Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

RECRUITING

Total Enrollment

590 participants

Study Classification

OBSERVATIONAL

Study Start Date

2025-11-04

Study Completion Date

2027-08-02

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

This study aims to improve the early detection of undiagnosed heart disease, which causes serious health issues, hospital admissions, and high healthcare costs. Researchers are exploring how artificial intelligence (AI) can analyse routine heart tests, called electrocardiograms (ECGs), to detect heart problems. These tests can be done using both traditional ECG machines and portable, wearable devices like smartwatches, making it easier for people to monitor their heart health at home.

While AI has shown promise using past data, this study will involve the collection of ECG data and subsequent testing of its accuracy in real-world settings to ensure it works well for both doctors and patients. The goal is to see if AI can identify conditions like heart muscle weakness, valve issues, and high lung pressure from the ECG data of patients. The researchers will also compare AI's detections with other blood tests commonly used to diagnose heart disease.

The AI models that will be used are being tested for research and validation purposes only. They will not be used for clinical decision-making or providing information to influence diagnosis, treatment, or patient care during the study. The AI outputs are not shared with clinicians and will have no impact on the care pathway.

This research will demonstrate if AI-powered ECG analysis - whether from traditional or portable devices - can provide a low-cost, non-invasive way to detect heart disease early and improve health assessments.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Valvular Heart Disease Stenosis and Regurgitation (Diagnosis) Pulmonary Hypertension (Diagnosis) Heart Failure With Reduced Ejection Fraction (HFrEF; Diagnosis) Heart Failure With Preserved Ejection Fraction (HFpEF; Diagnosis)

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Observational Model Type

COHORT

Study Time Perspective

PROSPECTIVE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Echocardiography cohort

This cohort of patients will be attending for inpatient and outpatient transthoracic echocardiograms (TTEs) as part of their routine clinical care, having been referred by clinicians for various standard TTE indications, including investigation of symptoms such as breathlessness due to possible heart failure (HF), and screening for suspected valvular heart disease (VHD) and/or pulmonary hypertension (PH). These patients will have had no prior formal diagnosis of HF, VHD, and/or PH.

Traditional 12-lead Electrocardiogram

Intervention Type OTHER

12-lead ECG investigation is a standard, non-invasive diagnostic procedure used as an intervention to assess participants' cardiac electrical activity. For the purposes of this study, 12-lead ECGs will be collected for the application of AI-ECG models for the detection of HF, VHD, and/or PH and will not be used to inform or alter patients' standard NHS care.

Apple Watch Series 4 Single-lead Electrocardiogram

Intervention Type OTHER

Single-lead ECG taken using an Apple Watch Series 4 is a non-invasive, participant-initiated recording of cardiac electrical activity through a wearable device. While more limited than a 12-lead ECG, it can capture rhythm abnormalities-such as atrial fibrillation-and offers a convenient method for remote or continuous heart monitoring during the study. For the purposes of this study, single-lead ECGs will be collected for the application of AI-ECG models for the detection of HF, VHD, and/or PH and will not be used to inform or alter patients' standard NHS care.

Eko Core 500 Digital Stethoscope 3-lead Electrocardiogram

Intervention Type OTHER

Three-lead ECG recorded using the Eko CORE 500 digital stethoscope is a non-invasive, clinician-operated cardiac assessment tool that captures real-time electrical activity of the heart during auscultation. It provides enhanced diagnostic information compared to single-lead recordings, allowing detection of arrhythmias and signs of structural heart disease at the point of care, supporting integrated clinical and digital assessment. For the purposes of this study, 3-lead ECGs will be collected for the application of AI-ECG models for the detection of HF, VHD, and/or PH and will not be used to inform or alter patients' standard NHS care.

AliveCor KardiaMobile Single- and 6-lead Electrocardiogram

Intervention Type OTHER

A single- or 6-lead ECG recorded using the AliveCor KardiaMobile 6L device which is a portable, non-invasive method for capturing cardiac electrical activity. Operated by the participant or clinician, the device enables rapid rhythm assessment and detection of abnormalities such as atrial fibrillation. The 6-lead configuration offers more comprehensive data than single-lead recordings, supporting enhanced arrhythmia and conduction analysis in both in-clinic and remote settings. For the purposes of this study, single- and 6-lead ECGs will be collected for the application of AI-ECG models for the detection of HF, VHD, and/or PH and will not be used to inform or alter patients' standard NHS care.

N-terminal pro B-type natriuretic peptide subgroup

A subgroup of 203 patients, out of the total 590 patiets in the Echocardiography cohort, will be randomised to undergo blood tests and collection of serum N-terminal pro B-type natriuretic peptide (NT-proBNP).

Traditional 12-lead Electrocardiogram

Intervention Type OTHER

12-lead ECG investigation is a standard, non-invasive diagnostic procedure used as an intervention to assess participants' cardiac electrical activity. For the purposes of this study, 12-lead ECGs will be collected for the application of AI-ECG models for the detection of HF, VHD, and/or PH and will not be used to inform or alter patients' standard NHS care.

Apple Watch Series 4 Single-lead Electrocardiogram

Intervention Type OTHER

Single-lead ECG taken using an Apple Watch Series 4 is a non-invasive, participant-initiated recording of cardiac electrical activity through a wearable device. While more limited than a 12-lead ECG, it can capture rhythm abnormalities-such as atrial fibrillation-and offers a convenient method for remote or continuous heart monitoring during the study. For the purposes of this study, single-lead ECGs will be collected for the application of AI-ECG models for the detection of HF, VHD, and/or PH and will not be used to inform or alter patients' standard NHS care.

Eko Core 500 Digital Stethoscope 3-lead Electrocardiogram

Intervention Type OTHER

Three-lead ECG recorded using the Eko CORE 500 digital stethoscope is a non-invasive, clinician-operated cardiac assessment tool that captures real-time electrical activity of the heart during auscultation. It provides enhanced diagnostic information compared to single-lead recordings, allowing detection of arrhythmias and signs of structural heart disease at the point of care, supporting integrated clinical and digital assessment. For the purposes of this study, 3-lead ECGs will be collected for the application of AI-ECG models for the detection of HF, VHD, and/or PH and will not be used to inform or alter patients' standard NHS care.

AliveCor KardiaMobile Single- and 6-lead Electrocardiogram

Intervention Type OTHER

A single- or 6-lead ECG recorded using the AliveCor KardiaMobile 6L device which is a portable, non-invasive method for capturing cardiac electrical activity. Operated by the participant or clinician, the device enables rapid rhythm assessment and detection of abnormalities such as atrial fibrillation. The 6-lead configuration offers more comprehensive data than single-lead recordings, supporting enhanced arrhythmia and conduction analysis in both in-clinic and remote settings. For the purposes of this study, single- and 6-lead ECGs will be collected for the application of AI-ECG models for the detection of HF, VHD, and/or PH and will not be used to inform or alter patients' standard NHS care.

Phlebotomy for N-terminal pro-B-type natriuretic peptide

Intervention Type OTHER

A minimally invasive biomarker assessment used to evaluate cardiac wall stress and function. Elevated levels can indicate the presence or severity of heart failure and other forms of structural heart disease, making it a valuable tool for diagnosis, risk stratification, and monitoring of cardiac status throughout the study period. For the purposes of this study, NT-proBNP will be collected to assess its accuracy at detecting HF, PH, and VHD with comparison with AI-ECG detections. The investigators will also evaluate the accuracy of AI-ECG detections combined with NT-pro-BNP, for detecting HF, VHD, and PH. The investigators will not be using NT-proBNP results to inform or alter patients' standard NHS care.

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Traditional 12-lead Electrocardiogram

12-lead ECG investigation is a standard, non-invasive diagnostic procedure used as an intervention to assess participants' cardiac electrical activity. For the purposes of this study, 12-lead ECGs will be collected for the application of AI-ECG models for the detection of HF, VHD, and/or PH and will not be used to inform or alter patients' standard NHS care.

Intervention Type OTHER

Apple Watch Series 4 Single-lead Electrocardiogram

Single-lead ECG taken using an Apple Watch Series 4 is a non-invasive, participant-initiated recording of cardiac electrical activity through a wearable device. While more limited than a 12-lead ECG, it can capture rhythm abnormalities-such as atrial fibrillation-and offers a convenient method for remote or continuous heart monitoring during the study. For the purposes of this study, single-lead ECGs will be collected for the application of AI-ECG models for the detection of HF, VHD, and/or PH and will not be used to inform or alter patients' standard NHS care.

Intervention Type OTHER

Eko Core 500 Digital Stethoscope 3-lead Electrocardiogram

Three-lead ECG recorded using the Eko CORE 500 digital stethoscope is a non-invasive, clinician-operated cardiac assessment tool that captures real-time electrical activity of the heart during auscultation. It provides enhanced diagnostic information compared to single-lead recordings, allowing detection of arrhythmias and signs of structural heart disease at the point of care, supporting integrated clinical and digital assessment. For the purposes of this study, 3-lead ECGs will be collected for the application of AI-ECG models for the detection of HF, VHD, and/or PH and will not be used to inform or alter patients' standard NHS care.

Intervention Type OTHER

AliveCor KardiaMobile Single- and 6-lead Electrocardiogram

A single- or 6-lead ECG recorded using the AliveCor KardiaMobile 6L device which is a portable, non-invasive method for capturing cardiac electrical activity. Operated by the participant or clinician, the device enables rapid rhythm assessment and detection of abnormalities such as atrial fibrillation. The 6-lead configuration offers more comprehensive data than single-lead recordings, supporting enhanced arrhythmia and conduction analysis in both in-clinic and remote settings. For the purposes of this study, single- and 6-lead ECGs will be collected for the application of AI-ECG models for the detection of HF, VHD, and/or PH and will not be used to inform or alter patients' standard NHS care.

Intervention Type OTHER

Phlebotomy for N-terminal pro-B-type natriuretic peptide

A minimally invasive biomarker assessment used to evaluate cardiac wall stress and function. Elevated levels can indicate the presence or severity of heart failure and other forms of structural heart disease, making it a valuable tool for diagnosis, risk stratification, and monitoring of cardiac status throughout the study period. For the purposes of this study, NT-proBNP will be collected to assess its accuracy at detecting HF, PH, and VHD with comparison with AI-ECG detections. The investigators will also evaluate the accuracy of AI-ECG detections combined with NT-pro-BNP, for detecting HF, VHD, and PH. The investigators will not be using NT-proBNP results to inform or alter patients' standard NHS care.

Intervention Type OTHER

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Patients aged 18-90 years
* No prior formal diagnosis of HF (including systolic and diastolic dysfunction), PH, or VHD
* Ability to provide informed consent

Exclusion Criteria

* Severe arrhythmia or unstable cardiovascular disease
* Prior formal diagnosis of HF (including systolic and diastolic dysfunction), PH, or VHD
* Cardiac implantable electronic device in-situ, including a permanent pacemaker or implantable cardioverter defibrillator
* Involvement in current research or recent involvement in any research prior to recruitment
Minimum Eligible Age

18 Years

Maximum Eligible Age

90 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

Yes

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Imperial College London

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Responsibility Role SPONSOR

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Chelsea and Westminster Hospital

London, , United Kingdom

Site Status RECRUITING

West Middlesex University Hospital

London, , United Kingdom

Site Status RECRUITING

Countries

Review the countries where the study has at least one active or historical site.

United Kingdom

Central Contacts

Reach out to these primary contacts for questions about participation or study logistics.

Ahmed YM El-Medany, MBChB, MRCP, MSc, FHEA

Role: CONTACT

+44 02075943614

Facility Contacts

Find local site contact details for specific facilities participating in the trial.

Ahmed YM El-Medany, MBChB, MRCP, MSc, FHEA

Role: primary

+44 02075943614

Ahmed YM El-Medany, MBChB, MRCP, MSc, FHEA

Role: primary

+44 02075943614

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

179372

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

HeartGuide: Preliminary Study
NCT05490303 UNKNOWN NA