Drug Eluting Stents In The Critically Ischemic Lower Leg 2

NCT ID: NCT01442636

Last Updated: 2015-03-09

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Clinical Phase

PHASE2/PHASE3

Total Enrollment

60 participants

Study Classification

INTERVENTIONAL

Study Start Date

2011-07-31

Study Completion Date

2014-11-30

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

The objective of this clinical evaluation is to evaluate the immediate and long term (up to 12 months) outcome of the XIENCE PRIME Everolimus Eluting Coronary Stent System (Abbott Vascular) in a controlled prospective investigation for the treatment of patients with critical limb ischemia due to the presence of lesions between 3cm and 10cm in length at the level of the below the knee arteries. Specifically the trial aims to illicit angiographic and ultrasound patency, clinical improvement, and adverse events associated with the use of this stent. The trial design is single armed, prospective, controlled trial run over 12 months of follow-up.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

The aim of this research is to evaluate the immediate and long term outcome of the XIENCE PRIME EverolimusEluting Coronary Stent System in a prospective investigation for the treatment of patients with critical limb ischemia due to the presence of lesions between 3cm and 10cm in length at the level of the below the knee arteries.

The research question is "Dose the use of an Everolimus coated stent in long tibial artery occlusions, between 3 and 10cm offer superior patency at 12 months compared to a historical cohort of bare metal stents in similar lesions?" Our hypothesis is that the use of everolimus coated stents in tibial artery occlusions between 3 and 10cm will result in lower binary restenosis than was historically found in equivalent but non-drugcoated bare metal stents.

Currently, there is evidence that angioplasty and drug eluting stents can be used as a therapy for patients with critical limb ischemia due to occlusive infrapopliteal disease. The XIENCE PRIME™ Everolimus Eluting Coronary Stent System (XIENCE PRIME EECSS or XIENCE PRIME stent system) is manufactured by Abbott. It is a device/drug combination product consisting of the CobaltChromium MULTILINK VISION 8 Coronary Stent System coated with a formulation containing everolimus, the active ingredient, embedded in a nonerodible polymer. The XIENCE PRIME Everolimus Eluting Coronary Stent is coated with everolimus (active ingredient), embedded in a nonerodible polymer (inactive ingredient). Everolimus is the active pharmaceutical ingredient in the XIENCE PRIME stent. It is a novel semisynthetic macrolide immunosuppressant, synthesized by chemical modification of rapamycin (sirolimus). The everolimus chemical name is 40O(2hydroxyethyl) rapamycin.

The XIENCE PRIME stent contains inactive ingredients including poly n-butyl methacrylate (PBMA), a polymer that adheres to the stent and drug coating, and PVDFHFP, which is comprised of vinylidene fluoride and hexafluoropropylene monomers as the drug matrix layer containing everolimus. PBMA is a homopolymer with a molecular weight (Mw) of 264,000 to 376,000 dalton. PVDFHFP is a nonerodible semicrystalline random copolymer with a molecular weight (Mw) of 254,000 to 293,000 dalton. The drug matrix copolymer is mixed with everolimus (83%/17% w/w polymer/everolimus ratio) and applied to the entire PBMA coated stent surface. The drug load is 100 μg/cm2 for all product sizes. No top-coat layer is used.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Peripheral Arterial Disease

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

NA

Intervention Model

SINGLE_GROUP

Primary Study Purpose

TREATMENT

Blinding Strategy

NONE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Xience Prime stent

Patients with critical limb ischemia due to below the knee arterial lesion between 30 and 100mm in length, treated with the XIENCE PRIME™ Everolimus Eluting Coronary Stent System.

Group Type EXPERIMENTAL

stent

Intervention Type DEVICE

Implantation of one or more Everolimus-eluting XIENCE PRIME™ Everolimus Eluting Coronary Stent Systems.

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

stent

Implantation of one or more Everolimus-eluting XIENCE PRIME™ Everolimus Eluting Coronary Stent Systems.

Intervention Type DEVICE

Other Intervention Names

Discover alternative or legacy names that may be used to describe the listed interventions across different sources.

Xience Prime stent

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Patient presenting with rest pain or minor tissue loss (Rutherford class 4 or 5)
* Patient is willing to comply with specified follow-up evaluations at the specified times
* Patient is \>18 years old
* Patient understands the nature of the procedure and provides written informed consent, prior to enrolment in the study
* Patient has a projected life-expectancy of at least 12 months
* Patient is eligible for treatment with the XIENCE PRIME stent (Abbott Vascular)
* Male, infertile female, or female of child bearing potential practicing an acceptable method of birth control with a negative pregnancy test within 7 days prior to study procedure


* De novo lesion or restenotic lesion after PTA in the infrapopliteal arteries, suitable for endovascular therapy
* Total target lesion length minimally 30mm and maximally 100mm
* Target vessel diameter visually estimated to be \>2.0mm and \<3.5mm
* Guidewire and delivery system successfully traversed lesion

Exclusion Criteria

* Patient refusing treatment
* The reference segment diameter is not suitable for the available stent design
* Untreated flow-limiting inflow lesions
* Perioperative unsuccessful ipsilateral percutaneous vascular procedure to treat inflow disease just prior to enrollment
* Any previous surgery in the target vessel (including prior ipsilateral crural bypass)
* Aneurysm in the target vessel
* Non-atherosclerotic disease resulting in occlusion (e.g. embolism, Buerger's disease, vasculitis)
* Severe medical comorbidities (untreated CAD/CHF, severe COPD, metastatic malignancy, dementia, etc) or other medical condition that would preclude compliance with the study protocol or 1-year life expectancy
* Major distal amputation (above the transmetatarsal) in the study limb or non-study limb
* Septicemia or bacteremia
* Any previously known coagulation disorder, including hypercoagulability
* Contraindication to anticoagulation or antiplatelet therapy
* Known allergies to stent or stent components
* Known allergy to contrast media that cannot be adequately pre-medicated prior to the study procedure
* Patient with known hypersensitivity to heparin, including those patients who have had a previous incidence of heparin-induced thrombocytopenia (HIT) type II
* Currently participating in another clinical research trial
* Angiographic evidence of intra-arterial thrombus or atheroembolism from inflow treatment
* Target lesion access not performed by transfemoral approach.
Minimum Eligible Age

18 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Flanders Medical Research Program

NETWORK

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Responsibility Role SPONSOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Marc Bosiers, MD

Role: PRINCIPAL_INVESTIGATOR

A.Z. Sint-Blasius Hospital

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Prince of Wales Private Hospital

Randwick, New South Wales, Australia

Site Status

Imelda Hospital

Bonheiden, Antwerp, Belgium

Site Status

Department Vascular Surgery, A.Z. Sint-Blasius Hospital

Dendermonde, East-Flanders, Belgium

Site Status

Herz-zentrum Bad Krozingen

Bad Krozingen, , Germany

Site Status

Herzzentrum

Leipzig, , Germany

Site Status

St Fransiskus hospital

Münster, , Germany

Site Status

Countries

Review the countries where the study has at least one active or historical site.

Australia Belgium Germany

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

FMRP-101021

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

EXCEL Clinical Trial
NCT01205776 COMPLETED NA