Foam Mask - Assessment of Bioburden in a New Mask Seal Material
NCT ID: NCT00773721
Last Updated: 2021-02-04
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
NA
20 participants
INTERVENTIONAL
2008-10-31
2009-05-31
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
A key contributor to comfort is the seal component of the mask system. Current mask seals are mainly silicone elastomers, which though well understood and accepted, are often uncomfortable. It is proposed to replace the solid elastomer with a soft polymer foam.
The foam is highly porous, and has open cells at its surface. It is therefore more likely to accumulate biological material with repeated use. The current (silicone) material does not present any problematic bioburden issues. Therefore it is important to investigate whether the foam will present bioburden problems to patients, within specified usage parameters.
The aims of this study therefore are:
1. to observe the rate of bacterial accumulation on foam mask seal material (polyether polyurethane,)
2. to determine the replacement interval for a foam mask seal, and
3. assess the comfort and function of a foam mask seal.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
The Evaluation of a Mask Seal/Mask for the Treatment of Obstructive Sleep Apnea (OSA)
NCT03092921
The Evaluation of a Nasal Mask for the Treatment of Obstructive Sleep Apnea (OSA)
NCT02730273
Analysis of a New Mask for Positive Airway Pressure (PAP) Device Users
NCT01847846
Assessment of the Performance of a New Reduced Noise Mask Vent
NCT01575210
The Evaluation of an Alternative Sizing Model in Comparison of a Conventional Sizing Model for Full Face Masks in the Treatment of OSA in Terms of Performance and Comfort
NCT02851628
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Subjects will wear the test unit mask, instead of the current CPAP mask, each night whilst sleeping. Upon waking, subjects will remove the test unit mask and place it with the skin contact side uppermost on a flat surface adjacent to their bed (e.g. a bedside table). Test unit masks should not be covered, and are to remain exposed to the bedroom environment for the rest of the day. The cycle repeats for up to 35 days (5 weeks).
If necessary, the test can be terminated before this time.
A control group of 2 subjects will wash their test unit mask with only hot water every day for the 5 weeks. Another 4 subjects will have the foam of their test unit mask replaced during the 5 weeks of the trial. Two subjects will have the foam changed after 2 weeks and the other 2 subjects after 4 weeks. This will allow estimations of bioburden after 1,2,3,4 and 5 weeks of use.
The foam samples are to be sealed in the supplied sterile container. The sealed container will be delivered as soon as possible to the project administrator. The project administrator will appropriately collect, record, store, and dispatch the sealed samples for microbiological analysis.
Microbial analysis will determine the number of colony forming units, and species present in each test unit upon test termination.
Skin Reactions:
Participants will be asked to report any skin reaction they experience under the test unit. Subjects will keep a bi-weekly record of any skin redness, irritation, etc.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NA
SINGLE_GROUP
TREATMENT
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
1
Volunteers who are currently using CPAP treatment will trial a new mask system for up to five weeks
CPAP mask
Current CPAP masks are mainly silicone elastomers, which though well understood and accepted, are often uncomfortable.
Test Units: The test unit is a foam seal component which directly replaces the patients existing silicone mask cushion, and is fitted to the patients existing mask frame.
Subjects will wear the test unit mask, instead of their current CPAP mask, each night whilst sleeping.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
CPAP mask
Current CPAP masks are mainly silicone elastomers, which though well understood and accepted, are often uncomfortable.
Test Units: The test unit is a foam seal component which directly replaces the patients existing silicone mask cushion, and is fitted to the patients existing mask frame.
Subjects will wear the test unit mask, instead of their current CPAP mask, each night whilst sleeping.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Patients willing to give written informed consent
* Patients who can read and comprehend English
* Patients being treated for OSA with CPAP for \>6 months
* Patients using ResMed Masks
Exclusion Criteria
* Has been treated with antibiotics in the previous month
* Any condition which, in the opinion of the investigator, would make the subject unsuitable or unsafe for enrolment, or could interfere with the subject participating in and completing the protocol.
* Patients currently using ResMed masks: Swift, Activa, or Liberty.
18 Years
80 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
ResMed
INDUSTRY
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Klaus Schindhelm, PhD
Role: PRINCIPAL_INVESTIGATOR
ResMed/ The University of New South Wales
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Resmed Centre for Healthy Sleep
Sydney, New South Wales, Australia
Countries
Review the countries where the study has at least one active or historical site.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
MA131008
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.