Comparison of RightSpot pH Indicator & RightLevel pH Detector With X-Ray Verification for FT or G-Tube Placement

NCT ID: NCT01825564

Last Updated: 2017-01-24

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

TERMINATED

Total Enrollment

11 participants

Study Classification

OBSERVATIONAL

Study Start Date

2013-03-14

Study Completion Date

2016-05-25

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

Replacing a G tube and placing feeding tubes is standard in the Emergency Department (ED) and ICU, respectively. However placement requires a chest or abdominal x-ray to confirm correct position. The investigators are testing the accuracy of the FDA approved devices RightSpot pH Indicator \& RightLevel pH Detector in determining correct position based upon pH which will then be correlated with the standard of care x-ray.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Feeding tube placement is a common procedure that occurs in most ICU healthcare settings. In addition, replacement of G-tubes is a common practice in most ED settings throughout the US. Various practices have been used to confirm its placement, including the usage of litmus paper (acid versus base only), pH level indicators (precise measurement), auscultation, bubbling method, aspirate appearance, chest radiography (CXR) and gastrografin .

Review of data in numerous studies has revealed that many of these techniques may not provide fully accurate results, possibly leading to the potential for patient injuries, and even fatal complications. Auscultation, bubbling method, and aspirate appearance have been demonstrated to provide findings that can be misinterpreted and cause false assurance of correct placement. Several deaths and serious injuries have been attributed to the use of litmus paper in verification of feeding tube placement and subsequent utilization of the tube as well as G-tube replacement. Consequently, litmus paper is no longer considered to be a safe and effective confirmatory test for feeding tube placement or G-tube replacement.

Currently, the gold standard for verification of feeding tube placement is CXR or abdominal x-ray and G-tube replacement in an acute care setting is abdominal x-ray with gastrografin. This method is time-consuming, costly, and results in an increase in patient exposure to radiation. In addition for a patient who resides outside of the hospital setting at the time of needed G-tube replacement there is additional costs of transport to and from the ED. An alternative to CXR is measurement of gastric content pH level. This is a confirmed and valid tool for nasogastric/orogastric (NG/OG) verification and a recognized replacement of the litmus paper test.A pH level of 4.5 or less has been validated to indicate presence of gastric contents. A drawback to the use of typical pH indicators alone is that they require fluid aspirate to be placed manually onto the indicator surface. This increases the risk of exposure to bodily fluids for medical personnel. Thus, the ideal device to determine accurate feeding tube placement and G-tube replacement is one that will precisely measure the acid (pH) level of aspirate and significantly reduce the risk of bodily fluid exposure.

The RightSpot pH Indicator \& RightLevel pH Detector are devices which purport to meet both of these criteria. Both can provide an accurate pH level. The pH paper is encased in a protective exterior that can be attached directly to a syringe, thus, decreasing the likelihood of accidental exposure.

This study will evaluate the use of this novel device to accurately verify feeding tube placement in an ICU care setting and G-tube replacement (of foley catheter) by measuring the pH and comparing this with gastrografin radiographic confirmation.

The G-tube (or foley catheter) will be placed by the treating physician, resident, mid-level provider or nurse as per policy and standard of care in the ICU or Emergency Department. Prior to x-ray confirmation of placement with gastrografin, the RightBio Metrics device will be placed on the tube as per manufacturer's instructions and stomach contents aspirated. The reading of the pH indicator and time it took to measure the pH will be recorded. The device will then be removed. Tube placement verification by x-ray will be done as per hospital protocol. The time of radiology reading of the x-ray will be documented.

Procedures for feeding tube are similar, however two pH measurements will be obtained. The first measurement will be obtained with RightSpot pH Indicator at the time the tube is inserted into the stomach to measure gastric pH, and the second pH measurement will be obtained one hour later with RightLevel pH Detector to assess whether or not a pH change has occurred that suggests the tube has migrated into the small bowel. Radiographic confirmation will also be obtained at that time as it is the standard of care for feeding tube placements at SLU Hospital.

Relevant aspects of subject's prior history will be recorded on a standardized data collection form (DCF). These include:

* Demographics
* Surgical history - when the G-tube was placed
* Current medications
* Any previous gastric bypass surgery or other GI surgery
* Use of acid-reducing medications in the past week (e.g. antacids, proton pump inhibitors, histamine antagonists)
* Relevant medical history (e.g. gastric ulcer, achlorhydria)
* Cost related information such as ambulance cost to and from ED, cost of x-ray for G-tube (or foley) replacement, cost of radiographic interpretation

As this is a minimal risk device and the main endpoint is whether or not the device could determine placement of a feeding tube or G-tube, patients will not be followed beyond 24 hours.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Gastrostomy

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Observational Model Type

COHORT

Study Time Perspective

PROSPECTIVE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Age older than 18
* Requirement for placement of a feeding tube or a G-tube replacement
* Patient or proxy able to provide informed consent
* English proficiency of person providing informed consent

Exclusion Criteria

* Patients that are younger than the age of 18
* Inability to obtain consent
* Grossly bloody aspirate
* Pregnancy
Minimum Eligible Age

18 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

St. Louis University

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Timothy Havens, MD

Assistant Professor

Responsibility Role PRINCIPAL_INVESTIGATOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Timothy Havens, MD

Role: PRINCIPAL_INVESTIGATOR

St. Louis University

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Saint Louis University Hospital

St Louis, Missouri, United States

Site Status

Countries

Review the countries where the study has at least one active or historical site.

United States

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

EZNG-SLU-450126, 22201

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.