Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
NA
12 participants
INTERVENTIONAL
2015-02-28
2018-12-31
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Comparison of Two Volar Plating Systems for Distal Radius Fractures
NCT03474445
Unstable Fractures of the Distal Radius: Trial of Volar Plate Versus Dorsal Nail Plate Fixation
NCT00848263
Conservative Treatment vs. Volar Plating of Distal Radius Fractures
NCT02990052
Intraarticular Distal Radius Fractures, X-fix or Volar Fixation
NCT01035359
Do Generic Volar Locking Plates Provide Similar Outcomes at a Reduced Cost?
NCT06343467
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Intramedullary fixation has recently received more attention in the literature because of the minimally invasive procedure required for device implantation. Additionally, because intramedullary fixation places the implant within the bone instead of onto it, the lack of implant exposure, as well as decreased soft tissue dissection, carries the potential for decreased inflammation at the surgical site. This prospective randomized case series will evaluate the clinical and functional outcomes of an expandable intramedullary fixation device and compare the complication profile with traditional fixed angle volar locked plating in a single-surgeon case series at a single hospital.
The wide variety of distal radius fractures demand customized treatment, and a number of different surgical treatments methods are available.(1) While percutaneous/external fixation, dorsal plating, fragment specific fixation, and intramedullary rod fixation have been studied, volar locked plate fixation has emerged over the past decade as the most common and versatile method of fracture fixation. Unfortunately, soft tissue and hardware complications continue to plague volar plate fixation, including digital stiffness, loss of forearm rotation, tendinopathy and tendon rupture, nerve injury and compression, hardware irritation, screw prominence, CRPS, and malunion.
Tarallo et al performed a retrospective review of 303 patients who had undergone volar plate fixation and found that implant-related complications had occurred in 5% of the patients (2). Of these, common complications seen were tendon rupture, screw loosening, and penetration into the articular space. While Tarallo et al studied only hardware related complications, other studies have reported complications associated of volar locking plate fixation as high as 22-27% (3,4). The flexor pollicis longus in particular is vulnerable to rupture, as hardware prominence at the watershed line of the distal radius exposes the FPL and other flexor tendons to frictional forces which result in fraying and rupture (5). Prominent pegs or screws dorsally threaten the extensor pollicis longus and neighboring extensor tendons.
Intramedullary fixation has limited data to date, and the current methods are applicable to a relatively narrow subset of radial fracture types. In a case series of three patients, Gunther and Lynch have shown that intramedullary fixation performed with a partially flexible rod that can be locked into rigid position once implanted in the bone resulted in good functional outcomes (6). Patients returned to their daily lives and at one-year post-operatively no adverse effects were reported. A prospective study analyzing the comparative functional outcomes between intramedullary nail versus volar plate fixation similarly found that functional recovery was comparative between the two groups, and that complication rates were slightly lower in the intramedullary fixation cohort (7). The authors of this study however noted the continued potential for screw penetration into the distal radioulnar joint (DRUJ).
The Conventus DRS expandable intramedullary fixation device used in this proposed study is FDA approved. A cadaveric study compared the fixation strength of the Conventus DRS with fixed angle volar plate fixation and demonstrated equivalency between the two for axial compression mean stiffness and dorsal bend mean stiffness (8). The Conventus DRS has been used in Europe where over 250 patients have been treated with the device. A safety and efficacy 'white paper' of the first 60 patients treated for a wide variety of fractures demonstrated excellent improvements in DASH scores with few hardware related events and an overall adverse event profile of 8.3%. (9) There was one re-operation for loss of fixation and four minor cases of neuritis that resolved. The device is FDA-approved in the US, and is being used across the country.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
RANDOMIZED
PARALLEL
TREATMENT
SINGLE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Volar Plate
Patients in this group will undergo distal radius fracture fixation with a traditional volar plate.
Volar Plate
A volar plate is a metallic plate fastened directly to the fractured bone with screws, to hold the fracture fragments in proper position. Volar plate fixation is the traditional surgical method for distal radius fractures.
Conventus DRS
Patients in this group will undergo distal radius fracture fixation with the Conventus DRS intramedullary fixation device.
Conventus DRS
The Conventus DRS (TM) is an intramedullary device intended to treat distal radius fractures. The device remains flexible during placement, but is made rigid at the completion of the surgical implant procedure. The implant is made from titanium alloy (Ti-6A1-4V) and Nitinol.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Conventus DRS
The Conventus DRS (TM) is an intramedullary device intended to treat distal radius fractures. The device remains flexible during placement, but is made rigid at the completion of the surgical implant procedure. The implant is made from titanium alloy (Ti-6A1-4V) and Nitinol.
Volar Plate
A volar plate is a metallic plate fastened directly to the fractured bone with screws, to hold the fracture fragments in proper position. Volar plate fixation is the traditional surgical method for distal radius fractures.
Other Intervention Names
Discover alternative or legacy names that may be used to describe the listed interventions across different sources.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Unstable AO Type A and C1 fractures
* Closed injuries, acute (\<14 days), displaced, and unstable
Exclusion Criteria
* Patients with documented complex regional pain syndrome (CRPS) or history of CRPS
* Patients with suspected or known allergies to titanium or nickel
* Patients who are non-English speakers
* Patients with open wound fractures
* Patients with inflammatory arthritis
* Patients with positive pregnancy test
* Previous major wrist injury or surgery (not including Carpal Tunnel, De Quervain's and trigger finger release)
* Patients with previously diagnosed metabolic bone disease, currently being treated.
* Non-English speaking patients (validated, translated questionnaires are not available)
* Patients needing ipsilateral concomitant operations that will have material impact on the study
* Patients with previous wrist fractures, prior wrist injury, stiffness, degenerative joint disease, or pain
18 Years
85 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Conventus Orthopaedics, Inc.
INDUSTRY
Hospital for Special Surgery, New York
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Scott W Wolfe, MD
Role: PRINCIPAL_INVESTIGATOR
Hospital for Special Surgery, New York
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Hospital for Special Surgery
New York, New York, United States
Countries
Review the countries where the study has at least one active or historical site.
References
Explore related publications, articles, or registry entries linked to this study.
Tarallo L, Mugnai R, Zambianchi F, Adani R, Catani F. Volar plate fixation for the treatment of distal radius fractures: analysis of adverse events. J Orthop Trauma. 2013 Dec;27(12):740-5. doi: 10.1097/BOT.0b013e3182913fc5.
Rozental TD, Blazar PE. Functional outcome and complications after volar plating for dorsally displaced, unstable fractures of the distal radius. J Hand Surg Am. 2006 Mar;31(3):359-65. doi: 10.1016/j.jhsa.2005.10.010.
Arora R, Lutz M, Hennerbichler A, Krappinger D, Espen D, Gabl M. Complications following internal fixation of unstable distal radius fracture with a palmar locking-plate. J Orthop Trauma. 2007 May;21(5):316-22. doi: 10.1097/BOT.0b013e318059b993.
Limthongthang R, Bachoura A, Jacoby SM, Osterman AL. Distal radius volar locking plate design and associated vulnerability of the flexor pollicis longus. J Hand Surg Am. 2014 May;39(5):852-60. doi: 10.1016/j.jhsa.2014.01.038. Epub 2014 Mar 14.
Gunther SB, Lynch TL. Rigid internal fixation of displaced distal radius fractures. Orthopedics. 2014 Jan;37(1):e34-8. doi: 10.3928/01477447-20131219-14.
Gradl G, Mielsch N, Wendt M, Falk S, Mittlmeier T, Gierer P, Gradl G. Intramedullary nail versus volar plate fixation of extra-articular distal radius fractures. Two year results of a prospective randomized trial. Injury. 2014 Jan;45 Suppl 1:S3-8. doi: 10.1016/j.injury.2013.10.045. Epub 2013 Nov 4.
van Kampen RJ, Thoreson AR, Knutson NJ, Hale JE, Moran SL. Comparison of a new intramedullary scaffold to volar plating for treatment of distal radius fractures. J Orthop Trauma. 2013 Sep;27(9):535-41. doi: 10.1097/BOT.0b013e3182793df7.
Palmer AK, Hale JE. Conventus DRS Plating System: A Preliminary Report [White paper]. Conventus Orthopedics 2013. Retrieved from <http://www.conventusortho.com/wp-content/uploads/2015/03/4473-1-Rev-2-White-Paper-Conventus-Distal-Radius-System-A-Preliminary-Report.pdf>.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
2014-211
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.