Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
NA
442 participants
INTERVENTIONAL
2008-01-31
2008-12-31
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Ultrasound and Photoacoustic Imaging for Enhanced Differential Diagnosis of Rectal Cancer
NCT04339374
Neoplasia Detection With Methylene Blue MMX Tablets in Patients With UC Undergoing Colonoscopy
NCT01520324
Analysis of Extraperitoneal Rectal Neoplasms Between 3D Endorectal Ultrasonography and Magnification Chromoendoscopy
NCT04527939
Evaluating the Clinical Value of Transparent Cap-Assisted Second Examination of the Sigmoid Colon for Improving Colorectal Adenoma Detection Rates
NCT07261319
Endocytoscopy and Colorectal Neoplasia
NCT02324374
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Outcome measures: RC screening was carried out using a Tissue Resonance InterferoMeter probe (TRIMprobe) electromagnetic detector (Galileo Avionica, Turin, Italy), which consists of a nonlinear oscillator placed in a cylindrical probe about 30 cm long, a radiofrequency spectrum analyzer, and dedicated computer software. Detection of RC is based on the decrease of the electromagnetic signal compared to the mean signal obtained in healthy subjects. The test was performed while the patient stood 120 cm from the receiver. The operator was on the opposite side of the examined pelvis. No metallic objects were allowed on the patient and no electronic devices were admitted in the test area. The detector was kept at close contact to the pelvis surface and was moved through six planes, to obtain a scan of the whole pelvis volume. Based on the investigators previous study, we used the electromagnetic detection system at 465 MHz frequency, in a scale from 0 to 255 arbitrary U. The device lets the examination limited to the pelvis and we regarded the rectum cutoff within 15 cm from the anal verge.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NA
SINGLE_GROUP
DIAGNOSTIC
SINGLE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Electromagnetic measurement
Electromagnetic measurement to detect rectal cancer.
Electromagnetic measurement
RC screening was carried out using a Tissue Resonance InterferoMeter probe electromagnetic detector, which consists of a nonlinear oscillator placed in a cylindrical probe about 30 cm long, a radiofrequency spectrum analyzer, and dedicated computer software. Detection of RC is based on the decrease of the electromagnetic signal compared to the mean signal obtained in healthy subjects. The test was performed while the patient stood 120 cm from the receiver. The operator was on the opposite side of the examined pelvis. The detector was kept at close contact to the pelvis surface and was moved through six planes, to obtain a scan of the whole pelvis volume. Based on our previous study, we used the electromagnetic detection system at 465 MHz frequency, in a scale from 0 to 255 arbitrary U.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Electromagnetic measurement
RC screening was carried out using a Tissue Resonance InterferoMeter probe electromagnetic detector, which consists of a nonlinear oscillator placed in a cylindrical probe about 30 cm long, a radiofrequency spectrum analyzer, and dedicated computer software. Detection of RC is based on the decrease of the electromagnetic signal compared to the mean signal obtained in healthy subjects. The test was performed while the patient stood 120 cm from the receiver. The operator was on the opposite side of the examined pelvis. The detector was kept at close contact to the pelvis surface and was moved through six planes, to obtain a scan of the whole pelvis volume. Based on our previous study, we used the electromagnetic detection system at 465 MHz frequency, in a scale from 0 to 255 arbitrary U.
Other Intervention Names
Discover alternative or legacy names that may be used to describe the listed interventions across different sources.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
Exclusion Criteria
18 Years
95 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Fondazione IRCCS Istituto Nazionale dei Tumori, Milano
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Fondazione IRCCS Istituto Nazionale dei Tumori, Milano
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Fondazione IRCCS Istituto Nazionale Tumori
Milan, MI, Italy
Countries
Review the countries where the study has at least one active or historical site.
Related Links
Access external resources that provide additional context or updates about the study.
Fondazione IRCCS Istituto Nazionale Tumori, Milan, Italy
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
INT-D176767
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.