European Study of the BrioVAD Heart Pump for Advanced Heart Failure

NCT ID: NCT07252531

Last Updated: 2025-11-26

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

NOT_YET_RECRUITING

Clinical Phase

NA

Total Enrollment

60 participants

Study Classification

INTERVENTIONAL

Study Start Date

2026-04-15

Study Completion Date

2029-01-31

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

This clinical investigation evaluates the safety and clinical performance of the BrioVAD Left Ventricular Assist System in patients with advanced, refractory left ventricular heart failure who require mechanical circulatory support.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

This clinical investigation is conducted to assess the clinical performance and safety of the BrioVAD Left Ventricular Assist System (BrioVAD System) when used for mechanical circulatory support in patients with advanced, refractory left ventricular heart failure.

The BrioVAD System is a fully magnetically levitated, centrifugal-flow left ventricular assist device (LVAD) intended to provide short-term and long-term mechanical circulatory support (MCS) in patients with advanced, refractory heart failure who remain symptomatic despite optimal medical and device therapy. The BrioVAD System is intended for use both inside and outside the hospital environment.

This investigation is designed as a prospective, multi-centre, single-arm, non-inferiority clinical investigation. The performance of the BrioVAD System will be evaluated against a pre-defined Objective Performance Goal (OPG) based on contemporary LVAD clinical outcomes.

The primary objective is to demonstrate that the BrioVAD System provides non-inferior clinical benefit, as measured by survival free from device replacement/removal due to device malfunction at 6 months post-implant, compared with the OPG.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Refractory Heart Failure Cardiovascular Diseases (CVD)

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

NA

Intervention Model

SINGLE_GROUP

Primary Study Purpose

TREATMENT

Blinding Strategy

NONE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Treatment group

Group Type EXPERIMENTAL

LVAD implantation

Intervention Type DEVICE

Implantation of an LVAD in the chest

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

LVAD implantation

Implantation of an LVAD in the chest

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

1. Patient is ≥ 18 years of age.
2. Patient has a body surface area (BSA) ≥ 1.2 m2.
3. Patient is classified as NYHA Class IV with advanced heart failure refractory to advanced heart failure management or NYHA Class III with dyspnea upon mild physical activity.
4. Patient has a left ventricular ejection fraction (LVEF) ≤ 25% or LVEF \< 30% on inotropes or temporary mechanical circulatory support (MCS).
5. Patient is inotrope dependent, OR has a cardiac index (CI) ≤ 2.2 liters/min/m2, while not on inotropes, and also meets one of the following criteria:

1. Is on optimal medical management (OMM), based on current heart failure practice guidelines for at least 45 out of the last 60 days and is failing to respond or is not able to tolerate OMM; or
2. Has advanced heart failure for at least 14 days and is dependent on an intra-aortic balloon pump (IABP) or temporary mechanical circulatory support device (MCSD) for at least seven days.
6. Patient has provided voluntary and informed consent.
7. Females of childbearing age agree to use adequate contraception and have a negative pregnancy test.

Exclusion Criteria

1. Patient's heart failure etiology is related to restrictive or constrictive physiology (e.g., nondilated hypertrophic cardiomyopathy, cardiac amyloidosis/senile or other infiltrative disease), complex congenital heart disease (e.g., transposition of the great vessels), uncorrected thyroid disease, and/or pericardial disease.
2. Patient had a myocardial infarction within seven days of study enrollment.
3. Patient had cardiothoracic surgery within 30 days of implant with the exception of a procedure to implant temporary MCS: Impella 5.5, Impella CP, or TandemHeart.
4. Patient has physiological conditions or comorbidities which pose high surgical risk or obstacles as determined by the Investigator.
5. Patient has contraindications to warfarin anticoagulation.
6. Patient has known hypo- or hypercoagulable state \[e.g., disseminated intravascular coagulation (DIC)\], or has a positive heparin-induced thrombocytopenia (HIT) assay and positive serotonin release assay or requires use of a non-heparin alternative anticoagulation strategy for cardiopulmonary bypass in the judgement of the Investigator.
7. Patient is on durable MCS (e.g., LVAD or RVAD).
8. Planned need for durable or temporary RVAD support concomitant with LVAD implant.
9. Patient is on any form of pre-implant temporary MCS other than isolated LVAD support with an intra-aortic balloon pump, Impella 5.5, Impella CP, or TandemHeart.
10. Patient is on any form of pre-implant temporary MCS with a serum lactate dehydrogenase greater than 2.5 times the upper limits of normal or with plasma free hemoglobin \> 40 g/dL.
11. Patient has a history of organ transplantation.
12. Patient has a mechanical aortic valve that may not be converted to a bioprosthetic valve at the time of VAD implant.
13. Patient has a platelet count \< 50 k/µl.
14. Patient has a history of confirmed untreated abdominal aortic aneurysm (AAA) \> 5 cm in diameter.
15. Patient has moderate or severe aortic insufficiency that will not be corrected during the VAD implant procedure.
16. Patient has an uncontrolled systemic infection.
17. Patient has a positive COVID 19 test within 21 days of study enrollment and at least one high risk feature including need for supplemental oxygen or ferritin \>1000 ug/L.
18. Patient has severe end-organ dysfunction as evidenced by one or more of the following criteria:

1. Total bilirubin \> 3.0 mg/dL or cirrhosis confirmed by liver imaging or hemodynamic assessment with or without biopsy confirmation.
2. International normalized ratio (INR) ≥ 2.0 or PTT \> 2.5 times control that is not related to anticoagulation therapy.
3. Glomerular filtration rate (GFR) \< 30 mL/ min/1.73 m2 or need for renal replacement therapy.
4. Severe pulmonary arterial hypertension with a pulmonary vascular resistance (PVR) ≥ 8 Wood units that is not acutely reversible with pharmacologic intervention.
5. Severe chronic obstructive pulmonary disease (COPD) or restrictive lung disease requiring home oxygen or an FEV1/FVC \< 0.7 and FEV1 \< 40% predicted.
6. Mechanical ventilation for more than three days present at the time of study enrollment.
7. Documented history of pulmonary embolism or pulmonary infarct within 60 days of study enrollment.
8. History of stroke within 90 days of study enrollment or history of stroke with a mRS ≥ 3 at the time of study enrollment.
9. Symptomatic cerebrovascular disease and/or uncorrected carotid stenosis \> 80%.
10. Significant peripheral vascular disease (PVD) accompanied by pain at rest or extremity ulceration.
11. Pre-albumin \< 15 mg/dL and/or albumin \< 2.5 g/dL.
19. Patient has a non-cardiac comorbidity or illness that would limit survival to less than two years.
20. Patient has a psychiatric disease or disorder, or irreversible cognitive dysfunction, and/or insufficient social support or a history of non-adherence with medical instructions that is likely to impair study compliance.
21. Patient is participating in an interventional clinical trial that may impact or confound the results of the BrioVAD Trial.
Minimum Eligible Age

18 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Meditrial SrL

INDUSTRY

Sponsor Role collaborator

BrioHealth BV

INDUSTRY

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Responsibility Role SPONSOR

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

DOC-04930

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

Multidisciplinary Ventricular Assist Device Clinic
NCT05388019 ENROLLING_BY_INVITATION NA
Pacing in Heart Failure With Preserved LVEF
NCT03215849 ENROLLING_BY_INVITATION NA