In-line Filtration to Reduce Systemic Inflammatory Response Syndrome in Babies Born Very prEtErm
NCT ID: NCT02686060
Last Updated: 2023-02-03
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
NA
160 participants
INTERVENTIONAL
2016-04-30
2017-11-30
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Infusion therapy carries a risk for catheter-associated septicaemia (Geiss 1992) originated from the catheter tubing, the ports, at the cannula site or from contaminated infusion fluid. While not all infections lead to septicaemia, immuno-compromised patients such as neonates are at greater risk, and infection becomes a major problem (Ng 1989) and a major risk factor for neurodevelopmental disabilities (Volpe 2008). Indeed, it has been postulated that endotoxins may be involved in the pathogenesis of a proportion of cases of periventricular leukomalacia, the most frequent brain damage associated with neurocognitive handicaps in the human neonate (Volpe 2001).
The presence of calcium in parenteral nutrition mixture leads to precipitation due to its incompatibility with the other components of the admixtures and leads to high concentration of particles (Athanasiou 2014). Adverse systemic effects of particulate matter including phlebitis, granulomata formation in the lung (Marshall 1987) and ischaemic necrosis, are a common finding in necrotizing enterocolitis another serious complication flowing preterm birth (Ballance 1990). Particle contamination of infusion solutions exists despite a stringent infusion regiment. The number and composition of particles depends on the complexity of the applied admixtures (Jack 2010).
Particulate contamination is due to drug incompatibility reactions or their incomplete reconstitution during the preparation process (Schroder 1994). Various studies have demonstrated the contamination of infusion solutions with glass particles from opening glass ampoules, particles from rubber stoppers or conglomerates of the parenteral nutrition components (Ball 2003). Particles have also been shown to be inherent to generic drug formulation (Oie 2005). In an intensive care setting the particle burden may rise up to one million infused particles per day, increasing with the complexity and quantity of the administered infusions (Walpot 1989).
There are two main IV filter pore sizes; the 0.2 micron filter is used for aqueous solutions, and the 1.2 micron filter is recommended for larger molecule solutions such as lipids. The 0.2 micron filter has also been reported to remove air, microorganisms and particulate matter. In addition, endotoxin retention is reportedly achieved by using a positively charged filter membrane; toxic macro-molecules are released by gram-negative bacteria and are claimed to be effective for up to ninety six hours (Bethune 2001).
In-line IV filters are currently claimed to be an effective strategy for the removal of bacteria, endotoxins and particulates associated with intravenous therapy in adults (Ball 2003) and particularly effective in the removal of particles caused from drug precipitate such as antibiotics (Chee 2002; Ball 2003).
However, evidence of the beneficial effect of in-line IV filters in children and neonates is much weaker, despite some positive studies (Jack 2012; Boehne 2013; Sasse 2015). In the population of preterm infants, no study is currently available while particulate contamination due to infusion therapy carries a higher health risk in this subpopulation.
The benefits of using IV in-line filters in critically-ill preterm neonates remains to be demonstrated. This intervention in adults has also been challenged by several authors (Pearson 1996; Newell 1998). Friedland reported that certain drugs such as antibiotics may be retained in the filters causing a reduction in potency (Friedland 1985). On the other hand, there are no known adverse effects from the use of IV in-line filters.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Preventing Catheter-related Bacteremia When Administering Injectable Medications in Premature Infants.
NCT02633124
Impact of a Multi-infusion Strategy in Neonatology on the Rate of Central Line-associated Bloodstream Infections
NCT06656104
Intravenous Neonatal Central Access Safety Trial
NCT05537389
Microfluidic Assessment of Clinical Outcomes in Preterm Newborns
NCT03291496
Comparison Between Split Septum and Mechanical Valve Needleless Connector in Preterm Babies
NCT06414174
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Infusion therapy carries a risk for catheter-associated septicaemia (Geiss 1992) originated from the catheter tubing, the ports, at the cannula site or from contaminated infusion fluid. While not all infections lead to septicaemia, immuno-compromised patients such as neonates are at greater risk, and infection becomes a major problem (Ng 1989) and a major risk factor for neurodevelopmental disabilities (Volpe 2008). Indeed, it has been postulated that endotoxins may be involved in the pathogenesis of a proportion of cases of periventricular leukomalacia, the most frequent brain damage associated with neurocognitive handicaps in the human neonate (Volpe 2001).
The presence of calcium in parenteral nutrition mixture leads to precipitation due to its incompatibility with the other components of the admixtures and leads to high concentration of particles (Athanasiou 2014). Adverse systemic effects of particulate matter including phlebitis, granulomata formation in the lung (Marshall 1987) and ischaemic necrosis, are a common finding in necrotizing enterocolitis another serious complication flowing preterm birth (Ballance 1990). Particle contamination of infusion solutions exists despite a stringent infusion regiment. The number and composition of particles depends on the complexity of the applied admixtures (Jack 2010).
Particulate contamination is due to drug incompatibility reactions or their incomplete reconstitution during the preparation process (Schroder 1994). Various studies have demonstrated the contamination of infusion solutions with glass particles from opening glass ampoules, particles from rubber stoppers or conglomerates of the parenteral nutrition components (Ball 2003). Particles have also been shown to be inherent to generic drug formulation (Oie 2005). In an intensive care setting the particle burden may rise up to one million infused particles per day, increasing with the complexity and quantity of the administered infusions (Walpot 1989).
There are two main IV filter pore sizes; the 0.2 micron filter is used for aqueous solutions, and the 1.2 micron filter is recommended for larger molecule solutions such as lipids. The 0.2 micron filter has also been reported to remove air, microorganisms and particulate matter. In addition, endotoxin retention is reportedly achieved by using a positively charged filter membrane; toxic macro-molecules are released by gram-negative bacteria and are claimed to be effective for up to ninety six hours (Bethune 2001).
In-line IV filters are currently claimed to be an effective strategy for the removal of bacteria, endotoxins and particulates associated with intravenous therapy in adults (Ball 2003) and particularly effective in the removal of particles caused from drug precipitate such as antibiotics (Chee 2002; Ball 2003).
However, evidence of the beneficial effect of in-line IV filters in children and neonates is much weaker, despite some positive studies (Jack 2012; Boehne 2013; Sasse 2015). In the population of preterm infants, no study is currently available while particulate contamination due to infusion therapy carries a higher health risk in this subpopulation.
The benefits of using IV in-line filters in critically-ill preterm neonates remains to be demonstrated. This intervention in adults has also been challenged by several authors (Pearson 1996; Newell 1998). Friedland reported that certain drugs such as antibiotics may be retained in the filters causing a reduction in potency (Friedland 1985). On the other hand, there are no known adverse effects from the use of IV in-line filters.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
RANDOMIZED
PARALLEL
PREVENTION
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
in-line filters
0.2 micron positively charged PALL Corporation filters for parenteral nutrition (Posidyne® NEO Intravenous Filter Set) and 1.2 micro IV in-line filters used for lipid administration (Lipipor™ NEO Filters for Neonatal Parenteral Nutrition)
0.2 micron positively charged PALL Corporation filters and 1.2 micro IV in-line filters used for lipid administration
without in-line filters.
No interventions assigned to this group
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
0.2 micron positively charged PALL Corporation filters and 1.2 micro IV in-line filters used for lipid administration
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Neonates whose parental authority holders have been informed for the study \& do not opposite to participate,
* Neonates whose parental authority holders are covered by the social security system or CMU.
Exclusion Criteria
* Congenital malformation and/or heart diseases other than patent ductus arteriosus or foramen ovale,
* "Outborn" neonates,
* Newborns whose parental authority holders are minor,
* Newborns with severe birth asphyxia (cord blood pH\<7.0 or Apgar score \< 5 at 10 min),
* Newborns whose parental authority holders are not beneficiaries of social security coverage.
24 Weeks
32 Weeks
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Assistance Publique - Hôpitaux de Paris
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Hopital Robert Debre
Paris, , France
Countries
Review the countries where the study has at least one active or historical site.
References
Explore related publications, articles, or registry entries linked to this study.
Virlouvet AL, Pansiot J, Toumazi A, Colella M, Capewell A, Guerriero E, Storme T, Rioualen S, Bourmaud A, Biran V, Baud O. In-line filtration in very preterm neonates: a randomized controlled trial. Sci Rep. 2020 Mar 19;10(1):5003. doi: 10.1038/s41598-020-61815-4.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
2015-A01307-42
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.