Use of Control-IQ Technology 2.0 in Adults, Children, and Preschoolers With Type 1 Diabetes

NCT ID: NCT05683392

Last Updated: 2024-12-20

Study Results

Results available

Outcome measurements, participant flow, baseline characteristics, and adverse events have been published for this study.

View full results

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Clinical Phase

NA

Total Enrollment

72 participants

Study Classification

INTERVENTIONAL

Study Start Date

2023-02-01

Study Completion Date

2023-12-13

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

The goal of this clinical trial is to assess safety of and explore glycemic outcomes with Control-IQ technology 2.0 in adults, children and preschoolers with type 1 diabetes.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

This feasibility study is a prospective, randomized, two-period crossover multi-center study of Control-IQ technology 2.0. After a two week run-in period, the automated insulin dosing (AID) system will be evaluated in multiple age groups over 4 weeks of use.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Type 1 Diabetes

Keywords

Explore important study keywords that can help with search, categorization, and topic discovery.

Control-IQ technology type 1 diabetes

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

RANDOMIZED

Intervention Model

CROSSOVER

Primary Study Purpose

TREATMENT

Blinding Strategy

NONE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Control-IQ 2.0 Lower Range First, then Standard Range

After a two week run in period with Control-IQ 1.5, participants will use t:slim X2 pump with Control-IQ technology 2.0 with a lower range for two weeks, followed by use of t:slim X2 pump with Control-IQ technology 2.0 with a standard range for two weeks.

Group Type EXPERIMENTAL

t:slim X2 insulin pump with Control-IQ technology 2.0

Intervention Type DEVICE

t:slim X2 insulin pump with Control-IQ technology 2.0, and wearing the Dexcom G6 sensor.

Control-IQ 2.0 Standard Range First, then Lower Range

After a two week run in period with Control-IQ 1.5, participants will use t:slim X2 pump with Control-IQ technology 2.0 with a standard range for two weeks, followed by use of t:slim X2 pump with Control-IQ technology 2.0 with a lower range for two weeks.

Group Type EXPERIMENTAL

t:slim X2 insulin pump with Control-IQ technology 2.0

Intervention Type DEVICE

t:slim X2 insulin pump with Control-IQ technology 2.0, and wearing the Dexcom G6 sensor.

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

t:slim X2 insulin pump with Control-IQ technology 2.0

t:slim X2 insulin pump with Control-IQ technology 2.0, and wearing the Dexcom G6 sensor.

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Age 2 to ≤ 81 years
* Diagnosis of type 1 diabetes for at least 1 year, or at least 6 months for age 2-5 years at enrollment
* Prior Dexcom CGM user, with at least 11 of the prior 14 days of CGM use available for download at the screening visit to confirm eligibility
* Total Daily Insulin Dose (TDD) at least 2 units/day
* Weight ≥ 20 lbs
* HbA1c ≤ 10.5%
* For participants \<18 years old, living with one or more parent/legal guardian knowledgeable about emergency procedures for severe hypoglycemia, present with the participant during and after the meal challenges, and willing to use the Dexcom Follow app (with push notifications turned on) for the duration of the study.
* For participants ≥18 years old, availability of a local contact who has access to the study participant, and willing to use the Dexcom Follow app (with push notifications turned on) for the duration of the study. If the participant lives alone, the local contact must live within 30 minutes and have access to the subject overnight.
* Investigator has confidence that the participant and/or parent/guardian can successfully operate all study devices and is capable of adhering to the protocol.
* Willing to use only aspart (novolog) or lispro (humalog) insulin with the study devices, with no use of long-acting basal insulin injections, or inhaled insulin with the study devices.
* Have current glucagon product to treat severe hypoglycemia (injectable or nasal) at home (site will provide prescription if they do not have one)
* Willing and able to perform study meal challenges.

Exclusion Criteria

* More than 1 episode of diabetic ketoacidosis (DKA) in the past 6 months
* More than 1 episode of severe hypoglycemia (needing assistance) in the past 6 months
* Inpatient psychiatric treatment in the past 6 months
* For Female: Currently pregnant or planning to become pregnant during the time period of study participation

1. A negative pregnancy test will be required for all females of child-bearing potential
2. Counseling on appropriate birth control options will be provided to all females of child-bearing potential
* Concurrent use of any non-insulin glucose-lowering agent, other than metformin (for example, GLP-1 agonists, Symlin, DPP-4 inhibitors, SGLT-2 inhibitors, sulfonylureas).
* Hemophilia or any other bleeding disorder
* Hemoglobinopathy
* History of heart, liver, lung or kidney disease determined by investigator to interfere with the study
* History of allergic reaction to Humalog or Novolog
* Use of any medications determined by investigator to interfere with study
* Significant chronic kidney disease (which could impact CGM accuracy in investigator's judgment) or hemodialysis
* Concurrent use of any medication that could interfere with the study CGM, such as hydroxyurea
* History of adrenal insufficiency
* History of abnormal TSH consistent with hypothyroidism or hyperthyroidism that is not appropriately treated
* History of gastroparesis
* A condition, which in the opinion of the investigator or designee, would put the participant or study at risk
* Participation in another pharmaceutical or device trial at the time of enrollment or anticipated for during the time period of study participation
* Employed by, or having immediate family members employed by Tandem Diabetes Care, Inc., or having a direct supervisor at place of employment who is also directly involved in conducting the clinical trial (as a study investigator, coordinator, etc.); or having a first-degree relative who is directly involved in conducting the clinical trial
Minimum Eligible Age

2 Years

Maximum Eligible Age

80 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Tandem Diabetes Care, Inc.

INDUSTRY

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Responsibility Role SPONSOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Jordan Pinsker, MD

Role: STUDY_DIRECTOR

Tandem Diabetes Care, Inc.

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Barbara Davis Center (Pediatric Clinic)

Aurora, Colorado, United States

Site Status

Barbara Davis Center

Aurora, Colorado, United States

Site Status

Joslin Diabetes Center

Boston, Massachusetts, United States

Site Status

University of Virginia

Charlottesville, Virginia, United States

Site Status

Countries

Review the countries where the study has at least one active or historical site.

United States

References

Explore related publications, articles, or registry entries linked to this study.

Brown SA, Laffel LM, Akturk HK, Forlenza GP, Shah VN, Wadwa RP, Cobry EC, Isganaitis E, Schoelwer M, Lu VS, Rueda R, Sherer N, Corbett JP, Sasson-Katchalski R, Pinsker JE. Randomized, Crossover Trial of Control-IQ Technology with a Lower Treatment Range and a Modified Meal Bolus Module in Adults, Adolescents, Children, and Preschoolers with Varying Levels of Baseline Glycemic Control. Diabetes Technol Ther. 2025 Mar;27(3):187-193. doi: 10.1089/dia.2024.0501. Epub 2024 Nov 26.

Reference Type RESULT
PMID: 39601043 (View on PubMed)

Provided Documents

Download supplemental materials such as informed consent forms, study protocols, or participant manuals.

Document Type: Study Protocol and Statistical Analysis Plan

View Document

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

TP-0011713

Identifier Type: -

Identifier Source: org_study_id