In-line Filtration to Reduce Systemic Inflammatory Response Syndrome in Babies Born Very prEtErm

NCT ID: NCT02686060

Last Updated: 2023-02-03

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Clinical Phase

NA

Total Enrollment

160 participants

Study Classification

INTERVENTIONAL

Study Start Date

2016-04-30

Study Completion Date

2017-11-30

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

While venous access is an essential part of caring for the preterm neonate potential severe adverse events, including contamination of fluids with bacteria, endotoxins and particulates could occur (Bethune 2001).

Infusion therapy carries a risk for catheter-associated septicaemia (Geiss 1992) originated from the catheter tubing, the ports, at the cannula site or from contaminated infusion fluid. While not all infections lead to septicaemia, immuno-compromised patients such as neonates are at greater risk, and infection becomes a major problem (Ng 1989) and a major risk factor for neurodevelopmental disabilities (Volpe 2008). Indeed, it has been postulated that endotoxins may be involved in the pathogenesis of a proportion of cases of periventricular leukomalacia, the most frequent brain damage associated with neurocognitive handicaps in the human neonate (Volpe 2001).

The presence of calcium in parenteral nutrition mixture leads to precipitation due to its incompatibility with the other components of the admixtures and leads to high concentration of particles (Athanasiou 2014). Adverse systemic effects of particulate matter including phlebitis, granulomata formation in the lung (Marshall 1987) and ischaemic necrosis, are a common finding in necrotizing enterocolitis another serious complication flowing preterm birth (Ballance 1990). Particle contamination of infusion solutions exists despite a stringent infusion regiment. The number and composition of particles depends on the complexity of the applied admixtures (Jack 2010).

Particulate contamination is due to drug incompatibility reactions or their incomplete reconstitution during the preparation process (Schroder 1994). Various studies have demonstrated the contamination of infusion solutions with glass particles from opening glass ampoules, particles from rubber stoppers or conglomerates of the parenteral nutrition components (Ball 2003). Particles have also been shown to be inherent to generic drug formulation (Oie 2005). In an intensive care setting the particle burden may rise up to one million infused particles per day, increasing with the complexity and quantity of the administered infusions (Walpot 1989).

There are two main IV filter pore sizes; the 0.2 micron filter is used for aqueous solutions, and the 1.2 micron filter is recommended for larger molecule solutions such as lipids. The 0.2 micron filter has also been reported to remove air, microorganisms and particulate matter. In addition, endotoxin retention is reportedly achieved by using a positively charged filter membrane; toxic macro-molecules are released by gram-negative bacteria and are claimed to be effective for up to ninety six hours (Bethune 2001).

In-line IV filters are currently claimed to be an effective strategy for the removal of bacteria, endotoxins and particulates associated with intravenous therapy in adults (Ball 2003) and particularly effective in the removal of particles caused from drug precipitate such as antibiotics (Chee 2002; Ball 2003).

However, evidence of the beneficial effect of in-line IV filters in children and neonates is much weaker, despite some positive studies (Jack 2012; Boehne 2013; Sasse 2015). In the population of preterm infants, no study is currently available while particulate contamination due to infusion therapy carries a higher health risk in this subpopulation.

The benefits of using IV in-line filters in critically-ill preterm neonates remains to be demonstrated. This intervention in adults has also been challenged by several authors (Pearson 1996; Newell 1998). Friedland reported that certain drugs such as antibiotics may be retained in the filters causing a reduction in potency (Friedland 1985). On the other hand, there are no known adverse effects from the use of IV in-line filters.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

While venous access is an essential part of caring for the preterm neonate potential severe adverse events, including contamination of fluids with bacteria, endotoxins and particulates could occur (Bethune 2001).

Infusion therapy carries a risk for catheter-associated septicaemia (Geiss 1992) originated from the catheter tubing, the ports, at the cannula site or from contaminated infusion fluid. While not all infections lead to septicaemia, immuno-compromised patients such as neonates are at greater risk, and infection becomes a major problem (Ng 1989) and a major risk factor for neurodevelopmental disabilities (Volpe 2008). Indeed, it has been postulated that endotoxins may be involved in the pathogenesis of a proportion of cases of periventricular leukomalacia, the most frequent brain damage associated with neurocognitive handicaps in the human neonate (Volpe 2001).

The presence of calcium in parenteral nutrition mixture leads to precipitation due to its incompatibility with the other components of the admixtures and leads to high concentration of particles (Athanasiou 2014). Adverse systemic effects of particulate matter including phlebitis, granulomata formation in the lung (Marshall 1987) and ischaemic necrosis, are a common finding in necrotizing enterocolitis another serious complication flowing preterm birth (Ballance 1990). Particle contamination of infusion solutions exists despite a stringent infusion regiment. The number and composition of particles depends on the complexity of the applied admixtures (Jack 2010).

Particulate contamination is due to drug incompatibility reactions or their incomplete reconstitution during the preparation process (Schroder 1994). Various studies have demonstrated the contamination of infusion solutions with glass particles from opening glass ampoules, particles from rubber stoppers or conglomerates of the parenteral nutrition components (Ball 2003). Particles have also been shown to be inherent to generic drug formulation (Oie 2005). In an intensive care setting the particle burden may rise up to one million infused particles per day, increasing with the complexity and quantity of the administered infusions (Walpot 1989).

There are two main IV filter pore sizes; the 0.2 micron filter is used for aqueous solutions, and the 1.2 micron filter is recommended for larger molecule solutions such as lipids. The 0.2 micron filter has also been reported to remove air, microorganisms and particulate matter. In addition, endotoxin retention is reportedly achieved by using a positively charged filter membrane; toxic macro-molecules are released by gram-negative bacteria and are claimed to be effective for up to ninety six hours (Bethune 2001).

In-line IV filters are currently claimed to be an effective strategy for the removal of bacteria, endotoxins and particulates associated with intravenous therapy in adults (Ball 2003) and particularly effective in the removal of particles caused from drug precipitate such as antibiotics (Chee 2002; Ball 2003).

However, evidence of the beneficial effect of in-line IV filters in children and neonates is much weaker, despite some positive studies (Jack 2012; Boehne 2013; Sasse 2015). In the population of preterm infants, no study is currently available while particulate contamination due to infusion therapy carries a higher health risk in this subpopulation.

The benefits of using IV in-line filters in critically-ill preterm neonates remains to be demonstrated. This intervention in adults has also been challenged by several authors (Pearson 1996; Newell 1998). Friedland reported that certain drugs such as antibiotics may be retained in the filters causing a reduction in potency (Friedland 1985). On the other hand, there are no known adverse effects from the use of IV in-line filters.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Babies Born Very Preterm

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

RANDOMIZED

Intervention Model

PARALLEL

Primary Study Purpose

PREVENTION

Blinding Strategy

NONE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

in-line filters

0.2 micron positively charged PALL Corporation filters for parenteral nutrition (Posidyne® NEO Intravenous Filter Set) and 1.2 micro IV in-line filters used for lipid administration (Lipipor™ NEO Filters for Neonatal Parenteral Nutrition)

Group Type EXPERIMENTAL

0.2 micron positively charged PALL Corporation filters and 1.2 micro IV in-line filters used for lipid administration

Intervention Type DEVICE

without in-line filters.

Group Type NO_INTERVENTION

No interventions assigned to this group

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

0.2 micron positively charged PALL Corporation filters and 1.2 micro IV in-line filters used for lipid administration

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Every newborn with a gestational age between 24+0 and 31+6 weeks of gestation or with a birth weight \<1500 gm, born at the maternity of Robert Debré children's hospital,
* Neonates whose parental authority holders have been informed for the study \& do not opposite to participate,
* Neonates whose parental authority holders are covered by the social security system or CMU.

Exclusion Criteria

* Preterm infants with a gestational age ≥ 32 weeks of gestation,
* Congenital malformation and/or heart diseases other than patent ductus arteriosus or foramen ovale,
* "Outborn" neonates,
* Newborns whose parental authority holders are minor,
* Newborns with severe birth asphyxia (cord blood pH\<7.0 or Apgar score \< 5 at 10 min),
* Newborns whose parental authority holders are not beneficiaries of social security coverage.
Minimum Eligible Age

24 Weeks

Maximum Eligible Age

32 Weeks

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Assistance Publique - Hôpitaux de Paris

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Responsibility Role SPONSOR

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Hopital Robert Debre

Paris, , France

Site Status

Countries

Review the countries where the study has at least one active or historical site.

France

References

Explore related publications, articles, or registry entries linked to this study.

Virlouvet AL, Pansiot J, Toumazi A, Colella M, Capewell A, Guerriero E, Storme T, Rioualen S, Bourmaud A, Biran V, Baud O. In-line filtration in very preterm neonates: a randomized controlled trial. Sci Rep. 2020 Mar 19;10(1):5003. doi: 10.1038/s41598-020-61815-4.

Reference Type RESULT
PMID: 32193413 (View on PubMed)

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

2015-A01307-42

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

Multiperfusion Neonatal System
NCT05058534 COMPLETED