Digital Mammography for the Detection and Preoperative Staging of Breast Cancer
NCT ID: NCT01086514
Last Updated: 2015-09-30
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
NA
82 participants
INTERVENTIONAL
2010-03-31
2012-10-31
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
However, MRI is expensive, not always available, and some patients are unable to undergo MRI due to the presence of pacemakers, clips, or claustrophobia. Dual Energy Contrast Enhanced Digital Mammography (DE CEDM) is an investigational procedure that uses a non-standard contrast in a regular digital mammography exam that has been changed to give the needed dual energy and image. DE CEDM is not FDA approved. It is our hope that DE CEDM will also be able to detect unknown tumors because it will also detect new blood vessels. It is less expensive than MRI, could be more available to patients, and can be done on patients with pacemakers and clips. Claustrophobia will not be a problem. We plan to see if (DE CEDM) will help us better see the breast tumor and size of the breast tumor. We will also want to see if DE CEDM can detect additional unsuspected disease in the breast with the known tumor and in the other breast without a known tumor.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Comparison of Contrast-enhanced Spectral Mammography (CESM) to MRI in Screening High Risk Women for Breast Cancer
NCT02275871
Contrast-Enhanced Digital Mammography (CEDM) for Identifying a Change in Management of Women With Newly Diagnosed Breast Cancer
NCT01303419
DCE-MRI and MBI in Assessing Tumor Response to Chemotherapy in Patients With Triple Negative Breast Cancer
NCT02744053
Comparison of MRI and CEDM to Evaluate Treatment Response Before Surgery
NCT03070340
Breast MRI as a Preoperative Tool for DCIS
NCT00605982
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NA
SINGLE_GROUP
DIAGNOSTIC
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Dual Energy Contrast Enhanced Digital Mammography (DE CEDM)
In this study we will perform Dual Energy Contrast Enhanced Digital Mammography (DE CEDM) on patients with newly diagnosed breast cancer using a dedicated research system, derived from a standard digital mammography unit and review workstation (Senographe DS and SenoAdvantage) modified to deliver the required dual energy paired exposures and visualization of combined images.
Dual Energy Contrast Enhanced Digital Mammography (DE CEDM)
Each patient will have: Bilateral digital mammography, Bilateral Breast MRI, Bilateral Contrast Enhanced Digital Mammography. The latter examination is the only change in patient management. An additional contrast injection is involved. Results of the DE CEDM will be compared with routine digital mammography and breast MRI. The reference standard is pathology. If surgery is to be done; every attempt will be made to perform all imaging exams within 30 days.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Dual Energy Contrast Enhanced Digital Mammography (DE CEDM)
Each patient will have: Bilateral digital mammography, Bilateral Breast MRI, Bilateral Contrast Enhanced Digital Mammography. The latter examination is the only change in patient management. An additional contrast injection is involved. Results of the DE CEDM will be compared with routine digital mammography and breast MRI. The reference standard is pathology. If surgery is to be done; every attempt will be made to perform all imaging exams within 30 days.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Both breasts are present.
* Women consenting to a bilateral DE CEDM examination.
Exclusion Criteria
* Women who have already had a lumpectomy. (Index lesion has been removed and therefore, not evaluable for the purpose of this study.)
* Women undergoing neoadjuvant chemotherapy, hormone treatment, or radiation therapy.
* Known pregnancy.
* Women who have a contraindication to the intravenous use of iodinated or gadolinium-chelated contrast agent.
* Women with breast implants.
* Women with pacemakers.
* Women with aneurysm clips that don't allow for MRI.
* Women too claustrophobic to undergo MRI.
21 Years
FEMALE
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
GE Healthcare
INDUSTRY
Memorial Sloan Kettering Cancer Center
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Maxine Jochelson, MD
Role: PRINCIPAL_INVESTIGATOR
Memorial Sloan Kettering Cancer Center
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Memorial Sloan Kettering Cancer Center
New York, New York, United States
Countries
Review the countries where the study has at least one active or historical site.
Related Links
Access external resources that provide additional context or updates about the study.
Memorial Sloan Kettering Cancer Center
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
10-024
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.