Efficacy Between Different Two Self-Expanding Nitinol Stents For The Atherosclerotic Femoro-Popliteal Arterial Disease

NCT ID: NCT01570803

Last Updated: 2018-03-15

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

WITHDRAWN

Clinical Phase

NA

Study Classification

INTERVENTIONAL

Study Start Date

2013-01-31

Study Completion Date

2018-01-31

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

Recent stent design improvements focus on decreasing stent fracture rates which can negatively impact patency rates by rearranging strut alignment. Although there have been several retrospective or registry studies for atherosclerotic femoropopliteal disease in the East, there have been few randomized control trial for comparison of stent fracture and primary patency between different nitinol stents. Smart stent has the peak-to-valley bridge and in-line interconnection. Medtronics company have claimed Complete's stent crowns have been configured to minimize crown to crown interaction, increasing the stent's flexibility without compromising radial strength. We made the hypothesis that the design of Complete-SE stent might be more fracture-resistant or effective for in-stent restenosis, compared with Smart stent. On the other hand, 2011 ESC guideline recommended that dual antiplatelet therapy with aspirin and a thienopyridine for at least one month is recommended after infrainguinal bare-metal-stent implantation. Recent meta-analysis has shown that the efficacy of cilostazol in the atherosclerotic femoropopliteal lesion was proven. However, still specific data regarding a variety of antiplatelet regimen are limited. To date, there is no the study for comparison between clopidogrel and cilostazole in patient undergone stent implantation in femoropopliteal lesion. In conclusion, the purpose of our study is to examine and compare Primary patency and stent fracture between different two-nitinol stents (S.M.A.R.T. CONTROL versus Complete SE) and to compare binary restenosis rate between clopidogrel and cilostazol in femoropopliteal arterial lesion.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Five randomized, controlled trials failed to demonstrate any benefit of a stainless-steel stent over angioplasty alone. The nitinol stent has proven superior primary patency than balloon angioplasty in superficial femoral artery (SFA) lesions. Several studies reported stent fractures were associated with a higher risk of in-stent restenosis and reocclusion. In vitro, Stefan et al. reported the 7 different SFA stents showed differences in the incidence of high strain zones, which indicates a potential for stent fracture, as demonstrated by the mechanical fatigue tests. They claimed differences in stent design might play a major role in the appearance of stent strut fracture related to restenosis and reocclusion. Also, in retrospective study, Iida et al. reported there was significant difference in stent fracture between S.M.A.R.T. stent group and Luminexx stent group and primary patency was worse in those associated with stent fracture than in those without stent fractures. Recent stent design improvements focus on decreasing stent fracture rates which can negatively impact patency rates by rearranging strut alignment.

The design of self-expandible nitinol stents might be different depending on the developed time; The first-generation nitinol stents (e.g., LuminexxTM and SmartTM) showed a remarkably high rate of stent strut fracture. A second generation of slotted tube nitinol stents has been developed. These stents had a better flexibility, by reducing the number of connections between cells or crowns, and by configurating spiral orientation of these interconnections. Several studies reported that these nitinol stents are more fracture-resistant and more flexible, some of them providing superior patency rate (e.g., LifeTM and EverflexTM). However, the one of the important limitations to their studies is that those was the non-randomized study of relative small sample size or was confined to in-vitro. Upto date, the multicenter, randomized controlled trial for direct comparison of stent fracture and primary patency between two different nitinol stents has not been done except one study; SMART versus Luminexx stent. SMART and Luminexx stent have been classified into 1st generation self-expandable nitinol stent. Complete-SE stent of Medtronic company was different to Smart stent of Cordis company in that the configuration of interconnection of Complete-SE stent had peak-to-peak connection and more spiral orientation of interconnection, compared to mart stent. On the other hand, Smart stent has the peak-to-valley bridge and in-line interconnection. Medtronics company have claimed Complete's stent crowns have been configured to minimize crown to crown interaction, increasing the stent's flexibility without compromising radial strength. We made the hypothesis that the design of Complete-SE stent might be more fracture-resistant or effective for in-stent restenosis, compared with Smart stent.

On the other hand, to date, in previous many reports, the dual antiplatelet therapy consisted of aspirin and clopidogrel have proven to decrease the incidence of cardiovascular death, myocardial infarction, or revascularization without an increase in major bleeding in patients who underwent percutaneous coronary intervention regardless of stent type (bare metal stent or drug-eluting stent). In 2011 ESC (European society of cardiology) guideline, dual antiplatelet therapy with aspirin and a thienopyridine for at least one month is recommended after infra-inguinal bare metal stent implantation (Class I, Level C). However, there have been no the definite evidence or guideline for the optimal antiplatelet agents after stent implantation one month later. There have been many studies for the efficacy of thienopyridine in peripheral arterial disease. Also, With the potential benefit of cilostazol on vascular function in vitro, there have several previous efforts to prove the efficacy of cilostazol in patients undergoing endovascular therapy or stent implantation in peripheral arterial disease. However, still specific data regarding a variety of antiplatelet regimen are limited. Also, very few trials have effectively nor properly addressed the direct comparison for the efficacy and safety between clopidogrel and cilostazol. This trial designed to evaluate the efficacy and safety between aspirin plus clopidogrel versus aspirin plus cilostazol in patients undergoing stent implantation in femoropopliteal lesions.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Arterial Disease Atherosclerosis

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

RANDOMIZED

Intervention Model

PARALLEL

Primary Study Purpose

TREATMENT

Blinding Strategy

NONE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Complete SE Stent

study design is 2x2 randomization design. First, before randomization, stratification will be performed according to lesion length 15cm criteria at web-based computerized program. Patients will be randomized in a 1:1 manner according to different two (SMART versus Complete-SE) stents. And then, patients received aspirin and clopidogrel during one month. After one month from index procedure, patients were randomized to receive either clopidogrel group (clopidogrel will not be changed but continue) or cilostazol group (clopidogrel will be changed into cilostazol) in separate groups of SMART group and Complete SE group. Randomization procedure will be performed using a web-based program

Group Type EXPERIMENTAL

Complete SE Stent

Intervention Type DEVICE

same to SMART CONTROL Stent

SMART CONTROL Stent

same to Complete SE

Group Type ACTIVE_COMPARATOR

S.M.A.R.T CONTROL Stent

Intervention Type DEVICE

Provisional stenting should be performed; the case that optimal ballooning response is not obtained (sub-optimal balloon response) should be enrolled. The procedure is usually done, as follows; After the guidewire is passed through the target lesion, predilation of the target lesion with an optimally sized balloon will be performed prior to stent implantation. Recommended, minimal balloon dilation time is 120 seconds. The sub-optimal balloon response is defined as a residual pressure gradient of \>15 mmHg, residual stenosis of \>30%, and flow-limiting dissection.

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

S.M.A.R.T CONTROL Stent

Provisional stenting should be performed; the case that optimal ballooning response is not obtained (sub-optimal balloon response) should be enrolled. The procedure is usually done, as follows; After the guidewire is passed through the target lesion, predilation of the target lesion with an optimally sized balloon will be performed prior to stent implantation. Recommended, minimal balloon dilation time is 120 seconds. The sub-optimal balloon response is defined as a residual pressure gradient of \>15 mmHg, residual stenosis of \>30%, and flow-limiting dissection.

Intervention Type DEVICE

Complete SE Stent

same to SMART CONTROL Stent

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Clinical criteria

1. Age 20 years of older
2. Symptomatic peripheral-artery disease with (Rutherford 2 - 6); moderate to severe claudication (Rutherford 2-3), chronic critical limb ischemia with pain while was at rest (Rutherford 4), or with ischemic ulcers (Rutherford 5-6)
3. Patients with signed informed consent
* Anatomical criteria

1. Stenosis of \>50% or occlusive atherosclerotic lesion of the ipsilateral femoropopliteal artery
2. Patent (≤50% stenosis) ipsilateral iliac artery or concomitantly treatable ipsilateral iliac lesions (≤30% residual stenosis),
3. At least one patent (less than 50% stenosed) tibioperoneal run-off vessel.

Exclusion Criteria

1. Disagree with written informed consent
2. Major bleeding history within prior 2 months
3. Known hypersensitivity or contraindication to any of the following medication: heparin, aspirin, clopidogrel, cilostazol, or contrast agent
4. Acute limb ischemia
5. Previous bypass surgery or stenting of the ipsilateral femoropopliteal artery
6. Untreated inflow disease of the ipsilateral pelvic arteries (more than 50% stenosis or occlusion)
7. Patients that major amputation ("above the ankle" amputation) has been done, is planned or required
8. Patients with life expectancy \<1 year due to comorbidity
Minimum Eligible Age

20 Years

Maximum Eligible Age

90 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Korea University Guro Hospital

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Seung Woon Rha

Clinical Professor

Responsibility Role PRINCIPAL_INVESTIGATOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Seung-Woon Rha, MD, PhD

Role: PRINCIPAL_INVESTIGATOR

Cardiovascular Center, Korea University Guro Hospital, 80, Guro-dong, Guro-gu, Seoul, 152-703, Korea

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Cardiovascular center, Korea University Guro Hospital

Seoul, , South Korea

Site Status

Korea University Guro Hospital

Seoul, , South Korea

Site Status

Countries

Review the countries where the study has at least one active or historical site.

South Korea

References

Explore related publications, articles, or registry entries linked to this study.

Park SH, Rha SW, Choi CU, Kim EJ, Oh DJ, Cho YH, Choi WG, Lee SJ, Kim YH, Choi SH, Kim WH, Kim KC, Cho JH, Kim JH, Kim SM, Bae JH, Bong JM, Kang WY, Baek JY, Seo JB, Chung WY, Park MW, Her SH, Suh J, Kim MW, Kim YJ, Choi HJ, Soh JW; SENS-FP Investigators. Efficacy of two different self-expanding nitinol stents for atherosclerotic femoropopliteal arterial disease (SENS-FP trial): study protocol for a randomized controlled trial. Trials. 2014 Sep 10;15:355. doi: 10.1186/1745-6215-15-355.

Reference Type DERIVED
PMID: 25208688 (View on PubMed)

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

SENS-FP

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

Absolute Pro® MOMENTUM™
NCT01444378 COMPLETED NA