Efficiency Study Evaluating the Use of PVAC Catheter Technology for Performing Ablation in Pts With Atrial Fibrillation

NCT ID: NCT01562912

Last Updated: 2018-03-29

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Clinical Phase

NA

Total Enrollment

230 participants

Study Classification

INTERVENTIONAL

Study Start Date

2012-02-29

Study Completion Date

2018-03-31

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

Atrial fibrillation (AF) is the most common arrhythmia affecting the Canadian population. AF is associated with increased risk of stroke,HF, and even mortality. AF can cause debilitating symptoms, adversely affect patient's (pt's) quality of life and functional status. Hence a strategy of sinus rhythm (SR) may be pursued over a strategy of allowing AF to persist. Percutaneous catheter ablation is an effective alternative to antiarrhythmic drugs (AAD) for maintaining SR. The success rate of PV isolation off AAD is about 80-90% in pt's with PAF, but repeat procedures are required in up to 40% of pt's. After one ablation, the success rate may only be 50-70% off drugs.Current standard ablation procedures for PV antral isolation employ mapping systems which reconstructions of the LA and PV anatomy are created. Visualization may be supplemented by integration of CT/ MRI images and/or intracardiac echocardiography. Robotic navigation has been employed to assist in ablation. Based on single point unipolar radiofrequency (RF) ablation catheter where lesions are created point-by-point around the PVs to obtain electrical isolation.This results in lengthy complex, costly procedures,often more than 4 hours, which requires high degree of operator skill.Creation of contiguous, transmural lesions is challenging with standard single-point RF. A novel multipolar catheter ablation system has been evaluated for achieving PV isolation (PVAC catheter, Medtronic Inc.) An over-the-wire circular mapping/ablation catheter can be advanced into the PV antrum, and multiple lesions around the circumference of the catheter can be delivered simultaneously using duty-cycled unipolar and bipolar RF energy. Early reports, the system can achieve complete PV isolation with reduced fluoroscopy and procedural times using lower powers to achieve more reliable lesion sets.Long-term efficacy also seems comparable to standard RF ablation.This novel technology has potential to broaden the application of AF ablation, making procedures less time-consuming, less complex without compromising procedural efficacy. Published data PVAC technology outcomes are limited to studies with small sample sizes of 12-102 pt's. Data has been restricted to a small number of European centers performing moderate numbers of PVAC procedures. There is no prospective, multicenter data. Little is known about the efficiency of PVAC procedures, allowing for an assessment of cost-effectiveness in using this technology.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

This is a multicenter, open label, prospective, cohort study. Patients undergoing ablation with PVAC technology in up to 15 centers across Canada will be enrolled, ablated, and followed for one year post-ablation. Both primary and secondary objectives of the study will be determined from this cohort of patients. Comparisons to the traditional ablation methods will be made by collecting data from a prospective group of control subjects who are undergoing AF ablation with traditional ablation technology at the same centers by the same operators. Control patients will be enrolled in a 1:2 ratio compared to the PVAC cohort. While the final ratio of control to PVAC patients must be 1:2 by study end for each operator, the ratio may vary while the study is conducted to allow some flexibility in patient recruitment. However, the absolute difference between \[# of PVAC patients\] and 2x\[# control patients\] should not exceed 5 at any given time for any operator in any study center

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Atrial Fibrillation

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

NON_RANDOMIZED

Intervention Model

PARALLEL

Primary Study Purpose

TREATMENT

Blinding Strategy

NONE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Control

Radiofrequency Ablation Procedure. Subjects who are undergoing AF ablation with traditional ablation technology at the same centers by the same operators. Control patients will be enrolled in a 1:2 ratio compared to the PVAC cohort. Intervention is the use of Radiofrequency Ablation.

Group Type ACTIVE_COMPARATOR

Radiofrequency Ablation Procedure

Intervention Type DEVICE

Application of radiofrequency energy will be delivered during PV antral isolation procedure and should be performed with a standard, open irrigated ablation catheter and a mapping system as the investigator would perform the procedure normally.

PVAC Ablation Procedure

Intervention is the use of PVAC technology. The PVAC is deployed in the left atrium over a 0.032-inch guidewire inside the PV and advanced until it is wedged within the antrum proximal to the ostium. Energy is delivered through selected electrode pairs with local potentials as well as adjacent electrode pairs, allowing bipolar current to flow to the target electrode(s) from both sides. Each application lasts for 60 seconds. When the temperature does not rise above 50°C within 15 seconds, the application should be discontinued to improve position. The PVAC may be manipulated within the antrum to ablate in a pattern of overlapping circular lesions.

Group Type EXPERIMENTAL

PVAC Ablation Procedure

Intervention Type DEVICE

Application of radiofrequency energy with the Pulmonary Vein Ablation Catheter(PVAC)to eliminate potentials arising from the pulmonary veins.

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Radiofrequency Ablation Procedure

Application of radiofrequency energy will be delivered during PV antral isolation procedure and should be performed with a standard, open irrigated ablation catheter and a mapping system as the investigator would perform the procedure normally.

Intervention Type DEVICE

PVAC Ablation Procedure

Application of radiofrequency energy with the Pulmonary Vein Ablation Catheter(PVAC)to eliminate potentials arising from the pulmonary veins.

Intervention Type DEVICE

Other Intervention Names

Discover alternative or legacy names that may be used to describe the listed interventions across different sources.

THERMOCOOL Catheter, Biosense Webster EnSite NavX Velocity, St Jude LASSO Circular Mapping Catheter, Biosense Webster PVAC Catheter, Medtronic Inc., Ablation Frontiers

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Patients aged 18 years or greater.
* Patients undergoing first-time catheter ablation for AF.
* Patients with paroxysmal AF. Paroxysmal AF will be defined as self-terminating episodes less than 7 days duration. Patients should have had at least 3 episodes of AF in a one year period.
* Patients with symptomatic AF that is refractory to at least one antiarrhythmic medication. "Symptomatic" patients are those who have been aware of their AF anytime within the last 5 years prior to enrollment. Symptoms may include, but are not restricted to, palpitations, shortness of breath, chest pain, fatigue, or any combination of the above.
* At least one episode of AF must have been documented by ECG, Holter, loop recorder, telemetry, or transtelephonic monitoring within 24 months of enrollment in the study.
* Patients must be able and willing to provide written informed consent to participate in the clinical study.

Exclusion Criteria

* Patients with persistent AF (defined as an episode of AF lasting \>7 days).
* Patients with AF felt to be secondary to an obvious reversible cause.
* Patients with contraindications to systemic anticoagulation with heparin or warfarin or a direct thrombin inhibitor.
* Patients who have previously undergone AF ablation.
* Patients with left atrial size \>/= 55 mm (2D echocardiography, parasternal long axis view).
* Patients who are or may potentially be pregnant.
Minimum Eligible Age

18 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Medtronic

INDUSTRY

Sponsor Role collaborator

Newmarket Electrophysiology Research Group Inc

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Responsibility Role SPONSOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Atul Verma, MD

Role: PRINCIPAL_INVESTIGATOR

Newmarket Electrophysiology Research Group

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Hamilton Health Sciences

Hamilton, Ontario, Canada

Site Status

London Health Sciences Center

London, Ontario, Canada

Site Status

Southlake Regional Health Centre

Newmarket, Ontario, Canada

Site Status

McGill University Health Centre

Montreal, Quebec, Canada

Site Status

Hôpital Sacré-Coeur de Montréal

Montreal, Quebec, Canada

Site Status

Institut universitaire de cardiologie et de pneumologie de Québec

Québec, Quebec, Canada

Site Status

Countries

Review the countries where the study has at least one active or historical site.

Canada

References

Explore related publications, articles, or registry entries linked to this study.

Essebag V, Azizi Z, Alipour P, Khaykin Y, Leong-Sit P, Sarrazin JF, Sturmer M, Morillo C, Terricabras M, Amit G, Roux JF, Patterson S, Verma A. Relationship between quality of life and burden of recurrent atrial fibrillation following ablation: CAPCOST multicentre cohort study. Europace. 2020 Jul 1;22(7):1017-1025. doi: 10.1093/europace/euaa066.

Reference Type DERIVED
PMID: 32531030 (View on PubMed)

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

NERG-01

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

Prevention to Improve Outcomes After PVI
NCT05148338 ACTIVE_NOT_RECRUITING NA