue in the trial.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Diabetes Mellitus Diabetes Mellitus, Type 1 Glucose Metabolism Disorders Endocrine System Diseases Autoimmune Diseases

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

RANDOMIZED

Intervention Model

PARALLEL

Primary Study Purpose

TREATMENT

Blinding Strategy

NONE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

24/7 closed loop insulin delivery

The study system includes (1) a CGM that measures glucose levels, (2) a computer program on a smartphone that determines how much insulin is needed, and (3) an insulin pump that delivers the insulin. The name of this closed-loop system used in the US is FlorenceM (Medtronic 640G pump and Guardian3 sensor). The name of this closed-loop system in the UK is FlorenceX (DANA pump and Dexcom sensor). Half of the individuals taking part in the study will use the closed-loop study system for 6 months.

Group Type EXPERIMENTAL

FlorenceM (US) and FlorenceX (UK)

Intervention Type DEVICE

The automated closed loop system (FlorenceM in US) will consist of:

Next generation sensor augmented Medtronic insulin pump 640G (Medtronic Minimed, CA, USA) incorporating the Medtronic Guardian3 CGM and glucose suspend feature.

The automated closed loop system (FlorenceX in UK) will consist of:

The DANA Diabecare R insulin pump (Sooil Development, Korea) incorporating the Dexcom G6 CGM.

An Android smartphone containing the Cambridge model predictive algorithm and communicating wirelessly with the insulin pump using a proprietary translator device.

Insulin pump therapy

Half of the Subjects will continue using their own insulin pump for 6 months.

Group Type ACTIVE_COMPARATOR

Insulin pump therapy

Intervention Type DEVICE

Subjects will continue using their own insulin pump for 6 months.

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

FlorenceM (US) and FlorenceX (UK)

The automated closed loop system (FlorenceM in US) will consist of:

Next generation sensor augmented Medtronic insulin pump 640G (Medtronic Minimed, CA, USA) incorporating the Medtronic Guardian3 CGM and glucose suspend feature.

The automated closed loop system (FlorenceX in UK) will consist of:

The DANA Diabecare R insulin pump (Sooil Development, Korea) incorporating the Dexcom G6 CGM.

An Android smartphone containing the Cambridge model predictive algorithm and communicating wirelessly with the insulin pump using a proprietary translator device.

Intervention Type DEVICE

Insulin pump therapy

Subjects will continue using their own insulin pump for 6 months.

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

1. Age ≥6 and \<19 years
2. Type 1 diabetes as defined by WHO (51) for at least 1 year \[WHO definition: 'The aetiological type named type 1 encompasses the majority of cases with are primarily due to beta-cell destruction, and are prone to ketoacidosis. Type 1 includes those cases attributable to an autoimmune process, as well as those with beta-cell destruction for which neither an aetiology nor a pathogenesis is known (idiopathic). It does not include those forms of beta-cell destruction or failure to which specific causes can be assigned (e.g. cystic fibrosis, mitochondrial defects, etc.).'\]
3. Use of an insulin pump for at least 3 months, with good knowledge of insulin self-adjustment by subject or caregiver as judged by the investigator
4. Using U-100 rapid acting insulin analogues insulin Aspart or Lispro only
5. Willing to perform regular finger-prick blood glucose monitoring, with at least 4 blood glucose measurements per day day
6. Screening HbA1c ≥ 7.0% (53 mmol/mol) and ≤10 % (86mmol/mol) based on analysis from local laboratory
7. Literate in English
8. Willing to wear glucose sensor
9. Willing to wear closed-loop system at home
10. Willing to follow study specific instructions
11. Willing to upload pump and CGM data at regular intervals
12. Access to WiFi.
13. Lives with someone who is trained to administer intramuscular glucagon and is able to seek emergency assistance

Exclusion Criteria

1. Living alone
2. Current use of any closed-loop system
3. Any other physical or psychological disease likely to interfere with the normal conduct of the study and interpretation of the study results as judged by the investigator
4. Untreated coeliac disease, adrenal insufficiency, or untreated thyroid disease
5. Current treatment with drugs known to interfere with glucose metabolism, e.g. systemic corticosteroids, non-selective beta-blockers and MAO inhibitors etc.
6. Known or suspected allergy to insulin
7. Clinically significant nephropathy (eGFR \< 45ml/min) or on dialysis, neuropathy or active retinopathy (defined as presence of maculopathy or proliferative changes) as judged by the investigator
8. Recurrent incidents of severe hypoglycaemia (\>1 episode) during the previous 6 months (adolescents: severe hypoglycaemia is defined as an event requiring assistance of another person to actively administer carbohydrates, glucagon, or take other corrective actions including episodes of hypoglycaemia severe enough to cause unconsciousness, seizures or attendance at hospital; children: severe hypoglycaemia is defined as an event associated with a seizure or loss of consciousness)
9. Recurrent incidents of diabetic ketoacidosis (\>1 episode) during previous 6 months
10. Unwilling to avoid regular use of acetaminophen
11. Lack of reliable telephone facility for contact
12. Total daily insulin dose ≥ 2 IU/kg/day
13. Total daily insulin dose \< 15 IU/day
14. Pregnancy, planned pregnancy, or breast feeding
15. Severe visual impairment
16. Severe hearing impairment
17. Seizure disorder
18. Medically documented allergy towards the adhesive (glue) of plasters or unable to tolerate tape adhesive in the area of sensor placement
19. Serious skin diseases (e.g. psoriasis vulgaris, bacterial skin diseases) located at places of the body, which potentially are possible to be used for localisation of the glucose sensor)
20. Illicit drugs abuse
21. Subject is currently abusing prescription drugs
22. Alcohol abuse
23. Use of pramlintide (Symlin), or other non-insulin glucose lowering agents including sulphonylureas, biguanides, DPP4-Inhibitors, , GLP-1 analogues, SGLT-1/ 2 inhibitors at time of screening
24. Shift work with working hours between 10pm and 8am
25. Sickle cell disease, haemoglobinopathy, or has received red blood cell transfusion or erythropoietin within 3 months prior to time of screening
26. Eating disorder such as anorexia or bulimia
27. Employed by Medtronic Diabetes or with immediate family members employed by Medtronic Diabetes
Minimum Eligible Age

6 Years

Maximum Eligible Age

18 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

National Institute of Diabetes and Digestive and Kidney Diseases (NIDDK)

NIH

Sponsor Role collaborator

Cambridge University Hospitals NHS Foundation Trust

OTHER

Sponsor Role collaborator

University of Colorado, Denver

OTHER

Sponsor Role collaborator

Indiana University

OTHER

Sponsor Role collaborator

The Leeds Teaching Hospitals NHS Trust

OTHER

Sponsor Role collaborator

Stanford University

OTHER

Sponsor Role collaborator

Yale University

OTHER

Sponsor Role collaborator

Nemours Children's Health System

OTHER

Sponsor Role collaborator

Jaeb Center for Health Research

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Responsibility Role SPONSOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Roman Hovorka, PhD

Role: STUDY_CHAIR

University of Cambridge

Ajay Thankamony, MD

Role: PRINCIPAL_INVESTIGATOR

University of Cambridge

Fiona Campbell, MD

Role: PRINCIPAL_INVESTIGATOR

The Leeds Teaching Hospitals NHS Trust

Bruce Buckingham, MD

Role: PRINCIPAL_INVESTIGATOR

Stanford University

Stuart Weinzimer, MD

Role: PRINCIPAL_INVESTIGATOR

Yale University

Linda DiMeglio, MD

Role: PRINCIPAL_INVESTIGATOR

Indiana University

Paul Wadwa, MD

Role: PRINCIPAL_INVESTIGATOR

University of Colorado, Denver

Korey Hood, PhD

Role: PRINCIPAL_INVESTIGATOR

Stanford University

Dana Goldman, PhD

Role: PRINCIPAL_INVESTIGATOR

University of Southern California

Nikki C Davis, MD

Role: PRINCIPAL_INVESTIGATOR

Southampton Children's Hospital

Louise Denvir, MD

Role: PRINCIPAL_INVESTIGATOR

Nottingham Children's Hospital

Nelly Mauras, MD

Role: PRINCIPAL_INVESTIGATOR

Nemours Children's Health System

Rachel Besser, MD

Role: PRINCIPAL_INVESTIGATOR

Oxford Children's Hospital

Atrayee Ghatak, MD

Role: PRINCIPAL_INVESTIGATOR

Alder Hey Children's NHS Foundation Trust

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Stanford University

Palo Alto, California, United States

Site Status

University of Colorado Denver School of Medicine Barbara Davis Center

Aurora, Colorado, United States

Site Status

Yale University

Hartford, Connecticut, United States

Site Status

Nemours Children's Health System

Jacksonville, Florida, United States

Site Status

Indiana University

Indianapolis, Indiana, United States

Site Status

University of Cambridge

Cambridge, Cambridgeshire County, United Kingdom

Site Status

Nottingham Children's Hospital

Nottingham, England, United Kingdom

Site Status

Southampton Children's Hospital

Southampton, England, United Kingdom

Site Status

The Leeds Teaching Hospitals NHS Trust

Leeds, West Yorkshire, United Kingdom

Site Status

Alder Hey Children's NHS Foundation Trust

Liverpool, , United Kingdom

Site Status

Oxford Children's Hospital

Oxford, , United Kingdom

Site Status

Countries

Review the countries where the study has at least one active or historical site.

United States United Kingdom

References

Explore related publications, articles, or registry entries linked to this study.

Ware J, Boughton CK, Allen JM, Wilinska ME, Tauschmann M, Denvir L, Thankamony A, Campbell FM, Wadwa RP, Buckingham BA, Davis N, DiMeglio LA, Mauras N, Besser REJ, Ghatak A, Weinzimer SA, Hood KK, Fox DS, Kanapka L, Kollman C, Sibayan J, Beck RW, Hovorka R; DAN05 Consortium. Cambridge hybrid closed-loop algorithm in children and adolescents with type 1 diabetes: a multicentre 6-month randomised controlled trial. Lancet Digit Health. 2022 Apr;4(4):e245-e255. doi: 10.1016/S2589-7500(22)00020-6. Epub 2022 Mar 7.

Reference Type DERIVED
PMID: 35272971 (View on PubMed)

Musolino G, Allen JM, Hartnell S, Wilinska ME, Tauschmann M, Boughton C, Campbell F, Denvir L, Trevelyan N, Wadwa P, DiMeglio L, Buckingham BA, Weinzimer S, Acerini CL, Hood K, Fox S, Kollman C, Sibayan J, Borgman S, Cheng P, Hovorka R. Assessing the efficacy, safety and utility of 6-month day-and-night automated closed-loop insulin delivery under free-living conditions compared with insulin pump therapy in children and adolescents with type 1 diabetes: an open-label, multicentre, multinational, single-period, randomised, parallel group study protocol. BMJ Open. 2019 Jun 3;9(6):e027856. doi: 10.1136/bmjopen-2018-027856.

Reference Type DERIVED
PMID: 31164368 (View on PubMed)

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

1UC4DK108520-01

Identifier Type: NIH

Identifier Source: secondary_id

View Link

DAN05

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.