Clinical Trial Comparing Volar, Dorsal, and Custom Thermoplastic Splinting in the Treatment of Acute Mallet Finger
NCT ID: NCT00868686
Last Updated: 2009-03-25
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
PHASE3
77 participants
INTERVENTIONAL
2005-10-31
2008-07-31
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
The primary objective of this investigation was to show superiority of the custom thermoplastic splint over both the dorsal and volar non-custom splints. The null hypothesis was that a radiographic lag difference greater than 5 degrees would not be observed between groups. The primary outcome measure is the residual extensor lag difference (compared to the contralateral equivalent digit) at 12 weeks post-splinting.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Comparison of Splinting Interventions for Treating Mallet Finger Injuries
NCT00310570
Extension Block Technique Versus Splinting in Mallet Finger Fracture.
NCT01738919
Conservative Treatment of Mallet Finger Injury
NCT04830917
Comparative Study Between Micro Plate Fixation and Blocking k.Wire in Management of Acute Bony Mallet Finger : Randomized Controlled Clinical Trial Study
NCT06398483
Mallet Finger Splinting Study
NCT01388751
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Objectives. The primary objective of this investigation was to show superiority of the custom thermoplastic splint over both the dorsal and volar non-custom splints. The null hypothesis was that a radiographic lag difference greater than 5 degrees would not be observed between groups. The primary outcome measure is the residual extensor lag difference (compared to the contralateral equivalent digit) at 12 weeks post-splinting. Week-12 was chosen as a compromise between minimizing drop-out and the most distant timepoint reasonably obtainable.
A novel outcome lag measurement was developed for this study, using the contralateral normal digit as an internal control for establishing residual extensor lag. The residual extensor lag difference was calculated with a single radiograph obtained with the beam directed laterally at the affected digit and the contralateral equivalent digit (Figure 2). For example, if the injured mallet finger was the right index finger, a single lateral radiograph of the right and left index fingers on the same film was obtained. The patient was instructed to maximally extend the both digits. This allowed for accurate determination of extensor lag and comparison with the unaffected side . Adequacy of the lateral view was assessed by considering the superimposition of the phalangeal condyles of the affected digit. If they were not not superimposed, the radiograph was repeated.
A pilot study was performed to establish the most reliable technique for measuring residual lag radiographically. Three measurement techniques were trialled by individuals with three levels of training: resident, fellow, and consultant staff. A clearly defined technique was employed using digital images only (Inteleviewer, Intelerad, Montreal, Canada). The radiograph was enlarged on the viewing monitor so that the middle and distal phalanges maximally filled the screen. The techniques used bisecting lines for the middle and distal phalanges referencing either the volar cortex, dorsal cortex, or longitudinal axis of the phalanges (Figure 3). Twenty-six lateral finger radiographs were blinded and assessed, and then repeat measurements were obtained three weeks later. Inter-item correlation matrices and intraobserver Pearson's correlations showed extremely high correlation values ranging from 0.993 to 0.999 for the longitudinal axis technique. This pilot study established the longitudinal axis technique as the most reliable in measuring residual radiographic lag.
Several secondary objectives were investigated. These included correlations between residual lag and other factors, including patient age, Michigan Hand Outcome Questionnaire scores (MHQ) and the development of complications; incidence of complications in each splinting group; comparing radiographic to clinical extensor lag differences; and evaluating the course of residual lag after splinting has been discontinued. Exploratory analyses were performed as hypothesis generators only, including sub-group analysis.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
RANDOMIZED
PARALLEL
TREATMENT
SINGLE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Volar aluminum splint
Volar aluminum splint
Alumafoam strip with padding removed, placed on the VOLAR aspect of the digit spanning the middle and distal phalanges only.
Dorsal aluminum splint
Dorsal aluminum splint
Alumafoam strip with padding removed, placed on the DORSAL aspect of the digit spanning the middle and distal phalanges only.
Custom thermoplastic
Custom thermoplastic
Customized thermoplastic splint with circumferential contact proximal to the joint and volar contact distal to the joint. This is a similar design to the original Stack splint, except that it is custom molded.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Volar aluminum splint
Alumafoam strip with padding removed, placed on the VOLAR aspect of the digit spanning the middle and distal phalanges only.
Dorsal aluminum splint
Alumafoam strip with padding removed, placed on the DORSAL aspect of the digit spanning the middle and distal phalanges only.
Custom thermoplastic
Customized thermoplastic splint with circumferential contact proximal to the joint and volar contact distal to the joint. This is a similar design to the original Stack splint, except that it is custom molded.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
Exclusion Criteria
* an intra-articular fragment of the distal phalanx involved greater than one third of articular surface
* DIP joint subluxation
* pre-existing arthritis of the DIP joint was present
18 Years
65 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Canadian Orthopaedic Foundation
OTHER
St. Paul's Hospital, Canada
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
St Paul's Hospital
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Jeffrey M Pike, MD
Role: PRINCIPAL_INVESTIGATOR
St. Paul's Hospital
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
St Paul's Hospital
Vancouver, British Columbia, Canada
Countries
Review the countries where the study has at least one active or historical site.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
H05-50193
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.