Thoraflex™ Hybrid IDE Study

NCT ID: NCT02724072

Last Updated: 2022-05-16

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Clinical Phase

NA

Total Enrollment

84 participants

Study Classification

INTERVENTIONAL

Study Start Date

2016-08-22

Study Completion Date

2021-07-30

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

The study will assess the effectiveness, safety and clinical outcomes of the Thoraflex™ Hybrid Device in the treatment of aortic disease affecting the aortic arch and the descending thoracic aorta, with or without involvement of ascending aorta.

The study will also assess safety and early clinical outcomes in patients who receive an extension procedure within 1 year of Thoraflex™ Hybrid Device implantation.

Lastly the study will assess the safety and clinical outcomes of patients who receive a Thoraflex™ Hybrid Device for treatment of a ruptured aorta.

Patients will be followed for 3 years.

The Primary Endpoint will be freedom from defined Major Adverse Events (MAE) occurring ≤ 1 year post-procedure.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Vascutek Ltd has developed the Thoraflex™ Hybrid Device (Plexus™ 4 and Ante-Flo™) for the open surgical repair or replacement of damaged or diseased vessels of the aortic arch and descending aorta, with or without involvement of the ascending aorta, in cases of aneurysm and/or dissection. The Thoraflex™ Hybrid Device may be considered a development of the Elephant Trunk (ET) grafts with the addition of a stented distal section. In some cases this will allow for a single stage procedure to be carried out, dependent on the length of affected vessel. As the device is fully sealed and has a collar to aid anastomosis, it removes the requirement for in situ sealing and the suturing together of two devices, thereby reducing cardiopulmonary bypass (CPB) time and overall procedure time.

By reducing the procedure time and negating the need for as many subsequent procedures, this method could greatly improve the success of this procedure and may improve patient outcomes.

The ability to treat complex anatomies in addition to reducing procedure and CPB time, justify the investigation of the Thoraflex™ Hybrid Device. Safety and effectiveness data for subjects treated with the Thoraflex™ Hybrid Device will be compared to historical data from subjects treated using standard ET surgical repair.

It is anticipated that up to 83 patients will be recruited over a 14 month period (approximately). Patients will be evaluated at the following time points: Pre-procedure, Implant, Discharge/30 days, 3 months, 12 months, 24 months and 36 months. An additional visit may be performed for patients who undergo an extension procedure within 1 year of Thoraflex™ Hybrid Device implantation.

65 patients will be recruited to the primary study group (maximum 19 per site). An additional group of patients with a ruptured aorta may also be recruited (up to approximately 18 patients across all sites).

A historical control population has been derived from a comparable patient population who received treatment for thoracic aortic disease using the current standard of care, which is the conventional (2-stage) elephant trunk technique. Using data from the comparator population a Performance Goal Target has been set at 57.4%.

The study will be deemed a success if the lower limit of the 95% confidence interval, associated with the proportion of study patients who are free from the defined composite Major Adverse Events (permanent stroke, permanent paraplegia/paraparesis, unanticipated aortic related re-operation and all-cause mortality) at 1 year post procedure, is greater than 57.4%. Only patients included in the main study group will be included in the Performance Goal Analysis; patients recruited into the additional Aortic Rupture group will not be included in the primary endpoint analysis. All patients in the main study group will be included in the analysis regardless of whether or not an extension procedure has been performed.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Aortic Aneurysm Aortic Dissection Aortic Rupture

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

NA

Intervention Model

SINGLE_GROUP

Primary Study Purpose

TREATMENT

Blinding Strategy

NONE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Thoraflex™ Hybrid Device.

Plexus™ 4 and Ante-Flo™ configurations will be included in this study.

Group Type EXPERIMENTAL

Thoraflex™ Hybrid Device

Intervention Type DEVICE

Single-use medical device sterilized by ethylene oxide which is pre-loaded into a delivery system. The device comprises a gelatin sealed vascular graft combined with a stented graft.

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Thoraflex™ Hybrid Device

Single-use medical device sterilized by ethylene oxide which is pre-loaded into a delivery system. The device comprises a gelatin sealed vascular graft combined with a stented graft.

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

Main Study Group (All patients except Aortic Rupture Patients)

* Patient is aged 18 years or over on date of consent
* Patient is willing and able to comply with all study procedures and study visits
* Patient or their legally authorized representative has given written informed consent to participate in study

A - Patient has acute dissection of the aorta or B - Patient has chronic dissection of the aorta or C - Patient has an aortic aneurysm (including connective tissue disorders)

A. - Patients with acute dissection of the aorta:

•Patient has acute aortic dissection and requires repair or replacement of damaged or diseased vessels of the aortic arch (with or without involvement of the ascending aorta), and the descending aorta requires replacement, or, in the opinion of the investigator, the patient would derive clinical benefit from prophylactic treatment of the descending aorta.

B. - Patients with chronic dissection of the aorta:

•Patient requires repair or replacement of damaged or diseased vessels of the aortic arch and descending aorta with or without involvement of the ascending aorta due to chronic dissection.

And patient satisfies one or more of the following criteria:

* Patient has aortic sinus, or ascending aorta, or aortic arch, or descending aorta diameter ≥5.5cm (including if asymptomatic) or
* Patient has aorta diameter \<5.5cm and growth rate ≥0.5cm/year (including if asymptomatic) or
* Patient has ascending aorta diameter ≥4.5cm and requires valve repair or replacement

C. - Patients with an aortic aneurysm (including connective tissue disorders):

•Patient requires repair or replacement of damaged or diseased vessels of the aortic arch and descending aorta with or without involvement of the ascending aorta

And patient satisfies one or more of the following criteria:

* Patient has aortic sinus, or ascending aorta, or aortic arch, or descending aorta diameter ≥5.5cm (including if asymptomatic) or
* Patient has aorta diameter \<5.5cm and growth rate ≥0.5cm/year(including if asymptomatic) or
* Patient has ascending aorta diameter ≥4.5cm and requires valve repair or replacement or
* Patient has Marfan syndrome or other genetically mediated disorders with aortic sinus, or ascending aorta, or arch diameter ≥4.5cm, or, the ratio of the maximal ascending or aortic root area (Π r2) in cm2 divided by the patient's height in meters exceeds 10


* Patient is aged 18 years or over, on date of consent
* Patient or their legally authorized representative is able and willing to give consent to the patient's enrolment in the study
* Patient has either a ruptured thoracic aorta, or, in the experience of the treating surgeon, is at high risk of imminent rupture of the thoracic aorta

Exclusion Criteria

Main Study Group (All Patients Except Patients with Ruptured Aorta)

* Patient is unfit for open surgical repair involving circulatory arrest
* Patient has known sensitivity to polyester, nitinol or materials of bovine origin
* Patient has a ruptured aorta
* Patient has active endocarditis or an active infective disorder of the aorta
* Patient has an active systemic infection that, in the opinion of the investigator, would compromise the outcome of the surgical procedure
* Patient is enrolled in another active study and has received an investigational product (device, pharmaceutical or biologic) within 6 months prior to the date of the implant or has not reached the primary endpoint of the study
* Patient is female and is pregnant, or planning to become pregnant during the course of the study. Females of childbearing potential must use acceptable methods of contraception.
* Patient has an uncorrectable bleeding anomaly
* Patient has renal failure (defined as dialysis dependent or serum creatinine ≥2.5mg/dL)
* Patient has known sensitivity to radiopaque contrast agents that cannot be adequately pre-treated
* Patient has a co-morbidity causing expected survival to be less than 1 year
* Patient has any other medical, social or psychological problems that in the opinion of the investigator preclude them from receiving this treatment and the procedures and evaluations pre and post procedure


* Patient has chronic dissection which, in the opinion of the investigator, can be treated electively
* Patient has aneurysmal disease which, in the opinion of the investigator, can be treated electively
Minimum Eligible Age

18 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Vascutek Ltd.

INDUSTRY

Sponsor Role collaborator

Bolton Medical

INDUSTRY

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Responsibility Role SPONSOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Joseph S Coselli

Role: PRINCIPAL_INVESTIGATOR

Baylor St. Luke's

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Stanford University Medical Center

Palo Alto, California, United States

Site Status

Emory Saint Joseph's Hospital

Atlanta, Georgia, United States

Site Status

Northwestern Memorial Hospital

Chicago, Illinois, United States

Site Status

University of Michigan

Ann Arbor, Michigan, United States

Site Status

The Mount Sinai Hospital

New York, New York, United States

Site Status

Columbia University Medical Center

New York, New York, United States

Site Status

NY Presbyterian Weill Cornell

New York, New York, United States

Site Status

Cleveland Clinic

Cleveland, Ohio, United States

Site Status

University of Pennsylvania

Philadelphia, Pennsylvania, United States

Site Status

University of Pittsburgh Medical Center (UPMC) Presbyterian

Pittsburgh, Pennsylvania, United States

Site Status

Baylor St. Luke's

Houston, Texas, United States

Site Status

University of Texas Houston- Memorial Hermann Texas Medical Center

Houston, Texas, United States

Site Status

Countries

Review the countries where the study has at least one active or historical site.

United States

Related Links

Access external resources that provide additional context or updates about the study.

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

HYBRID-002

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

TORUS 2 IDE Clinical Study
NCT04130737 ACTIVE_NOT_RECRUITING NA