BIfurcation Optimal Treatment Strategy With LYMus Eluting Dedicated Bifurcation Versus Convention Stent Randomized Study
NCT ID: NCT01430364
Last Updated: 2013-12-25
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
UNKNOWN
PHASE4
60 participants
INTERVENTIONAL
2011-09-30
2014-05-31
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Even after the introduction of drug-eluting stents (DES) in the treatment of coronary bifurcation lesions, important basic problems remain. It was proposed that these problems are related to non-dedicated design of conventional stent intended for treatment of straight vessel segments. Thus any deformation of the stents during bifurcation implantation depends on the stent cell shape, size and material properties (11). To resolve these problems it was suggested to make dedicated bifurcation stents (1, 2, 11). However, the special "dedication" per se is not defined and unclear as terminology - the stent could be dedicated for patient fitting the anatomical characteristics of particular bifurcation point (vessel diameters, angulations), giving better hemodynamic conditions; or stent could be dedicated for operator to make the procedure quicker and safer, eliminating or limiting SB compromise. Probably the best option is the combination of both characteristics.
The currently available stents on the market generally target the second requirement. Three groups of stents are available at this moment - proximal main vessel (MV) stent (Axxess, Devax, USA), MV stenting across the SB with different designs making possible permanent access to SB and finally purely SB dedicated stents (Tryton, Sideguard, Biguard). Neither of these stents did not match proximal - distal MV size difference nor take into account between vessel angulations. The device success rate varies considerably (75% - 100%); however the study with 100% success was performed in only 11 patients. For all other devices the success rate is around 85%. The proximal MV stent and SB only stents require additional stent implantation for non-intended vessel. Stents designed to have permanent access to SB are implanted over 2 wires, which in reality makes the procedure more difficult and demanding rather to simplify it (which was the primary intention of those stents). The reasons are wires crisscrossing, wire-bias in proper orientation of device to SB (rotational and axial positioning). This, along with requirement of larger guide catheter size explains why the dedicated stents do not gain popularity in the interventional cardiology community.
The BiOSS Lim stent (Balton, Warsaw, Poland) is completely different from the above systems. The stent is designed to be user friendly: it tracked over one wire and its profile is quite low (1.08mm), which make it possible to implant it even through 5 Fr guiding catheter. The stent fits the bifurcation anatomy - it matches the proximal - distal diameters of the main vessel (MV); as it permits deformation in its mid-part it can adapt exactly on main vessel - main branch angle angle, making wide opening to SB. If the SB must be dilated the stent recrossing is very easy, because wider proximal and narrow distal parts give step-down at carina tip region, in this way self direct wire to SB. The proximal and distal parts of the stent work independently and SB could be safely dilated without need from kissing balloon inflation as no deformation of contralateral wall strut. This simplifies and shortens the procedure. And finally, the stent construction prevents carina displacement, as a basic mechanism of side branch compromise.
Study aims: to compare two intervention strategies for bifurcation treatment - provisional T-stenting (PTS) with drug-eluting stent (sirolimus eluting), with kissing balloon inflation at the end of procedure - the best treatment strategy at the moment, with stenting of bifurcation lesions with dedicated bifurcation drug-eluting stent BiOSS Lym.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Keywords
Explore important study keywords that can help with search, categorization, and topic discovery.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
RANDOMIZED
SINGLE_GROUP
TREATMENT
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
BIOSS implantation
BIOSS LIM implantation
BIOSS LIM is a dedicated bifurcation stent system with sirolymus elution.
BIOSS Lim
CarloS
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
BIOSS LIM implantation
BIOSS LIM is a dedicated bifurcation stent system with sirolymus elution.
BIOSS Lim
CarloS
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Subject able to verbally confirm understandings of risks, benefits of receiving PCI for true bifurcation lesions, and he/she or his/her legally authorized representative provides written informed consent prior to any study related procedure.
* Target main branch lesion(s) located in a native coronary artery with diameter of ≥ 2.5 mm and ≤ 4.5 mm. Target side branch lesion(s) located in a native coronary artery with diameter of ≥ 2.0 mm.
* Target lesion(s) amenable for PCI with balloon angioplasty of the side branch.
Exclusion Criteria
* Non-cardiac co-morbid conditions are present with life expectancy \<1 year or that may result in protocol non-compliance (per site investigator's medical judgment).
* Subjects who refuse to give informed consent.
* Subjects with LVEF\<30%
* Subjects with moderate or severe degree valvular heart disease or primary cardiomyopathy
* Contraindications for 12 months DAP
20 Years
90 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Medica Cor Heart Hospital
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Medica Cor Heart Hospital
Rousse, , Bulgaria
Countries
Review the countries where the study has at least one active or historical site.
Central Contacts
Reach out to these primary contacts for questions about participation or study logistics.
Facility Contacts
Find local site contact details for specific facilities participating in the trial.
Dobrin Vassilev, MD, PhD
Role: primary
Kristiyan Ivanov, MD
Role: backup
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
BIOSS LIM
Identifier Type: -
Identifier Source: org_study_id