Novel Balloon-Assisted vs Direct Technique in EUS-Guided Gastroenterostomy
NCT ID: NCT07161856
Last Updated: 2025-09-09
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
NOT_YET_RECRUITING
NA
272 participants
INTERVENTIONAL
2025-09-01
2026-08-01
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Endoscopic ultrasound-guided gastroenterostomy (EUS-GE) is a minimally invasive technique in which a gastric-jejunal anastomosis is created under real-time EUS guidance, bypassing the obstructed segment and establishing a gastrojejunal shortcut. Compared with conventional surgery or endoscopic luminal stenting, EUS-GE offers reduced procedural trauma and lower recurrence rates, providing GOO patients with an additional, less-invasive therapeutic option.
Three main EUS-GE approaches have been described: the direct method, the balloon-assisted method, and the double-balloon-assisted method. The direct method requires large volumes of water instillation, posing hemodynamic risks in patients with cardiovascular or cerebrovascular disease. The double-balloon technique relies on expensive, specialized devices that have not yet been widely adopted. The conventional balloon-assisted method demands needle puncture of a partially inflated balloon, which compromises stability and can displace the target jejunum away from the gastric wall. All three techniques are technically demanding, limiting their broad clinical dissemination.
The investigators therefore designed and previously reported a dedicated single-balloon-assisted device specifically for EUS-GE. This novel system aims to shorten procedure time, reduce intraprocedural water volume, and enhance procedural safety. The present prospective, multicenter, randomized controlled trial was undertaken to validate the clinical efficacy and safety of this new single-balloon-assisted technique compared with the conventional direct water-injection method.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Comparison of Channel Esophagogastrostomy and Double Tract Reconstruction After Laparoscopic-assist Proximal Gastrectomy: a Propensity Score-Matched Analysis
NCT06741124
Intracorporeal Versus Extracorporeal Roux-en-Y Esophagojejunostomy During Laparoscopic Total Gastrectomy for Gastric Cancer
NCT02085031
Management of Symptomatic Gastric Sleeve Stenosis After Laparoscopic Sleeve Gastrectomy
NCT04781946
A Study Comparing Billroth II With Roux-en-Y Reconstruction for Gastric Cancer
NCT01257711
Impact of Roux-En-Y Pouch Reconstruction Compared With Conventional Roux-En-Y Reconstruction on Quality of Life in Patients Undergoing Total Gastrectomy
NCT01697943
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
RANDOMIZED
PARALLEL
TREATMENT
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
direct EUS-GE
The patients will receive EUS-DGE under general anesthesia with endotracheal intubation. Under direct visualization with a gastroscope, a guidewire and/or nasobiliary catheter is passed through the stricture into the jejunum. A mixture of contrast medium and methylene blue is injected to distend the target intestinal loop. An echoendoscope is introduced into the stomach to select the optimal puncture site.
A 19G or 22G puncture needle is used to puncture the gastric and jejunal walls. Aspiration of fluid confirms the needle tip is in the jejunum, after which the channel is dilated over the guidewire. Using the delivery system of an electrocautery-enhanced fully covered lumen-apposing metal stent (LAMS), the stent is deployed to complete the gastrojejunostomy.
direct EUS-GE
The patients will receive EUS-DGE under general anesthesia with endotracheal intubation. Under direct visualization with a gastroscope, a guidewire and/or nasobiliary catheter is passed through the stricture into the jejunum. A mixture of contrast medium and methylene blue is injected to distend the target intestinal loop. An echoendoscope is introduced into the stomach to select the optimal puncture site.
A 19G or 22G puncture needle is used to puncture the gastric and jejunal walls. Aspiration of fluid confirms the needle tip is in the jejunum, after which the channel is dilated over the guidewire. Using the delivery system of an electrocautery-enhanced fully covered lumen-apposing metal stent (LAMS), the stent is deployed to complete the gastrojejunostomy.
a novel balloon-assisted EUS-GE
The patients will receive EUS-NBAGE under general anesthesia with endotracheal intubation. Under direct visualization with a gastroscope, contrast medium is injected to determine the location and length of the stricture. A guidewire is then placed through the stricture into the jejunum, approximately 15 cm distal to the anal side of the stricture. A double-balloon device is inserted over the guidewire. The anal-side balloon is inflated with about 40 mL of air, and under fluoroscopy, the balloon is confirmed to be well inflated. A mixture of contrast medium and methylene blue in a 1:1 dilution is injected into the proximal small intestine through the water injection channel at the proximal end of the catheter. A linear echoendoscope is inserted into the mid-body of the stomach on the greater curvature side to scan the distended small intestine loop. After identifying the distended small intestine loop, a HOT-AXIOS 1.5×1.0cm LAMS is placed under direct visualization.
a novel balloon-assisted EUS-GE
The patients will receive EUS-NBAGE under general anesthesia with endotracheal intubation. Under direct visualization with a gastroscope, contrast medium is injected to determine the location and length of the stricture. A guidewire is then placed through the stricture into the jejunum, approximately 15 cm distal to the anal side of the stricture. A double-balloon device is inserted over the guidewire. The anal-side balloon is inflated with about 40 mL of air, and under fluoroscopy, the balloon is confirmed to be well inflated. A mixture of contrast medium and methylene blue in a 1:1 dilution is injected into the proximal small intestine through the water injection channel at the proximal end of the catheter. A linear echoendoscope is inserted into the mid-body of the stomach on the greater curvature side to scan the distended small intestine loop. After identifying the distended small intestine loop, a HOT-AXIOS 1.5×1.0cm LAMS is placed under direct visualization.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
a novel balloon-assisted EUS-GE
The patients will receive EUS-NBAGE under general anesthesia with endotracheal intubation. Under direct visualization with a gastroscope, contrast medium is injected to determine the location and length of the stricture. A guidewire is then placed through the stricture into the jejunum, approximately 15 cm distal to the anal side of the stricture. A double-balloon device is inserted over the guidewire. The anal-side balloon is inflated with about 40 mL of air, and under fluoroscopy, the balloon is confirmed to be well inflated. A mixture of contrast medium and methylene blue in a 1:1 dilution is injected into the proximal small intestine through the water injection channel at the proximal end of the catheter. A linear echoendoscope is inserted into the mid-body of the stomach on the greater curvature side to scan the distended small intestine loop. After identifying the distended small intestine loop, a HOT-AXIOS 1.5×1.0cm LAMS is placed under direct visualization.
direct EUS-GE
The patients will receive EUS-DGE under general anesthesia with endotracheal intubation. Under direct visualization with a gastroscope, a guidewire and/or nasobiliary catheter is passed through the stricture into the jejunum. A mixture of contrast medium and methylene blue is injected to distend the target intestinal loop. An echoendoscope is introduced into the stomach to select the optimal puncture site.
A 19G or 22G puncture needle is used to puncture the gastric and jejunal walls. Aspiration of fluid confirms the needle tip is in the jejunum, after which the channel is dilated over the guidewire. Using the delivery system of an electrocautery-enhanced fully covered lumen-apposing metal stent (LAMS), the stent is deployed to complete the gastrojejunostomy.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* GOO patients caused by all reasons (including benign diseases such as ulcers or malignant tumors)
* Not suitable for or cannot tolerate surgical operations and endoscopic intestinal stent implantation
* There are no absolute contraindications for EUS-GE
* Signed informed consents
Exclusion Criteria
* Unable or refused to provide informed consents
* Patients with cognitive impairment, aphasia, mental disorders, or other conditions that may affect the patient's cooperation
* Patients with endoscopic contraindications, anesthesia contraindications, digestive tract perforation or abdominal cavity infection
* The tumor invades the duodenum or the upper segment of the jejunum Individuals whom the investigator deems unsuitable for participation
18 Years
80 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Changhai Hospital
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
CHEC2025-284
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.