Treatment of Coronary ARtery bIfurcation Narrowing by AXxess Stent Implantation

NCT ID: NCT02486315

Last Updated: 2024-03-05

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Total Enrollment

326 participants

Study Classification

OBSERVATIONAL

Study Start Date

2012-04-30

Study Completion Date

2015-06-30

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

The Axxess™ Biolimus A9™ Eluting Coronary Bifurcation Stent System (AXXESS System; Biosensors, International, Morges, Switzerland) is a dedicated bifurcation stent, designed to cover the lesion at the level of the carina. Although deemed ideal for lesions involving only the proximal MV (1,0,0 according to Medina classification ref), this device may be used also in more complex bifurcation lesions when additional DES are required in the distal MV and/or in the SB. In the present registry the investigators report the performance and the efficacy of the self-expanding biolimus-eluting AxxessTM stent for the treatment of bifurcation lesions in a real-world population.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Despite a comprehensive understanding of the physiological and technical issues regarding the coronary bifurcations lesions, percutaneous coronary intervention (PCI) in this setting remains challenging. When compared with non-bifurcation lesions, treatment of bifurcation lesions is associated with increased adverse clinical events and inferior angiographic outcomes including procedural complications. This is due to several technical challenges, including both anatomical (proximal-to-distal vessel mismatch \[tapering\], angulation and calcification) and procedural (plaque shift, and side-branch \[SB\] closure) features. Current balloon-expandable drug-eluting stent (DES) have not been designed to treat the bifurcation lesions; in particular, the inability of DES to adequately scaffold and preserve the ostium of SB represents a the major reason of failure, because this is the most common site for restenosis. Recently a large variety of dedicated bifurcation stents have been developed in order to 1) provide an easier access to the SB and to scaffold more effectively its ostium, and 2) adapt to main vassel (MV) tapering, and to the bifurcation anatomy.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Coronary Artery Disease

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Observational Model Type

COHORT

Study Time Perspective

PROSPECTIVE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

AXXESS stent

all consecutive patients with de novo bifurcation lesions treated at the Clinica Mediterranea (Naples) and at the "Sapienza" University (Rome) were screened for potential inclusion in the present study. Inclusion angiographic criteria were: 1) significant (≥70% diameter stenosis) bifurcation lesion; 2) MV reference diameter between 2.75 and 4.75 mm by visually estimated, 3) SB reference diameter ≥2.25 mm by visual estimate; 4) bifurcation angle (between the distal MV and the SB) \<70° by visual estimate. Both protected and unprotected left main bifurcation lesions were allowed to be included, provided that all previous angiographic criteria were satisfied. Patients deemed eligible underwent AXXESS stent implantation

AXXESS stent

Intervention Type DEVICE

Axxess stent is a conically-shaped, self-expanding nitinol stent, with a 0.006-inch strut thickness, specifically designed to preserve and to match the anatomy of the bifurcation at the carina level. The stent is coated with Biolimus A9™, a highly lipophilic, semi-synthetic sirolimus analogue, immersed in the biodegradable polylactic acid (PLA) applied primarily to the abluminal surface. PLA completely dissolves after 6 to 9 months.The stent has 3 radiopaque markers at the distal end and one at the proximal end to aid in the visibility and placement. The AxxessTM stent is 7 Fr guiding catheter or Sheathless Guiding Catheter compatible. During the study period, the AxxessTM stent was available in 3 different diameters (3.0, 3.5 and 4.0 mm) and lengths (9, 10 and 14 mm)

Control group

The control group is represented by patients with coronary bifurcation lesions treated with conventional techniques and standard balloon expandable drud eluting stents.

This group was found retrospectively through a propensity score matching.

No interventions assigned to this group

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

AXXESS stent

Axxess stent is a conically-shaped, self-expanding nitinol stent, with a 0.006-inch strut thickness, specifically designed to preserve and to match the anatomy of the bifurcation at the carina level. The stent is coated with Biolimus A9™, a highly lipophilic, semi-synthetic sirolimus analogue, immersed in the biodegradable polylactic acid (PLA) applied primarily to the abluminal surface. PLA completely dissolves after 6 to 9 months.The stent has 3 radiopaque markers at the distal end and one at the proximal end to aid in the visibility and placement. The AxxessTM stent is 7 Fr guiding catheter or Sheathless Guiding Catheter compatible. During the study period, the AxxessTM stent was available in 3 different diameters (3.0, 3.5 and 4.0 mm) and lengths (9, 10 and 14 mm)

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

1. significant (≥70% diameter stenosis) bifurcation lesion;
2. MV reference diameter between 2.75 and 4.75 mm by visually estimated
3. SB reference diameter ≥2.25 mm by visual estimate;
4. bifurcation angle (between the distal MV and the SB) \<70° by visual estimate

Exclusion Criteria

1. patients with contraindications to prolonged dual-antiplatelet therapy,
2. known sensitivity to "limus" compounds, stainless steel, titanium, or nickel;
3. inclusion in others studies on bifurcation lesions; and
Minimum Eligible Age

18 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Clinica Mediterranea

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Carlo Briguori

MD, PhD

Responsibility Role PRINCIPAL_INVESTIGATOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Carlo Briguori, MD,PhD

Role: PRINCIPAL_INVESTIGATOR

Clinica Mediterranea

References

Explore related publications, articles, or registry entries linked to this study.

Latib A, Colombo A. Bifurcation disease: what do we know, what should we do? JACC Cardiovasc Interv. 2008 Jun;1(3):218-26. doi: 10.1016/j.jcin.2007.12.008.

Reference Type BACKGROUND
PMID: 19463303 (View on PubMed)

Wykrzykowska JJ, Grundeken MJ, Stankovic G, Di Mario C. Is there a need for dedicated devices? EuroIntervention. 2015;11 Suppl V:V139-42. doi: 10.4244/EIJV11SVA31.

Reference Type BACKGROUND
PMID: 25983149 (View on PubMed)

Grube E, Buellesfeld L, Neumann FJ, Verheye S, Abizaid A, McClean D, Mueller R, Lansky A, Mehran R, Costa R, Gerckens U, Trauthen B, Fitzgerald PJ. Six-month clinical and angiographic results of a dedicated drug-eluting stent for the treatment of coronary bifurcation narrowings. Am J Cardiol. 2007 Jun 15;99(12):1691-7. doi: 10.1016/j.amjcard.2007.01.043. Epub 2007 May 7.

Reference Type BACKGROUND
PMID: 17560877 (View on PubMed)

Buysschaert I, Dubois CL, Dens J, Ormiston J, Worthley S, McClean D, Ottervanger JP, Meredith I, Uren N, Wijns W, Whitbourn R, Mehran R, Lansky AJ, Bichalska M, Meis S, Verheye S. Three-year clinical results of the Axxess Biolimus A9 eluting bifurcation stent system: the DIVERGE study. EuroIntervention. 2013 Sep;9(5):573-81. doi: 10.4244/EIJV9I5A93.

Reference Type BACKGROUND
PMID: 24058075 (View on PubMed)

Hasegawa T, Ako J, Koo BK, Miyazawa A, Sakurai R, Chang H, Dens J, Verheye S, Grube E, Honda Y, Fitzgerald PJ. Analysis of left main coronary artery bifurcation lesions treated with biolimus-eluting DEVAX AXXESS plus nitinol self-expanding stent: intravascular ultrasound results of the AXXENT trial. Catheter Cardiovasc Interv. 2009 Jan 1;73(1):34-41. doi: 10.1002/ccd.21765.

Reference Type BACKGROUND
PMID: 19089934 (View on PubMed)

Garcia E, Unzue Vallejo L, Rodriguez-Rodrigo FJ. Placement of a single Axxess stent as new treatment strategy for Medina 1,0,0 left main stem bifurcation lesion. J Invasive Cardiol. 2014 Apr;26(4):E45-7.

Reference Type BACKGROUND
PMID: 24717281 (View on PubMed)

Louvard Y, Thomas M, Dzavik V, Hildick-Smith D, Galassi AR, Pan M, Burzotta F, Zelizko M, Dudek D, Ludman P, Sheiban I, Lassen JF, Darremont O, Kastrati A, Ludwig J, Iakovou I, Brunel P, Lansky A, Meerkin D, Legrand V, Medina A, Lefevre T. Classification of coronary artery bifurcation lesions and treatments: time for a consensus! Catheter Cardiovasc Interv. 2008 Feb 1;71(2):175-83. doi: 10.1002/ccd.21314.

Reference Type BACKGROUND
PMID: 17985377 (View on PubMed)

Lassen JF, Holm NR, Stankovic G, Lefevre T, Chieffo A, Hildick-Smith D, Pan M, Darremont O, Albiero R, Ferenc M, Louvard Y. Percutaneous coronary intervention for coronary bifurcation disease: consensus from the first 10 years of the European Bifurcation Club meetings. EuroIntervention. 2014 Sep;10(5):545-60. doi: 10.4244/EIJV10I5A97.

Reference Type BACKGROUND
PMID: 25256198 (View on PubMed)

Medina A, Suarez de Lezo J, Pan M. [A new classification of coronary bifurcation lesions]. Rev Esp Cardiol. 2006 Feb;59(2):183. No abstract available. Spanish.

Reference Type BACKGROUND
PMID: 16540043 (View on PubMed)

Noguchi T, Miyazaki MD S, Morii I, Daikoku S, Goto Y, Nonogi H. Percutaneous transluminal coronary angioplasty of chronic total occlusions. Determinants of primary success and long-term clinical outcome. Catheter Cardiovasc Interv. 2000 Mar;49(3):258-64. doi: 10.1002/(sici)1522-726x(200003)49:33.0.co;2-l.

Reference Type BACKGROUND
PMID: 10700054 (View on PubMed)

Thygesen K, Alpert JS, Jaffe AS, Simoons ML, Chaitman BR, White HD; Joint ESC/ACCF/AHA/WHF Task Force for the Universal Definition of Myocardial Infarction; Katus HA, Lindahl B, Morrow DA, Clemmensen PM, Johanson P, Hod H, Underwood R, Bax JJ, Bonow RO, Pinto F, Gibbons RJ, Fox KA, Atar D, Newby LK, Galvani M, Hamm CW, Uretsky BF, Steg PG, Wijns W, Bassand JP, Menasche P, Ravkilde J, Ohman EM, Antman EM, Wallentin LC, Armstrong PW, Simoons ML, Januzzi JL, Nieminen MS, Gheorghiade M, Filippatos G, Luepker RV, Fortmann SP, Rosamond WD, Levy D, Wood D, Smith SC, Hu D, Lopez-Sendon JL, Robertson RM, Weaver D, Tendera M, Bove AA, Parkhomenko AN, Vasilieva EJ, Mendis S. Third universal definition of myocardial infarction. Circulation. 2012 Oct 16;126(16):2020-35. doi: 10.1161/CIR.0b013e31826e1058. Epub 2012 Aug 24. No abstract available.

Reference Type BACKGROUND
PMID: 22923432 (View on PubMed)

Behan MW, Holm NR, Curzen NP, Erglis A, Stables RH, de Belder AJ, Niemela M, Cooter N, Chew DP, Steigen TK, Oldroyd KG, Jensen JS, Lassen JF, Thuesen L, Hildick-Smith D. Simple or complex stenting for bifurcation coronary lesions: a patient-level pooled-analysis of the Nordic Bifurcation Study and the British Bifurcation Coronary Study. Circ Cardiovasc Interv. 2011 Feb 1;4(1):57-64. doi: 10.1161/CIRCINTERVENTIONS.110.958512. Epub 2011 Jan 4.

Reference Type BACKGROUND
PMID: 21205942 (View on PubMed)

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

NCTC005

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

BGP+ Stent as Bridging Stent in BEVAR
NCT03982940 ACTIVE_NOT_RECRUITING NA
LEADERS FREE II: BioFreedom™ Pivotal Study
NCT02843633 ACTIVE_NOT_RECRUITING NA