The ENDEAVOR IV Clinical Trial: A Trial of a Coronary Stent System in Coronary Artery Lesions
NCT ID: NCT00217269
Last Updated: 2012-04-20
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
NA
1548 participants
INTERVENTIONAL
2005-04-30
2011-07-31
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
The Medtronic Endeavor III Drug Eluting Coronary Stent System Clinical Trial
NCT00217256
The ENDEAVOR II Clinical Trial: The Medtronic Endeavor Drug Eluting Coronary Stent System in Coronary Artery Lesions
NCT00614848
The ENDEAVOR Pharmacokinetic (PK) Registry: The Medtronic Endeavor Drug Eluting Coronary Stent System
NCT00314275
The Medtronic RESOLUTE Clinical Trial
NCT00248079
Endeavor Zotarolimus - Eluting Stent in the Treatment Lesions in Small Native Coronary Arteries.
NCT00609947
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
RANDOMIZED
PARALLEL
TREATMENT
TRIPLE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
1
Endeavor Drug Eluting Stent
Coronary Artery Stenting
Endeavor Drug eluting stent
2
Taxus Drug Eluting Stent
Coronary Artery Stenting
Taxus Drug Eluting Stent
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Coronary Artery Stenting
Endeavor Drug eluting stent
Coronary Artery Stenting
Taxus Drug Eluting Stent
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* The patient is an acceptable candidate for percutaneous transluminal coronary angioplasty (PTCA), stenting, and emergent coronary artery bypass graft (CABG) surgery.
* Female patients of childbearing potential must have a negative pregnancy test within 7 days before the procedure.
* The patient or patient's legal representative has been informed of the nature of the study and agrees to its provisions and has provided written informed consent as approved by the Institutional Review Board/Ethics Committee (IRB/EC) of the respective clinical site.
* The patient agrees to return to the same research facility for all required post-procedure follow-up visits.
Exclusion Criteria
* History of an allergic reaction or significant sensitivity to drugs such as ABT-578, rapamycin, tacrolimus, everolimus, or any other analogue or derivative.
* History of an allergic reaction or significant sensitivity to paclitaxel or drugs in similar class.
* A platelet count \< 100,000 cells/mm³ or \> 700,000 cells/mm³, or a white blood cell (WBC) count \< 3,000 cells/mm³.
* A serum creatinine level \> 2.0 mg/dl within seven days prior to index procedure.
* Evidence of an acute MI within 72 hours of the intended index procedure (defined as: QWMI or non-Q wave myocardial infarction (NQWMI) having CK enzymes \> 2X the upper laboratory normal with the presence of a CK-MB elevated above the Institution's upper limit of normal).
* Previous PCI of the target vessel within 9 months pre-procedure.
* Planned PCI of any vessel within 30 days post-procedure.
* During the index procedure, the target lesion requires treatment with a device other than PTCA prior to stent placement (including but not limited to, cutting balloon, any atherectomy, any laser, thrombectomy, etc.).
* History of a stroke or transient ischemic attack (TIA) within the prior 6 months.
* Active peptic ulcer or upper gastrointestinal (GI) bleeding within the prior 6 months.
* History of bleeding diathesis or coagulopathy or will refuse blood transfusions.
* Concurrent medical condition with a life expectancy of less than 12 months.
* Any previous or planned treatment of the target vessel with anti-restenotic therapies including, but not limited to brachytherapy.
* Currently participating in an investigational drug or another device study that has not completed the primary endpoint or that clinically interferes with the current study endpoints; or requires coronary angiography, IVUS or other coronary artery imaging procedures.
* Documented left ventricular ejection fraction (LVEF) \< 30% at most recent evaluation.
18 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Medtronic Vascular
INDUSTRY
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Martin B. Leon, M.D.
Role: PRINCIPAL_INVESTIGATOR
Columbia University College of Physicians & Surgeons
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
New York-Presbyterian Hospital/Columbia University Medical Center
New York, New York, United States
Countries
Review the countries where the study has at least one active or historical site.
References
Explore related publications, articles, or registry entries linked to this study.
Kirtane AJ, Leon MB, Ball MW, Bajwa HS, Sketch MH Jr, Coleman PS, Stoler RC, Papadakos S, Cutlip DE, Mauri L, Kandzari DE; ENDEAVOR IV Investigators. The "final" 5-year follow-up from the ENDEAVOR IV trial comparing a zotarolimus-eluting stent with a paclitaxel-eluting stent. JACC Cardiovasc Interv. 2013 Apr;6(4):325-33. doi: 10.1016/j.jcin.2012.12.123. Epub 2013 Mar 20.
Mauri L, Massaro JM, Jiang S, Meredith I, Wijns W, Fajadet J, Kandzari DE, Leon MB, Cutlip DE, Thompson KP. Long-term clinical outcomes with zotarolimus-eluting versus bare-metal coronary stents. JACC Cardiovasc Interv. 2010 Dec;3(12):1240-9. doi: 10.1016/j.jcin.2010.08.021.
Leon MB, Nikolsky E, Cutlip DE, Mauri L, Liberman H, Wilson H, Patterson J, Moses J, Kandzari DE; ENDEAVOR IV Investigators. Improved late clinical safety with zotarolimus-eluting stents compared with paclitaxel-eluting stents in patients with de novo coronary lesions: 3-year follow-up from the ENDEAVOR IV (Randomized Comparison of Zotarolimus- and Paclitaxel-Eluting Stents in Patients With Coronary Artery Disease) trial. JACC Cardiovasc Interv. 2010 Oct;3(10):1043-50. doi: 10.1016/j.jcin.2010.07.008.
Leon MB, Mauri L, Popma JJ, Cutlip DE, Nikolsky E, O'Shaughnessy C, Overlie PA, McLaurin BT, Solomon SL, Douglas JS Jr, Ball MW, Caputo RP, Jain A, Tolleson TR, Reen BM 3rd, Kirtane AJ, Fitzgerald PJ, Thompson K, Kandzari DE; ENDEAVOR IV Investigators. A randomized comparison of the Endeavor zotarolimus-eluting stent versus the TAXUS paclitaxel-eluting stent in de novo native coronary lesions 12-month outcomes from the ENDEAVOR IV trial. J Am Coll Cardiol. 2010 Feb 9;55(6):543-54. doi: 10.1016/j.jacc.2009.08.067.
Remak E, Manson S, Hutton J, Brasseur P, Olivier E, Gershlick A. Cost-effectiveness of the Endeavor stent in de novo native coronary artery lesions updated with contemporary data. EuroIntervention. 2010 Feb;5(7):826-32. doi: 10.4244/eijv5i7a138.
Leon MB, Kandzari DE, Eisenstein EL, Anstrom KJ, Mauri L, Cutlip DE, Nikolsky E, O'Shaughnessy C, Overlie PA, Kirtane AJ, McLaurin BT, Solomon SL, Douglas JS Jr, Popma JJ; ENDEAVOR IV Investigators. Late safety, efficacy, and cost-effectiveness of a zotarolimus-eluting stent compared with a paclitaxel-eluting stent in patients with de novo coronary lesions: 2-year follow-up from the ENDEAVOR IV trial (Randomized, Controlled Trial of the Medtronic Endeavor Drug [ABT-578] Eluting Coronary Stent System Versus the Taxus Paclitaxel-Eluting Coronary Stent System in De Novo Native Coronary Artery Lesions). JACC Cardiovasc Interv. 2009 Dec;2(12):1208-18. doi: 10.1016/j.jcin.2009.10.008.
Waseda K, Miyazawa A, Ako J, Hasegawa T, Tsujino I, Sakurai R, Yock PG, Honda Y, Kandzari DE, Leon MB, Fitzgerald PJ; ENDEAVOR IV Trial Investigators. Intravascular ultrasound results from the ENDEAVOR IV trial: randomized comparison between zotarolimus- and paclitaxel-eluting stents in patients with coronary artery disease. JACC Cardiovasc Interv. 2009 Aug;2(8):779-84. doi: 10.1016/j.jcin.2009.05.015.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
IP060
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.