Efficacy Between Different Two Self-Expanding Nitinol Stents For The Atherosclerotic Femoro-Popliteal Arterial Disease
NCT ID: NCT01570803
Last Updated: 2018-03-15
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
WITHDRAWN
NA
INTERVENTIONAL
2013-01-31
2018-01-31
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Study of Drug Eluting Peripheral Vascular Stent System in Superficial Femoral Artery Stenosis and /or Occlusion
NCT03121430
Outcomes of Femoro-popliteal Disease After Stent Deployment Under Intravascular Ultrasound Guidance
NCT02037113
Fatigue Behavior of Peripheral STENt of the Superficial Femoral Artery
NCT06198920
Vessel Deformations and Restenosis After Stenting of the Popliteal Artery
NCT04700371
Efficacy of Subintimal vs Intraluminal Approach for Atherosclerotic Chronic Occlusive Femoropopliteal Arterial Disease
NCT02544555
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
The design of self-expandible nitinol stents might be different depending on the developed time; The first-generation nitinol stents (e.g., LuminexxTM and SmartTM) showed a remarkably high rate of stent strut fracture. A second generation of slotted tube nitinol stents has been developed. These stents had a better flexibility, by reducing the number of connections between cells or crowns, and by configurating spiral orientation of these interconnections. Several studies reported that these nitinol stents are more fracture-resistant and more flexible, some of them providing superior patency rate (e.g., LifeTM and EverflexTM). However, the one of the important limitations to their studies is that those was the non-randomized study of relative small sample size or was confined to in-vitro. Upto date, the multicenter, randomized controlled trial for direct comparison of stent fracture and primary patency between two different nitinol stents has not been done except one study; SMART versus Luminexx stent. SMART and Luminexx stent have been classified into 1st generation self-expandable nitinol stent. Complete-SE stent of Medtronic company was different to Smart stent of Cordis company in that the configuration of interconnection of Complete-SE stent had peak-to-peak connection and more spiral orientation of interconnection, compared to mart stent. On the other hand, Smart stent has the peak-to-valley bridge and in-line interconnection. Medtronics company have claimed Complete's stent crowns have been configured to minimize crown to crown interaction, increasing the stent's flexibility without compromising radial strength. We made the hypothesis that the design of Complete-SE stent might be more fracture-resistant or effective for in-stent restenosis, compared with Smart stent.
On the other hand, to date, in previous many reports, the dual antiplatelet therapy consisted of aspirin and clopidogrel have proven to decrease the incidence of cardiovascular death, myocardial infarction, or revascularization without an increase in major bleeding in patients who underwent percutaneous coronary intervention regardless of stent type (bare metal stent or drug-eluting stent). In 2011 ESC (European society of cardiology) guideline, dual antiplatelet therapy with aspirin and a thienopyridine for at least one month is recommended after infra-inguinal bare metal stent implantation (Class I, Level C). However, there have been no the definite evidence or guideline for the optimal antiplatelet agents after stent implantation one month later. There have been many studies for the efficacy of thienopyridine in peripheral arterial disease. Also, With the potential benefit of cilostazol on vascular function in vitro, there have several previous efforts to prove the efficacy of cilostazol in patients undergoing endovascular therapy or stent implantation in peripheral arterial disease. However, still specific data regarding a variety of antiplatelet regimen are limited. Also, very few trials have effectively nor properly addressed the direct comparison for the efficacy and safety between clopidogrel and cilostazol. This trial designed to evaluate the efficacy and safety between aspirin plus clopidogrel versus aspirin plus cilostazol in patients undergoing stent implantation in femoropopliteal lesions.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
RANDOMIZED
PARALLEL
TREATMENT
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Complete SE Stent
study design is 2x2 randomization design. First, before randomization, stratification will be performed according to lesion length 15cm criteria at web-based computerized program. Patients will be randomized in a 1:1 manner according to different two (SMART versus Complete-SE) stents. And then, patients received aspirin and clopidogrel during one month. After one month from index procedure, patients were randomized to receive either clopidogrel group (clopidogrel will not be changed but continue) or cilostazol group (clopidogrel will be changed into cilostazol) in separate groups of SMART group and Complete SE group. Randomization procedure will be performed using a web-based program
Complete SE Stent
same to SMART CONTROL Stent
SMART CONTROL Stent
same to Complete SE
S.M.A.R.T CONTROL Stent
Provisional stenting should be performed; the case that optimal ballooning response is not obtained (sub-optimal balloon response) should be enrolled. The procedure is usually done, as follows; After the guidewire is passed through the target lesion, predilation of the target lesion with an optimally sized balloon will be performed prior to stent implantation. Recommended, minimal balloon dilation time is 120 seconds. The sub-optimal balloon response is defined as a residual pressure gradient of \>15 mmHg, residual stenosis of \>30%, and flow-limiting dissection.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
S.M.A.R.T CONTROL Stent
Provisional stenting should be performed; the case that optimal ballooning response is not obtained (sub-optimal balloon response) should be enrolled. The procedure is usually done, as follows; After the guidewire is passed through the target lesion, predilation of the target lesion with an optimally sized balloon will be performed prior to stent implantation. Recommended, minimal balloon dilation time is 120 seconds. The sub-optimal balloon response is defined as a residual pressure gradient of \>15 mmHg, residual stenosis of \>30%, and flow-limiting dissection.
Complete SE Stent
same to SMART CONTROL Stent
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
1. Age 20 years of older
2. Symptomatic peripheral-artery disease with (Rutherford 2 - 6); moderate to severe claudication (Rutherford 2-3), chronic critical limb ischemia with pain while was at rest (Rutherford 4), or with ischemic ulcers (Rutherford 5-6)
3. Patients with signed informed consent
* Anatomical criteria
1. Stenosis of \>50% or occlusive atherosclerotic lesion of the ipsilateral femoropopliteal artery
2. Patent (≤50% stenosis) ipsilateral iliac artery or concomitantly treatable ipsilateral iliac lesions (≤30% residual stenosis),
3. At least one patent (less than 50% stenosed) tibioperoneal run-off vessel.
Exclusion Criteria
2. Major bleeding history within prior 2 months
3. Known hypersensitivity or contraindication to any of the following medication: heparin, aspirin, clopidogrel, cilostazol, or contrast agent
4. Acute limb ischemia
5. Previous bypass surgery or stenting of the ipsilateral femoropopliteal artery
6. Untreated inflow disease of the ipsilateral pelvic arteries (more than 50% stenosis or occlusion)
7. Patients that major amputation ("above the ankle" amputation) has been done, is planned or required
8. Patients with life expectancy \<1 year due to comorbidity
20 Years
90 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Korea University Guro Hospital
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Seung Woon Rha
Clinical Professor
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Seung-Woon Rha, MD, PhD
Role: PRINCIPAL_INVESTIGATOR
Cardiovascular Center, Korea University Guro Hospital, 80, Guro-dong, Guro-gu, Seoul, 152-703, Korea
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Cardiovascular center, Korea University Guro Hospital
Seoul, , South Korea
Korea University Guro Hospital
Seoul, , South Korea
Countries
Review the countries where the study has at least one active or historical site.
References
Explore related publications, articles, or registry entries linked to this study.
Park SH, Rha SW, Choi CU, Kim EJ, Oh DJ, Cho YH, Choi WG, Lee SJ, Kim YH, Choi SH, Kim WH, Kim KC, Cho JH, Kim JH, Kim SM, Bae JH, Bong JM, Kang WY, Baek JY, Seo JB, Chung WY, Park MW, Her SH, Suh J, Kim MW, Kim YJ, Choi HJ, Soh JW; SENS-FP Investigators. Efficacy of two different self-expanding nitinol stents for atherosclerotic femoropopliteal arterial disease (SENS-FP trial): study protocol for a randomized controlled trial. Trials. 2014 Sep 10;15:355. doi: 10.1186/1745-6215-15-355.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
SENS-FP
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.