Non-invasive Quantification of Liver Iron With MRI

NCT ID: NCT02425956

Last Updated: 2017-07-24

Study Results

Results available

Outcome measurements, participant flow, baseline characteristics, and adverse events have been published for this study.

View full results

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Clinical Phase

NA

Total Enrollment

21 participants

Study Classification

INTERVENTIONAL

Study Start Date

2015-04-30

Study Completion Date

2016-06-30

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

This study is being conducted to build a library of prospectively collected clinical data from subjects with iron overload examined with commercially available MRI devices. This data library is intended for use in future engineering development and other research activities, including future regulatory submissions.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

This study is being conducted to build a library of prospectively collected clinical data from subjects with iron overload examined with commercially available MRI devices. This data library is intended for use in future engineering development and other research activities, including future regulatory submissions. Data from human subjects is required to develop and test Magnetic resonance (MR) reconstruction techniques that can provide quantitative information about tissue properties, such as volumetric fat and iron concentrations. Collection of MR data and corresponding quantitative liver iron concentration (LIC) data is necessary for development of MR techniques that can show both overall and regional iron concentrations of in vivo tissues. These techniques may provide viable alternatives to invasive and expensive conventional liver biopsy and to less accurate serum biomarker testing, potentially benefiting future clinical patients with iron overload.

MR image data and corresponding quantitative data about serum and liver iron levels will be collected from each subject in this study. These datasets are considered suitable for future development and testing of MR reconstruction software, including MR reconstruction algorithms developed by General Electric Healthcare (GEHC) to use Longitudinal relaxation rate equal to the reciprocal of T2 relaxation time (1/T2) (R2) techniques to assess LIC. To achieve a sufficiently diverse library for future testing, MRI data of the liver and surrounding tissues will be acquired using 1.5T and 3.0T GEHC IDEAL IQ scans and commercially available 1.5T MRI scans conducted according to the FerriScan® Specialized Reconstruction Service guidelines (Resonance Health, Claremont, AU). Quantitative hematologic (serum ferritin) based on blood testing and FerriScan® Analysis Service LIC reports will be collected for each subject.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Iron Overload

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

NA

Intervention Model

SINGLE_GROUP

Primary Study Purpose

DIAGNOSTIC

Blinding Strategy

NONE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

MRI imaging of liver

GE Optima/Discovery® MRI imaging data of the liver and surrounding tissues will be acquired using 1.5T and 3.0T GE Healthcare (GEHC) IDEAL IQ scans and commercially available 1.5T MRI scans conducted according to the FerriScan®

Group Type EXPERIMENTAL

GE Optima/Discovery® MRI data of the liver

Intervention Type DEVICE

GE Optima 1.5T®/Discovery 3.0T® MRI data scanning data of the liver and surrounding tissues will be acquired using both field strengths for GE IDEAL IQ® and single field strength with FerriScan® (Resondence Health) Specialized Reconstruction Service, according instructions provided by manufacturer

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

GE Optima/Discovery® MRI data of the liver

GE Optima 1.5T®/Discovery 3.0T® MRI data scanning data of the liver and surrounding tissues will be acquired using both field strengths for GE IDEAL IQ® and single field strength with FerriScan® (Resondence Health) Specialized Reconstruction Service, according instructions provided by manufacturer

Intervention Type DEVICE

Other Intervention Names

Discover alternative or legacy names that may be used to describe the listed interventions across different sources.

GE Optima/Discovery® MRI FerriScan® (Resondence Health) GE IDEAL IQ®

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

1. Be at least ten (10) years of age;
2. Have clinical history of iron overload;
3. If female of childbearing potential (not surgically sterile or post-menopausal), be determined non-pregnant by the medical co-investigator and/or a delegated physician on the study staff or are demonstrated non-pregnant by negative urine pregnancy test administered within the 24 hour period before participating in study procedures;
4. Provide evidence of willingness to participate by providing written informed consent to participate OR, if aged less than 18 years (\<18) be willing to provide written assent to participate and have parent(s) or legal guardian(s) willing to provide written informed consent for the subject's participation;
5. Be able to hear and understand instructions without assistive devices;
6. Have necessary mental capacity to understand instructions be able to comply with protocol requirements;
7. Be able to remain relatively motionless for the expected duration of imaging procedures (maximum of approximately 90 minutes).

Exclusion Criteria

1. Have medical history of present or prior focal liver disease, such as neoplasms or vascular abnormalities;
2. Have contraindication(s) to MRI scanning per the routine MR Safety Screening policy of the investigational site;
3. Are scheduled for surgery, changes in dosage or type of chelating medications, or other medical interventions in between blood draw and MRI scanning that could be expected to impact study results or conduct;
4. Have had or plan to have a change in dosage or type of chelating medications (such as Deferoxamine or Deferasirox) within the 3 days prior to the first study procedure (blood draw or MRI, whichever comes first);
5. Are minor subjects with parent(s) or legal guardian(s) that require that they accompany the subject into the MR environment;
6. Have previously participated in this study.
Minimum Eligible Age

10 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

GE Healthcare

INDUSTRY

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Responsibility Role SPONSOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Frank Korosec, PhD

Role: PRINCIPAL_INVESTIGATOR

University of Wisconsin, Madison

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

University of Wisconsin-Madison

Madison, Wisconsin, United States

Site Status

Countries

Review the countries where the study has at least one active or historical site.

United States

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

114-2014-GES-0039

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

Methods to Detect Liver Fibrosis
NCT03027700 TERMINATED NA
MRI to Measure Liver Fat Content
NCT00594412 COMPLETED NA
Identification of Hepatic Lesions
NCT00307866 COMPLETED PHASE3