Feasibility Study to Evaluate the Hybrid-Logic Closed Loop System in Type 1 Diabetes The DREAMED Trail
NCT ID: NCT02651181
Last Updated: 2020-01-02
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
NA
10 participants
INTERVENTIONAL
2016-06-30
2018-01-31
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Several groups around the world investigate efforts in developing closed-loop systems. Investigators combined two closed-loop systems with different mode of operation in order to enhance the closed-loop system. The two systems are Hybrid closed-loop system and the MD-Logic closed-loop system . The combined algorithm Hybrid logic closed loop (HLCL) was tested 'In silico' and was proved to be safe and effective. The next step is to test the system in a clinical study in a supervised environment in a camp.
The two systems were tested separately in several clinical studies and were proven to be safe and effective in a diverse population of patients with type 1 diabetes. The MD-Logic system for overnight use "the GlucoSitter" has a CE mark.
The purpose of this study is to collect data on the feasibility of the HLCL system in a camp setting.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Comparison of Two Closed-Loop Strategies for Glucose Control in Type 1 Diabetes The DREMED Trail- 2
NCT02776696
Advanced Hybrid Closed Loop System (AHCL) in Older Patients With Type 1 Diabetes Mellitus
NCT06236256
Feasibility Study to Evaluate the Hybrid-Logic Closed Loop System in Type 1 Diabetes
NCT02692547
Hybrid Closed Loop Pivotal Trial in Type 1 Diabetes
NCT02463097
An Open-label, Two-center, Randomized, Cross-over Study to Evaluate the Safety and Efficacy of Glycemic Control Using Hybrid-closed Loop vs. Advanced Hybrid Closed-loop in Young Subjects With Type 1 Diabetes
NCT04269668
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Several groups around the world investigate efforts in developing closed-loop systems. Investigators combined two closed-loop systems with different mode of operation in order to enhance the closed-loop system. The two systems are Hybrid closed-loop system and the MD-Logic closed-loop system . The combined algorithm Hybrid logic closed loop (HLCL) was tested 'In silico' and was proved to be safe and effective. The next step is to test the system in a clinical study in a supervised environment in a camp.
The two systems were tested separately in several clinical studies and were proven to be safe and effective in a diverse population of patients with type 1 diabetes. The MD-Logic system for overnight use "the GlucoSitter" has a CE mark.
The primary objective of the study is to characterize the overall management of the glycemic control using this system including Safety. The data collected in this study will be used to confirm/develop the HLCL System further.
Secondary objectives of this study include evaluation of the HLCL system in a monitored setting (camp) with the following stresses:Exercise, high carbohydrate and high fat meals
This study is a single-arm, single-center, in clinic Investigation in subjects with type 1 diabetes on insulin pump therapy.
Run-in Period:
A total of up to 10 subjects will be enrolled (age 18-40). A minimum of 6 days run-in period with sensor augmented pump will be used to collect sensors and insulin data and to allow the subject to become familiar.
Study Period - Camp:
Following the run-in period subjects will participate in a 5 day, 4 night study period in a camp setting during which the HLCL feature will be studied.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NA
SINGLE_GROUP
TREATMENT
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Closed Loop System
HLCL- Hybrid Logic Closed Loop System
All subjects wearing the HLCL System and using it with the closed loop algorithm
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
HLCL- Hybrid Logic Closed Loop System
All subjects wearing the HLCL System and using it with the closed loop algorithm
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Pump therapy for at least 6 months and Experience with sensor use
* Age 18-40
* A1C \<10.0 at time of screening visit
* Willing to follow study instructions
* Willing to perform ≥ 5 finger stick blood glucose measurements daily
* Willing to perform required sensor calibrations
* Patient capable of reading and understand instructions in English
Exclusion Criteria
* Subject has any unresolved adverse skin condition in the area of sensor or device placement (e.g., psoriasis, rash, Staphylococcus infection)
* Subject is actively participating in an investigational study (drug or device) wherein they have received treatment from an investigational study drug or device in the last 2 weeks
* Subject has a positive pregnancy screening test
* Subject is female, sexually active without the use of contraception, and plans/able to become pregnant during the course of the study and is not using an acceptable method of contraception
* Subject has had a hypoglycemic seizure within the past 5 months prior to screening visit
* Subject has had hypoglycemia resulting in loss of consciousness within the past 5 months prior to screening visit
* Subject has had an episode of diabetic ketoacidosis within the past 6 months prior to screening visit
* Subject has a history of a seizure disorder
* Subject has central nervous system or cardiac disorder resulting in syncope
* Subject has a history of myocardial infarction, unstable angina, coronary artery bypass surgery, coronary artery stenting, transient ischemic attack (TIA), cerebrovascular accident (CVA), angina, congestive heart failure, ventricular rhythm disturbances or thromboembolic disease
* Subjects with hematocrit lower than the normal reference range or local lab testing
* Subjects with a history or findings on screening electrocardiogram (EKG) of any cardiac arrhythmia, including atrial arrhythmias
* Subjects with a history of adrenal insufficiency
* Subjects with history of migraines that have occurred at least 2 times in the last 3 months prior to enrollment
* Any disease or condition that may influence the A1C testing e.g abnormal red blood cell indices and iron deficiency, sickle cell disease, hemoglobinopathy
18 Years
40 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Medtronic
INDUSTRY
Rabin Medical Center
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Moshe Phillip, MD, Prof
Role: PRINCIPAL_INVESTIGATOR
Rabin Medical Center
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Schneider Medical Center
Petah Tikva, , Israel
Countries
Review the countries where the study has at least one active or historical site.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
RMC076215ctil
Identifier Type: -
Identifier Source: org_study_id
More Related Trials