TEAVR With False Lumen Embolization for Aortic Dissection

NCT ID: NCT07198295

Last Updated: 2025-09-30

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

NOT_YET_RECRUITING

Total Enrollment

72 participants

Study Classification

OBSERVATIONAL

Study Start Date

2025-10-01

Study Completion Date

2029-12-31

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

This multicenter, prospective, observational study aims to evaluate the efficacy and safety of thoracic endovascular aortic repair (TEVAR) combined with false lumen embolization using vascular plugs in patients with acute type B aortic dissection. Despite TEVAR being a standard treatment for type B dissection, long-term outcomes remain suboptimal due to persistent false lumen perfusion through distal re-entry tears, leading to aortic expansion and high reintervention rates. This study addresses the clinical need for a more definitive treatment strategy that promotes complete false lumen thrombosis and aortic remodeling.

The study plans to enroll 72 subjects across multiple centers in China, with each participant followed for 12 months. Key inclusion criteria comprise patients with acute or subacute (≤30 days from onset) type B aortic dissection exhibiting typical symptoms and extending to the infrarenal aorta, who are scheduled for the combined procedure. Exclusion criteria included those requiring emergency surgery, complicated dissections with malperfusion or rupture, trauma-related or infectious etiologies, prior aortic surgery, uncontrolled systemic diseases, recent myocardial infarction or stroke, and patients outside the 18-80 age range or refusing participation.

The primary efficacy endpoint is the complete thrombosis rate of the false lumen in the thoracic aorta at 12 months postoperatively, while the primary safety endpoint is the incidence of major adverse events (MAEs) at the same time point. MAEs are defined as a composite of all-cause mortality, myocardial infarction, respiratory failure requiring prolonged ventilation or reintubation, renal deterioration (\>50% reduction in eGFR or new dialysis), bowel ischemia requiring surgery or refractory to medical therapy, major stroke, and grade 3 paraplegia. Secondary endpoints include thrombosis rates at 1 and 6 months in the thoracic aorta, patency and thrombosis status at the celiac trunk and infrarenal aortic levels at 1, 6, and 12 months, incidence of MAEs at earlier timepoints, and rates of endoleaks and reinterventions.

All subjects will receive a standardized treatment protocol involving TEVAR with stent-graft placement to seal the proximal entry tear, followed by selective catheterization of the false lumen and deployment of 1-3 vascular plugs at predetermined locations: one parallel to the distal edge of the thoracic stent-graft, one at the level of the celiac trunk, and one at the distal re-entry tear in the infrarenal aorta. Follow-up assessments are scheduled at 1, 6, and 12 months post-procedure, including clinical evaluation and thoracoabdominal CTA imaging to assess aortic remodeling and complication status.

This investigation represents the first prospective multicenter effort to evaluate the combined TEVAR and false lumen embolization strategy. By addressing the fundamental limitation of conventional TEVAR-incomplete false lumen exclusion-this study may establish a new standard for achieving complete aortic remodeling in type B dissection. The results are anticipated to provide robust evidence for guiding clinical practice and potentially influencing future treatment guidelines in aortic disease management.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Aortic Dissection Type B

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Observational Model Type

COHORT

Study Time Perspective

PROSPECTIVE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Group 1: TEVAR with false lumen embolization

Patients with type B aortic dissection who receive TEAVR in the true lumen and vascular plug embolization in the false lumen

TEAVR with false lumen embolization

Intervention Type DEVICE

The procedure involves two key steps: first, deploying a stent-graft in the true lumen to seal the proximal entry tear; second, selectively catheterizing the false lumen to place 1-3 vascular plugs at critical locations-below the distal end of the stent-graft, at the celiac trunk level, and at the distal re-entry tear in the infrarenal aorta-to occlude distal outflow and induce complete false lumen thrombosis.

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

TEAVR with false lumen embolization

The procedure involves two key steps: first, deploying a stent-graft in the true lumen to seal the proximal entry tear; second, selectively catheterizing the false lumen to place 1-3 vascular plugs at critical locations-below the distal end of the stent-graft, at the celiac trunk level, and at the distal re-entry tear in the infrarenal aorta-to occlude distal outflow and induce complete false lumen thrombosis.

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

Patients must meet all of the following conditions to be enrolled:

1. Diagnosed with acute or subacute (symptom onset ≤30 days) Stanford type B aortic dissection.
2. Present with typical clinical symptoms and imaging-confirmed aortic dissection.
3. Dissection extends distally to involve the infrarenal abdominal aorta.
4. Scheduled to undergo elective TEVAR combined with false lumen embolization.

Exclusion Criteria

Patients will be excluded if they meet any of the following conditions:

1. Requiring emergency surgery due to rupture, impending rupture, or severe malperfusion.
2. Complicated type B dissection (e.g., visceral/limb ischemia, refractory pain, or hemodynamic instability).
3. Suspected traumatic or infectious etiology of the dissection.
4. Previous history of aortic surgery or endovascular repair.
5. Use of alternative techniques during the procedure (e.g., PETTICOAT, long-segment coverage).
6. Uncontrolled systemic diseases (e.g., severe cardiac/pulmonary/hepatic dysfunction, advanced malignancy, cachexia, or uncorrectable coagulation disorders).
7. Myocardial infarction or stroke within the past 6 months.
8. Age \<18 years or \>80 years.
9. Patient refusal to participate in the study.
Minimum Eligible Age

18 Years

Maximum Eligible Age

80 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

First Affiliated Hospital of Zhejiang University

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Hongkun Zhang, MD

Director of the Department of Vascular Surgery

Responsibility Role PRINCIPAL_INVESTIGATOR

Central Contacts

Reach out to these primary contacts for questions about participation or study logistics.

Hongkun Zhang, M.D.

Role: CONTACT

0086-0571-87236745

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

IIT20250894B

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

VARC-TAVI VALVE IMPLANTATION)
NCT06177392 NOT_YET_RECRUITING NA