Treatment of Coronary ARtery bIfurcation Narrowing by AXxess Stent Implantation
NCT ID: NCT02486315
Last Updated: 2024-03-05
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
326 participants
OBSERVATIONAL
2012-04-30
2015-06-30
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
PCI With AXXESS Biolimus A9 Eluting Bifurcation Stent in Treating Coronary Artery Bifurcation Disease
NCT02384629
COmplex Bifurcation PCI: AXXESS Device + Absorb BVS, vs Modified T Stenting With Absorb BVS
NCT02628288
Bare Metal Bifurcation Stent Clinical Trial in Humans
NCT00607321
Safety and Feasibility of the Injectable BL-1040 Implant
NCT00557531
Study of the RelayPro Thoracic Stent-Graft in Subjects With an Acute, Complicated Type B Aortic Dissection
NCT03033043
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
COHORT
PROSPECTIVE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
AXXESS stent
all consecutive patients with de novo bifurcation lesions treated at the Clinica Mediterranea (Naples) and at the "Sapienza" University (Rome) were screened for potential inclusion in the present study. Inclusion angiographic criteria were: 1) significant (≥70% diameter stenosis) bifurcation lesion; 2) MV reference diameter between 2.75 and 4.75 mm by visually estimated, 3) SB reference diameter ≥2.25 mm by visual estimate; 4) bifurcation angle (between the distal MV and the SB) \<70° by visual estimate. Both protected and unprotected left main bifurcation lesions were allowed to be included, provided that all previous angiographic criteria were satisfied. Patients deemed eligible underwent AXXESS stent implantation
AXXESS stent
Axxess stent is a conically-shaped, self-expanding nitinol stent, with a 0.006-inch strut thickness, specifically designed to preserve and to match the anatomy of the bifurcation at the carina level. The stent is coated with Biolimus A9™, a highly lipophilic, semi-synthetic sirolimus analogue, immersed in the biodegradable polylactic acid (PLA) applied primarily to the abluminal surface. PLA completely dissolves after 6 to 9 months.The stent has 3 radiopaque markers at the distal end and one at the proximal end to aid in the visibility and placement. The AxxessTM stent is 7 Fr guiding catheter or Sheathless Guiding Catheter compatible. During the study period, the AxxessTM stent was available in 3 different diameters (3.0, 3.5 and 4.0 mm) and lengths (9, 10 and 14 mm)
Control group
The control group is represented by patients with coronary bifurcation lesions treated with conventional techniques and standard balloon expandable drud eluting stents.
This group was found retrospectively through a propensity score matching.
No interventions assigned to this group
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
AXXESS stent
Axxess stent is a conically-shaped, self-expanding nitinol stent, with a 0.006-inch strut thickness, specifically designed to preserve and to match the anatomy of the bifurcation at the carina level. The stent is coated with Biolimus A9™, a highly lipophilic, semi-synthetic sirolimus analogue, immersed in the biodegradable polylactic acid (PLA) applied primarily to the abluminal surface. PLA completely dissolves after 6 to 9 months.The stent has 3 radiopaque markers at the distal end and one at the proximal end to aid in the visibility and placement. The AxxessTM stent is 7 Fr guiding catheter or Sheathless Guiding Catheter compatible. During the study period, the AxxessTM stent was available in 3 different diameters (3.0, 3.5 and 4.0 mm) and lengths (9, 10 and 14 mm)
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
2. MV reference diameter between 2.75 and 4.75 mm by visually estimated
3. SB reference diameter ≥2.25 mm by visual estimate;
4. bifurcation angle (between the distal MV and the SB) \<70° by visual estimate
Exclusion Criteria
2. known sensitivity to "limus" compounds, stainless steel, titanium, or nickel;
3. inclusion in others studies on bifurcation lesions; and
18 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Clinica Mediterranea
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Carlo Briguori
MD, PhD
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Carlo Briguori, MD,PhD
Role: PRINCIPAL_INVESTIGATOR
Clinica Mediterranea
References
Explore related publications, articles, or registry entries linked to this study.
Latib A, Colombo A. Bifurcation disease: what do we know, what should we do? JACC Cardiovasc Interv. 2008 Jun;1(3):218-26. doi: 10.1016/j.jcin.2007.12.008.
Wykrzykowska JJ, Grundeken MJ, Stankovic G, Di Mario C. Is there a need for dedicated devices? EuroIntervention. 2015;11 Suppl V:V139-42. doi: 10.4244/EIJV11SVA31.
Grube E, Buellesfeld L, Neumann FJ, Verheye S, Abizaid A, McClean D, Mueller R, Lansky A, Mehran R, Costa R, Gerckens U, Trauthen B, Fitzgerald PJ. Six-month clinical and angiographic results of a dedicated drug-eluting stent for the treatment of coronary bifurcation narrowings. Am J Cardiol. 2007 Jun 15;99(12):1691-7. doi: 10.1016/j.amjcard.2007.01.043. Epub 2007 May 7.
Buysschaert I, Dubois CL, Dens J, Ormiston J, Worthley S, McClean D, Ottervanger JP, Meredith I, Uren N, Wijns W, Whitbourn R, Mehran R, Lansky AJ, Bichalska M, Meis S, Verheye S. Three-year clinical results of the Axxess Biolimus A9 eluting bifurcation stent system: the DIVERGE study. EuroIntervention. 2013 Sep;9(5):573-81. doi: 10.4244/EIJV9I5A93.
Hasegawa T, Ako J, Koo BK, Miyazawa A, Sakurai R, Chang H, Dens J, Verheye S, Grube E, Honda Y, Fitzgerald PJ. Analysis of left main coronary artery bifurcation lesions treated with biolimus-eluting DEVAX AXXESS plus nitinol self-expanding stent: intravascular ultrasound results of the AXXENT trial. Catheter Cardiovasc Interv. 2009 Jan 1;73(1):34-41. doi: 10.1002/ccd.21765.
Garcia E, Unzue Vallejo L, Rodriguez-Rodrigo FJ. Placement of a single Axxess stent as new treatment strategy for Medina 1,0,0 left main stem bifurcation lesion. J Invasive Cardiol. 2014 Apr;26(4):E45-7.
Louvard Y, Thomas M, Dzavik V, Hildick-Smith D, Galassi AR, Pan M, Burzotta F, Zelizko M, Dudek D, Ludman P, Sheiban I, Lassen JF, Darremont O, Kastrati A, Ludwig J, Iakovou I, Brunel P, Lansky A, Meerkin D, Legrand V, Medina A, Lefevre T. Classification of coronary artery bifurcation lesions and treatments: time for a consensus! Catheter Cardiovasc Interv. 2008 Feb 1;71(2):175-83. doi: 10.1002/ccd.21314.
Lassen JF, Holm NR, Stankovic G, Lefevre T, Chieffo A, Hildick-Smith D, Pan M, Darremont O, Albiero R, Ferenc M, Louvard Y. Percutaneous coronary intervention for coronary bifurcation disease: consensus from the first 10 years of the European Bifurcation Club meetings. EuroIntervention. 2014 Sep;10(5):545-60. doi: 10.4244/EIJV10I5A97.
Medina A, Suarez de Lezo J, Pan M. [A new classification of coronary bifurcation lesions]. Rev Esp Cardiol. 2006 Feb;59(2):183. No abstract available. Spanish.
Noguchi T, Miyazaki MD S, Morii I, Daikoku S, Goto Y, Nonogi H. Percutaneous transluminal coronary angioplasty of chronic total occlusions. Determinants of primary success and long-term clinical outcome. Catheter Cardiovasc Interv. 2000 Mar;49(3):258-64. doi: 10.1002/(sici)1522-726x(200003)49:33.0.co;2-l.
Thygesen K, Alpert JS, Jaffe AS, Simoons ML, Chaitman BR, White HD; Joint ESC/ACCF/AHA/WHF Task Force for the Universal Definition of Myocardial Infarction; Katus HA, Lindahl B, Morrow DA, Clemmensen PM, Johanson P, Hod H, Underwood R, Bax JJ, Bonow RO, Pinto F, Gibbons RJ, Fox KA, Atar D, Newby LK, Galvani M, Hamm CW, Uretsky BF, Steg PG, Wijns W, Bassand JP, Menasche P, Ravkilde J, Ohman EM, Antman EM, Wallentin LC, Armstrong PW, Simoons ML, Januzzi JL, Nieminen MS, Gheorghiade M, Filippatos G, Luepker RV, Fortmann SP, Rosamond WD, Levy D, Wood D, Smith SC, Hu D, Lopez-Sendon JL, Robertson RM, Weaver D, Tendera M, Bove AA, Parkhomenko AN, Vasilieva EJ, Mendis S. Third universal definition of myocardial infarction. Circulation. 2012 Oct 16;126(16):2020-35. doi: 10.1161/CIR.0b013e31826e1058. Epub 2012 Aug 24. No abstract available.
Behan MW, Holm NR, Curzen NP, Erglis A, Stables RH, de Belder AJ, Niemela M, Cooter N, Chew DP, Steigen TK, Oldroyd KG, Jensen JS, Lassen JF, Thuesen L, Hildick-Smith D. Simple or complex stenting for bifurcation coronary lesions: a patient-level pooled-analysis of the Nordic Bifurcation Study and the British Bifurcation Coronary Study. Circ Cardiovasc Interv. 2011 Feb 1;4(1):57-64. doi: 10.1161/CIRCINTERVENTIONS.110.958512. Epub 2011 Jan 4.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
NCTC005
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.