Phase 2 Study of Adaptive Insulin Meal Supervisor (AIMS) in Adults With Type 1 Diabetes Mellitus
NCT ID: NCT01839370
Last Updated: 2014-02-19
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
NA
9 participants
INTERVENTIONAL
2013-07-31
2013-11-30
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Effect of Basal-Bolus Closed-Loop Co-Administration of Insulin and Pramlintide on Improving the Glycemic Control in Type 1 Diabetes
NCT02814123
The Effect of Pramlintide on Meal Time Insulin Bolus
NCT00460304
Co-administration of Pramlintide and Insulin Via an Automated Dual-hormone Artificial Pancreas System in Adults With Type 1 Diabetes
NCT04243629
Insulin-plus-pramlintide Closed-loop Strategy to Regulate Glucose Levels Without Carbohydrate Counting
NCT03800875
Use of Control-IQ Technology 2.0 in Adults, Children, and Preschoolers With Type 1 Diabetes
NCT05683392
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
RANDOMIZED
CROSSOVER
TREATMENT
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Closed Loop with Pramlintide
The experimental condition consists of closed loop admission with the Adaptive Insulin Meal Supervisor system (AIMS) system with pramlintide 30 mcg at meal time. During this admission, the Diabetes Assistant (DiAs), a Cell Phone Medical Platform and the central component of the system, will provide basal insulin to maintain glucose levels within a prescribed range.
Closed Loop with Pramlintide
A closed-loop automated insulin management system (Adaptive Insulin Meal Supervisor- AIMS) for meals utilizing continuous glucose monitoring (CGM)and subcutaneous insulin pump and a standard pramlintide therapy will be compared to a standard pramlintide therapy alone to control glucose levels in individuals with type 1 diabetes. DiAs is controlled by the subject, with assistance from the study personnel as needed.
Open Loop with Pramlintide
Insulin delivery will be controlled by the DiAs system running in Open Loop mode. Subjects will be permitted to administer correction boluses and set temporary temporary basal levels at any time during the admission, whether or not they are eating a scheduled meal. Subjects will inject Pramlintide 30 mcg prior to meal time.
No interventions assigned to this group
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Closed Loop with Pramlintide
A closed-loop automated insulin management system (Adaptive Insulin Meal Supervisor- AIMS) for meals utilizing continuous glucose monitoring (CGM)and subcutaneous insulin pump and a standard pramlintide therapy will be compared to a standard pramlintide therapy alone to control glucose levels in individuals with type 1 diabetes. DiAs is controlled by the subject, with assistance from the study personnel as needed.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
2. Clinical diagnosis of type 1 diabetes mellitus. For an individual to be enrolled at least one criterion from each list must be met.
o Criteria for documented hyperglycemia (at least 1 must be met): i. Fasting glucose ≥126 mg/dL - confirmed ii. Two-hour Oral Glucose Tolerance Test (OGTT) glucose ≥200 mg/dL - confirmed iii. HbA1c ≥6.5% documented - confirmed iv. Random glucose ≥200 mg/dL with symptoms v. No data at diagnosis is available but the participant has a convincing history of hyperglycemia consistent with diabetes
o Criteria for requiring insulin at diagnosis (1 must be met): i. Participant required insulin at diagnosis and continually thereafter ii. Participant did not start insulin at diagnosis but upon investigator review likely needed insulin (significant hyperglycemia that did not respond to oral agents) and did require insulin eventually and used continually iii. Participant did not start insulin at diagnosis but continued to be hyperglycemic, had positive islet cell antibodies - consistent with latent autoimmune diabetes in adults (LADA) and did require insulin eventually and used continually
3. Use of an insulin pump to treat his/her diabetes for at least 1 year.
4. Familiarity with a bolus calculator with the current insulin pump with pre-defined parameters for carbohydrate (CHO) ratio, insulin sensitivity factor (ISF), target glucose and active insulin.
5. HbA1c 6.5-9% as measured with DCA2000 or equivalent device.
6. Not currently known to be pregnant, breast feeding, or intending to become pregnant (females).
7. Demonstration of proper mental status and cognition for the study.
8. Willingness to avoid consumption of acetaminophen-containing products during the study interventions involving CGM use.
9. Willingness to refrain from strenuous exercise for 2 days prior to admission. Non-strenuous walks of less than 15 minutes around the guest house will be permitted during the study.
10. If on antihypertensive, thyroid, anti-depressant or lipid lowering medication, have stability on the medication for at least 2 months prior to enrollment in the study.
11. Normal renal function (determined utilizing the comprehensive metabolic panel at screening with the Modification of Diet in Renal Disease (MDRD) formula and defined by estimated Glomerular Filtration Rate (eGFR) ≥60 ml/min/1.73 m2.
Exclusion Criteria
2. Severe hypoglycemia resulting in seizure, loss of consciousness, or diabetic ketoacidosis (DKA) within the 12 months prior to enrollment.
3. Pregnancy; breast feeding, or intention of becoming pregnant.
4. Uncontrolled arterial hypertension (Resting diastolic blood pressure \>90 mmHg and/or systolic blood pressure \>160 mmHg).
5. Conditions which may increase the risks associated with possible hypoglycemia, such as any active cardiac disorder/arrhythmia, uncontrolled coronary artery disease during the previous year (e.g. history of myocardial infarction, acute coronary syndrome, therapeutic coronary intervention, coronary bypass or stenting procedure, stable or unstable angina, episode of chest pain of cardiac etiology with documented electrocardiogram (EKG) changes, or positive stress test or catheterization with coronary blockages \>50%), congestive heart failure, history of cerebrovascular event, seizure disorder, syncope, adrenal insufficiency, neurologic disease or atrial fibrillation.
6. Self-reported hypoglycemia unawareness.
7. History of a systemic or deep tissue infection with methicillin-resistant staph aureus or Candida albicans.
8. Use of a device that may pose electromagnetic compatibility issues and/or radiofrequency interference with the CGM (implantable cardioverter-defibrillator, electronic pacemaker, neurostimulator, intrathecal pump, and cochlear implants).
9. Anticoagulant therapy other than aspirin.
10. Medical condition requiring use of an acetaminophen-containing medication that cannot be withheld for the study admissions.
11. Psychiatric disorders that would interfere with study tasks (e.g. inpatient psychiatric treatment within 6 months prior to enrollment).
12. Mental incapacity, unwillingness or language barriers precluding adequate understanding or cooperation.
13. Known current or recent alcohol or drug abuse.
14. Medical conditions that would make operating a CGM, the DiAs cell phone or insulin pump difficult (e.g. blindness, severe arthritis, immobility).
15. Any skin condition that prevents sensor or pump placement on the abdomen or arm (e.g. bad sunburn, pre-existing dermatitis, intertrigo, psoriasis, extensive scarring, cellulitis).
16. In adherence with the One Touch Ultra 2 User Guide, subjects with hematocrit levels less than 30% and above 55% will be excluded.
17. Impaired hepatic function measured as alanine aminotransferase or aspartate aminotransferase ≥three times the upper reference limit.
18. Abnormal liver function (Transaminase \>2 times the upper limit of normal).
19. Uncontrolled microvascular (diabetic) complications, such as current proliferative diabetic retinopathy or macular edema, known diabetic nephropathy (other than microalbuminuria with normal creatinine) or neuropathy requiring drug treatment.
20. Active gastroparesis requiring current medical therapy.
21. Uncontrolled adrenal disorder.
22. Uncontrolled thyroid disease.
23. If on antihypertensive, thyroid, anti-depressant or lipid lowering medication, lack of stability on the medication for the past 2 months prior to enrollment in the study.
24. Known bleeding diathesis or dyscrasia.
25. Known allergy to medical adhesives, components of the insulin pump insertion set or continuous glucose monitor sensor.
26. Subjects with basal rates less than 0.01U/hr.
27. Subjects who are sexually active and able to become pregnant and not using an acceptable method of birth control.
RESTRICTIONS ON USE OF OTHER DRUGS OR TREATMENTS
1. Use of anti-diabetic agents other than continuous subcutaneous insulin infusion (CSII) including long-acting insulin, intermediate-acting insulin, metformin, sulfonylureas, meglitinides, thiazolidinediones, dipeptidyl peptidase 4 (DPP-4 ) inhibitors, glucagon- like peptide 1 agonists, colesevelam, quick release bromocriptine, sodium-glucose linked transporter (SGLT-2) inhibitors and alpha-glucosidase inhibitors.
2. Acetaminophen will not be allowed while the continuous glucose monitor is in use.
3. Medications that block symptoms of hypoglycemia, including but not limited to beta blockers.
4. Oral steroids or other medications, which in the judgment of the investigator would be a contraindication to participation in the study.
5. Use of drugs that stimulate gastrointestinal motility (e.g. metoclopramide).
6. Orally administered medications (prescription and non-prescription) which require rapid onset as a critical determinant of effectiveness must be given at least 1 hour prior to or 2 hours after the Pramlintide injection and that subjects who require such medications be excluded if the medication must be given less than 1 hour prior to or 2 hours after the pramlintide dose.
7. Medications known to interfere with hypoglycemic symptoms including but not limited to beta- blockers, clonidine, reserpine, and guanethidine.
21 Years
65 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
DexCom, Inc.
INDUSTRY
Tandem Diabetes Care, Inc.
INDUSTRY
University of Virginia
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Anthony McCall
James M. Moss Professor of Diabetes in Internal Medicine
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Anthony McCall, MD, PhD
Role: PRINCIPAL_INVESTIGATOR
University of Virginia
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
University of Virginia
Charlottesville, Virginia, United States
Countries
Review the countries where the study has at least one active or historical site.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
16666
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.