EEG, Cerebral Oximetry, and Arterial to Jugular Venous Lactate to Assess Cerebral Ischemia During Carotid Endarterectomy
NCT ID: NCT00737334
Last Updated: 2009-11-11
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
NA
40 participants
INTERVENTIONAL
2008-09-30
2009-10-31
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Enhanced Diagnosis of Ventricular Activation Pattern Using Intracardiac Electrograms
NCT02057588
Postoperative Clinical and Neurophysiological Assessment of Patients After Open Heart Surgery
NCT06707454
Comparison of Two Methods of Strain by Perioperative Transesophageal Echo in CABG : An Observational Study
NCT02692131
An Intracavitary Electrocardiographic System for Real-time Positioning Peripherally Inserted Central Catheter Tip
NCT02409589
Postoperative Acute Myocardial Ischemic Injury
NCT02993263
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
We hypothesize that the EEGo monitor will be able to more accurately indicate if the brain is at risk of ischemia and better able to direct therapy to relieve the ischemic episode as compared to the BIS monitor. The EEGo will be superior because the raw signal is processed using phase delay analysis, with each patient's raw EEG analyzed instead of a proprietary but generic signal processing approach on a linear scale as with the BIS monitor. Phase delay analysis is a standard approach to display nonlinear signals. A highly reproducible signal transition occurs with differing depths of anesthesia. The ability to process the EEG and display phase delay plots in 50 msec is what makes the EEGo monitor attractive to acutely assess changes in the EEG which can manifest with cerebral ischemia. We also hypothesize that the FORE-SIGHT cerebral oximeter will be an effective monitor for detecting cerebral ischemia during CEA. Accurate assessment of changes in the EEG and cerebral tissue oxygen saturation with carotid cross-clamping will allow better anesthesia management of patients undergoing CEA.
This pilot study will be done to assess the ability of the nonlinear EEG monitor (the EEGo) compared to the BIS monitor and the FORE-SIGHT cerebral oximeter to direct therapy if cerebral ischemia occurs -- notifying the surgeon of the findings, optimizing the blood pressure, arterial oxygenation and carbon dioxide tensions, and permitting consideration of placing a carotid shunt. The EEGo processes the standard EEG signal by nonlinear analysis of the raw signal by 3 dimensional phase delay plots. A cascade from a point attractor, periodic attractor, toroidal attractor to a 3D chaotic attractor occurs from burst suppression to the awake state. These resemble phase transitions and occur rapidly from one state to the next. An analogy is the phase transition that occurs when water changes to ice and vice versa. Monitoring these transitions should permit a rational approach to monitoring cerebral well-being during carotid cross-clamping with CEA. The EEGo will be compared directly in real time to the bispectral (BIS) monitor and to the FORE-SIGHT cerebral oximeter for intraoperative monitoring during CEA.
Cerebral oximetry (also known as Near Infrared Spectroscopy or NIRS) provides a non-invasive measure of regional cerebral tissue oxygen saturation which reflects local oxygen supply and demand, and could indicate cerebral ischemia when desaturation occurs. The FORE-SIGHT cerebral oximeter is a non-invasive, optically-based near-infrared spectrometer that continuously estimates absolute cerebral tissue oxygen saturation, and works based on the principal that hemoglobin's two forms -- oxygenated and deoxygenated -- absorb light differently. The sensor projects laser into the brain at four different wavelengths (to maximize accuracy), with the reflected light being analyzed via algorithm to an absolute value of cerebral saturation. The FORE-SIGHT has been validated in several studies that have shown good precision of the cerebral tissue oxygen saturation value.
In addition, as previously stated, the two EEG monitors and FORE-SIGHT cerebral oximeter will be correlated with arterial to jugular venous lactate differences. In a recent paper, arterial to jugular venous lactate differences were shown to be especially sensitive for detecting cerebral ischemia in awake surgery for CEA. In that paper the sensitivity of lactate differences to detect ischemic changes was 100% for a difference greater than 0.1 mmole/L; 100% specificity if the difference exceeded 0.32 mmole/L; and an ROC best fit for a difference greater than 0.16 mmole/L. In this study we plan to look at a combined approach during carotid artery cross-clamping -- measures of lactate differences with simultaneous assessment of cerebral tissue oxygen saturation using the FORE-SIGHT cerebral oximeter, and EEG changes using two different processed EEG monitors (the well established BIS monitor and the newer EEGo monitor). As such, this is intensified monitoring for these patients at risk of cerebral ischemia over the standard of care.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NA
SINGLE_GROUP
DIAGNOSTIC
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
1
All patients will have continuous EEGo, BIS and FORE-SIGHT monitoring, which will be correlated with arterial to jugular venous lactate differences.
EEGo, BIS, FORE-SIGHT cerebral oximeter
The EEGo monitor, BIS monitor, and FORE-SIGHT cerebral oximeter will be used for cerebral monitoring of all patients. A comparison of the three monitors will be done. For EEGo monitoring, five bipolar electrodes will be placed per International 1020 system. For BIS monitoring, the BIS quattro sensor will be placed on the forehead in usual fashion. For FORE-SIGHT monitoring, the two sensor strips will be placed on the forehead in usual fashion.
All patients will have their ipsilateral Internal Jugular vein cannulated by the surgeon intraoperatively with a 16g IV cannula, through which a Portex multi-orifice epidural catheter will then be placed.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
EEGo, BIS, FORE-SIGHT cerebral oximeter
The EEGo monitor, BIS monitor, and FORE-SIGHT cerebral oximeter will be used for cerebral monitoring of all patients. A comparison of the three monitors will be done. For EEGo monitoring, five bipolar electrodes will be placed per International 1020 system. For BIS monitoring, the BIS quattro sensor will be placed on the forehead in usual fashion. For FORE-SIGHT monitoring, the two sensor strips will be placed on the forehead in usual fashion.
All patients will have their ipsilateral Internal Jugular vein cannulated by the surgeon intraoperatively with a 16g IV cannula, through which a Portex multi-orifice epidural catheter will then be placed.
Other Intervention Names
Discover alternative or legacy names that may be used to describe the listed interventions across different sources.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
Exclusion Criteria
* A history of asthma requiring routine use of bronchodilators because the study will use desflurane as the volatile agent
* Pregnancy
* Non-elective carotid endarterectomy
18 Years
85 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
University of Manitoba
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
University of Manitoba
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
W. Alan C. Mutch, MD
Role: PRINCIPAL_INVESTIGATOR
University of Manitoba
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Health Sciences Centre
Winnipeg, Manitoba, Canada
Countries
Review the countries where the study has at least one active or historical site.
References
Explore related publications, articles, or registry entries linked to this study.
Espenell AE, McIntyre IW, Gulati H, Girling LG, Wilkinson MF, Silvaggio JA, Koulack J, West M, Harding GE, Kaufmann AM, Mutch WA. Lactate flux during carotid endarterectomy under general anesthesia: correlation with various point-of-care monitors. Can J Anaesth. 2010 Oct;57(10):903-12. doi: 10.1007/s12630-010-9356-7. Epub 2010 Jul 27.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
B2008:095
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.