Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
NA
59 participants
INTERVENTIONAL
2016-08-31
2017-06-30
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
The aim of this study is to assess the effects of transvaginal ultrasound training when orienting the image top-down versus bottom-up, which can open for the discussion concerning a uniform transvaginal ultrasound education. This study may improve ultrasound novices' learning and potentially ensure that future clinicians perform transvaginal ultrasound examinations in the same manner.
Hypotheses: The investigators hypothesize that the orientation perceived by ultrasound novices, as the most intuitive will result in lower cognitive load during training and result in shorter learning curves and improved transfer of skills to various settings and cases.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Transvaginal Ultrasound Training for Obstetrics and Gynecology Residents
NCT02890914
Transfer From a Point-of-care Ultrasound Course
NCT02304133
Simulation-based Ultrasound Training to Improve Patient Comfort and Decrease the Need for Re-examination. A Randomized Trial.
NCT01801462
Comparative Study of Learning Curve for First Trimester Fetal Anomaly Scan
NCT04707456
Influence of Imaging Angle in Measurement of Cisterna Magna
NCT03697902
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Ultrasonography is considered safe but highly operator dependent. Ultrasonography is being used increasingly in gynecology and obstetrics; however the training of novices in transvaginal ultrasound is performed differently with respect to the orientation of the ultrasound image, which often differs between operators and institutions. The image may be oriented top- down (transducer at the top) or bottom-up (transducer at the bottom). The different orientations of the image are a challenge for novices when being supervised by senior clinicians with different preferences for image orientation. As for now, there is no international consensus on image orientation and there is no evidence to support the superiority of one over the other in terms of learning curves and educational outcomes such as skills transfer. Transvaginal ultrasound is, like all other kinds of ultrasound, associated with long learning curves and is therefore time-consuming and requires extensive training. Transvaginal ultrasound is often associated with some discomfort to the patient, which can be reduced with adequate initial training. It therefore seems reasonable to determine how to provide the most effective initial transvaginal ultrasound training to reduce unnecessary patient discomfort and improve diagnostic accuracy through accelerated learning curves.
A recent study involving laparoscopic training, suggests that novices learn best from simplified practice during initial skills acquisition because it allows them to deal with future task complexity better than when being faced with complex image orientation. These findings are consistent with cognitive load theory, which emphasizes the limitations of the working memory when learning new tasks. Optimal learning occurs when the cognitive load of a new task is within the limits of the learner's working memory and when instructional features that do not contribute to learning are eliminated. Basic knobology (operating the ultrasound machine controls) and image interpretation represent significant sources of cognitive load for ultrasound novices and the acquisition of images should therefore be as simple as possible to avoid exceeding the working memory of the learner.
When looking at an ultrasound image, the operator transforms the two-dimensional ultrasound image into a three-dimensional internal representation of the structure being examined. Alignment of the image according to the physical angle of the transvaginal ultrasound probe by having the image facing bottom-up is by some clinicians perceived as the most intuitive anatomical orientation. Other clinicians prefer having the ultrasound image oriented the same way (top-down) regardless of the type of examination being performed (transabdominal or transvaginal).
The research question in this study is:
In a group of ultrasound novices, what is the effect of the transvaginal ultrasound training when orienting the image top-down versus bottom-up on learning curves and transfer of skills to different settings and cases?
Hypotheses:
The investigators hypothesize that the orientation perceived by ultrasound novices as the most intuitive will also result in shorter learning curves and improved transfer of skills. This study may improve ultrasound novices' learning and ensure that future clinicians perform transvaginal ultrasound examinations in the same manner. If the orientation of the image does not result in any changes to educational outcomes, there is no argument for adopting one approach over the other from an educational point-of-view.
Participants
Participants in this study are medical students from the University of Copenhagen, Denmark. Inclusion criteria require that participants 1) are medical students from year 3 to year 6; 2) have no previous ultrasound experience besides a mandatory ultrasound course of four hours provided at the 6th semester for medical students at the University of Copenhagen; and 3) provide written informed consent. Participants are after inclusion randomly divided into two study groups:
1. Group one (TD): Orienting the transvaginal ultrasound image top-down
2. Group two (BU): Orienting the transvaginal ultrasound image bottom-up
Randomization An independent research fellow at the Copenhagen Academy for Medical Education and Simulation, Rigshospitalet, randomizes participants by computer to either of the two groups.
Intervention Before any training is commenced, all participants are surveyed on their intuitive preferences for image orientation. Participants in both groups then receive a short theoretical introduction to pelvic ultrasound. Afterwards the participants are introduced to the simulated environment and the Virtual Reality (VR) simulator (Scantrainer) used for training. The VR simulator provides images obtained from real patients and haptic feedback from the ultrasound probe.
The study is based on the principle of mastery learning, thus participants are instructed to complete a simulator test that includes a number of practice modules until they have reached expert levels of performance. The expert performance level has been established in a previous validation study. Participants in the TD and BU groups are instructed with the ultrasound image top-down and bottom-up, respectively, throughout all training and assessment.
When the expert level is reached the participants perform a transfer test on the low-fidelity simulator (BluePhantom) within 7 days of completed simulator training. During the transfer test participants will be asked to complete a systematic ultrasound examination and to optimize the images during the scan. The performances will be videotaped and afterwards rated by two clinicians used to perform transvaginal ultrasound - one clinician used to seeing the ultrasound image top-down and the other clinician used to seeing the image bottom-up. The participants will be rated using the Objective Structured Assessment of Ultrasound Skills.
After completed training, participants are assessed on their cognitive load using a cognitive load questionnaire.
All training and assessments take place in the simulated setting in the skills lab at Copenhagen Academy for Medical Education and Simulation, Rigshospitalet.
Outcomes
Primary outcome:
• The primary outcome measures include learning curve for the two groups and performances during the transfer test. Learning curves are assessed through simulator scores obtained on the practice modules. A previous study has demonstrated that mastery learning levels are attained after four to five rounds of training on the practice modules included in the simulator test
Secondary outcomes:
* Participants' perception of the most intuitive approach before training.
* Time used within the two groups to reach expert level
* Cognitive load measurements using the instrument described by Leppink et al. after training
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
RANDOMIZED
PARALLEL
OTHER
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Top-down (TD)
The group having the transvaginal ultrasound image top-down. During training and transfer test.
Ultrasound training
Training on the transvaginal ultrasound simulator.
Bottom-up (BU)
The group having the transvaginal ultrasound image bottom-up. During training and transfer test.
Ultrasound training
Training on the transvaginal ultrasound simulator.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Ultrasound training
Training on the transvaginal ultrasound simulator.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
2. provide written informed consent.
Exclusion Criteria
ALL
Yes
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Rigshospitalet, Denmark
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Caroline Amalie Taksoe-Vester
Stud.med
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Caroline A Taksoe-Vester, Bach.med
Role: PRINCIPAL_INVESTIGATOR
Student teacher
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
12345
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.