Radiation Exposure of ERCP Personnel at Different Standing Locations and Different Patient Positions.

NCT ID: NCT02791659

Last Updated: 2017-05-30

Study Results

Results available

Outcome measurements, participant flow, baseline characteristics, and adverse events have been published for this study.

View full results

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Clinical Phase

NA

Total Enrollment

55 participants

Study Classification

INTERVENTIONAL

Study Start Date

2016-07-31

Study Completion Date

2016-11-30

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

X-ray beam produced during endoscopic retrograde cholangiopancreatography (ERCP) affect not only the patient, but the personnel of ERCP team may have the effect from the scattered ray. According to the automatic beam adjustment function, the thicker object (eg. lying left lateral) might produce higher scatter ray than thinner object (eg. lying prone). The investigators evaluate the radiation exposure among ERCP personnel compare between patient's 2 different positions.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Personal solid-state dosimeters were used to measure the radiation dose on personnel during ERCP procedure. The real-time effective doses were displayed at a monitoring screen. A dosimeter was attached outside thyroid collar of each ERCP team member included of 1st endoscopist, 2nd endoscopist, and nurse anesthetist.

Patients' age, gender, BMI, body thickness, and indications for ERCP were recorded. The patients were randomized into 2 groups by block-of-four. The patients' position was assigned to prone or left lateral decubitus. Each ERCP personnel wore a lead apron and the dosimeter was attached outside the thyroid collar. The ERCP procedure was performed according to the indication in a standard technique. After ERCP procedure, the total fluoroscopic time (minute), fluoroscopy tube voltage (kV), fluoroscopy tube current (mA), patient entrance skin dose (mGy) and personnel effective dose (Sv) from each dosimeter were recorded.

Continuous variables were compared by Student's t-test or Man Whitney U-test, where appropriate. Categorical variables were compared by Chi-square or the Fisher exact test. Statistical analysis was calculated by using SPSS statistical software (version17 for Window, Chicago, USA) and two sided p-value \< 0.05 was considered to be statistical significant.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Occupational Radiation Exposure

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

RANDOMIZED

Intervention Model

PARALLEL

Primary Study Purpose

OTHER

Blinding Strategy

NONE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Left lateral decubitus

In this group, the position will be assigned to Left lateral decubitus during ERCP. The radiation from fluoroscopy will be adjusted by automatic beam adjustment function to obtain the image quality.

Group Type ACTIVE_COMPARATOR

Automatic beam adjustment function

Intervention Type RADIATION

The fluoroscopy system has an automatic beam adjustment function to maintain a good quality of image output.

Prone

In this group, the position will be assigned to Prone during ERCP. The radiation from fluoroscopy will be adjusted by automatic beam adjustment function to obtain the image quality.

Group Type EXPERIMENTAL

Automatic beam adjustment function

Intervention Type RADIATION

The fluoroscopy system has an automatic beam adjustment function to maintain a good quality of image output.

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Automatic beam adjustment function

The fluoroscopy system has an automatic beam adjustment function to maintain a good quality of image output.

Intervention Type RADIATION

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Indicated for ERCP

Exclusion Criteria

* pregnancy
* American Society of Anesthesiologists (ASA) physical status class III - IV
* unstable vital signs
* patients' position needed to be changed during the procedure
* patients who need fixed position for ERCP (such as biliary hilar lesion)
* enteroscope-assisted ERCP
* the consent form can not be obtained
Minimum Eligible Age

18 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Chulalongkorn University

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Responsibility Role SPONSOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Rungsun Rerknimitr, MD, FRCP

Role: PRINCIPAL_INVESTIGATOR

Chulalongkorn University

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

PA-E-RAD002

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

Ga-68 Dolacga PET Scan in HCC Under RFA
NCT06792097 NOT_YET_RECRUITING