Extracellular Vesicle Surface Markers In Acute Cerebrovascular Syndromes.
NCT ID: NCT06319742
Last Updated: 2024-04-18
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
RECRUITING
200 participants
OBSERVATIONAL
2022-11-18
2026-01-31
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Transient Ischemic Attacks (TIAs) represent a classical example for which a biomarker would be of interest to confirm and distinguish a brain ischemic process from a stroke mimic. Diagnostic biomarkers of TIA have been investigated, but none of the potential candidates reached enough accuracy for TIA diagnosis. Our group has found that Extracellular Vesicles (EVs) could be useful as biomarkers for detecting brain ischemia in patients with TIA because the EV-surface antigen profile appears to be different in patients with transient symptoms, adjudicated to be very likely caused by brain ischemia, compared to patients whose symptoms were less likely to due to brain ischemia. Our study has raised interest in the scientific community recognizing the promising role of of blood-derived EVs analysis in expanding the possibilities to correctly diagnose and classify TIA and stroke events, discriminate them from TIA or stroke mimics, with important future implications in management and therapy of the patients with acute ischemic cerebrovascular syndrome. the validity of our approach needs to be tested in a larger, prospective, multicenter study.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Blood Extracellular Vesicles as Predictive Recovery Biomarker After Stroke and Brain Injury
NCT06871800
Extracellular Vesicles as Stroke Biomarkers
NCT05370105
Prognosis of Cerebral Small Vessel Disease
NCT05734378
Glymphatic Function and White Matter Integrity in Cerebral Venous Disorders
NCT07072663
Reperfusion Injury After Endovascular Stroke Treatment
NCT05273216
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
We will evaluate diameter and concentration of serum nanoparticles (NPs) by nanoparticle tracking analysis (NTA) using NanoSight LM10 (Malvern Instruments, United Kingdom) equipped with a 405 nm laser and Nanoparticle Tracking Analysis NTA 2.3 analytic software. A camera will record Brownian movement of EVs and size and number of EVs per mL will be calculated by Stokes-Einstein equation. Three videos of 60 s will be recorded for each analysis.
Western Blot analysis will be performed on protein lysate after EV immuno-capture (using beads covered with antibodies against EV specific tetraspanins, CD9, CD63 and CD81). Blots of representative samples will be incubated with primary antibodies against specific markers expressed on the surface or within EVs (TSG101, Syntenin-1, CD81, Alix) and potential contaminants (GRP94, Apolipoprotein A1, Apolipoprotein B48).
EV profiling will be performed using a standardized multiplex bead-based flow cytometric assay, using MACSPlex Human Exosome Kit (Miltenyi Biotec; Bergisch Gladbach, Germany), as previously described. 22 The detection of 37 different surface antigens commonly expressed on EV membrane (including markers from activated platelets, endothelium, and inflammatory cells) will be simultaneously performed. Background will be subtracted from the MFI value of each marker, and then normalized using by the mean fluorescence intensity levels (MFI) of CD9, CD63, and CD81. Levels of expression will be reported as normalized MFI (nMFI; %) for each EV-surface antigen (median value and interquartile range).
After an initial screening by multiplexed assay, single candidate EV biomarkers will be confirmed by either reverse flow cytometry and ELISA techniques.
The reverse flow cytometric assay will be performed by isolating EVs by capture beads coated with antibodies against CD9-CD63-CD81 (EpCam; JSR Micro) and then incubated with fluorochrome-conjugated antibodies against single EV surface antigens, associated to patient diagnosis during the initial screening by MACSPlex assay. Beads incubated with isotype-matched antibodies, and beads incubated in absence of vesicles will serve as controls. Candidate EV biomarkers will be confirmed also by ELISA technique, using specific antibodies as per manufacturer's instructions.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
COHORT
PROSPECTIVE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Stroke
Extracellular vescicles (EV) analysis
The patients undergo a blood sample for EV analyses: EVs will be characterized by nanoparticle tracking analysis, western blot, bead-based flow cytometry (direct and inverse approach), and ELISA.
We will evaluate diameter and concentration of serum nanoparticles (NPs) by nanoparticle tracking analysis (NTA) using NanoSight LM10. Western Blot analysis will be performed on protein lysate after EV immuno-capture (using beads covered with antibodies against EV specific tetraspanins, CD9, CD63 and CD81). EV profiling will be performed using a standardized multiplex bead-based flow cytometric assay, using MACSPlex Human Exosome Kit (Miltenyi Biotec; Bergisch Gladbach, Germany), as previously described. 22 The detection of 37 different surface antigens commonly expressed on EV membrane (including markers from activated platelets, endothelium, and inflammatory cells) will be simultaneously performed.
TIA
Extracellular vescicles (EV) analysis
The patients undergo a blood sample for EV analyses: EVs will be characterized by nanoparticle tracking analysis, western blot, bead-based flow cytometry (direct and inverse approach), and ELISA.
We will evaluate diameter and concentration of serum nanoparticles (NPs) by nanoparticle tracking analysis (NTA) using NanoSight LM10. Western Blot analysis will be performed on protein lysate after EV immuno-capture (using beads covered with antibodies against EV specific tetraspanins, CD9, CD63 and CD81). EV profiling will be performed using a standardized multiplex bead-based flow cytometric assay, using MACSPlex Human Exosome Kit (Miltenyi Biotec; Bergisch Gladbach, Germany), as previously described. 22 The detection of 37 different surface antigens commonly expressed on EV membrane (including markers from activated platelets, endothelium, and inflammatory cells) will be simultaneously performed.
Stroke Mimic
Extracellular vescicles (EV) analysis
The patients undergo a blood sample for EV analyses: EVs will be characterized by nanoparticle tracking analysis, western blot, bead-based flow cytometry (direct and inverse approach), and ELISA.
We will evaluate diameter and concentration of serum nanoparticles (NPs) by nanoparticle tracking analysis (NTA) using NanoSight LM10. Western Blot analysis will be performed on protein lysate after EV immuno-capture (using beads covered with antibodies against EV specific tetraspanins, CD9, CD63 and CD81). EV profiling will be performed using a standardized multiplex bead-based flow cytometric assay, using MACSPlex Human Exosome Kit (Miltenyi Biotec; Bergisch Gladbach, Germany), as previously described. 22 The detection of 37 different surface antigens commonly expressed on EV membrane (including markers from activated platelets, endothelium, and inflammatory cells) will be simultaneously performed.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Extracellular vescicles (EV) analysis
The patients undergo a blood sample for EV analyses: EVs will be characterized by nanoparticle tracking analysis, western blot, bead-based flow cytometry (direct and inverse approach), and ELISA.
We will evaluate diameter and concentration of serum nanoparticles (NPs) by nanoparticle tracking analysis (NTA) using NanoSight LM10. Western Blot analysis will be performed on protein lysate after EV immuno-capture (using beads covered with antibodies against EV specific tetraspanins, CD9, CD63 and CD81). EV profiling will be performed using a standardized multiplex bead-based flow cytometric assay, using MACSPlex Human Exosome Kit (Miltenyi Biotec; Bergisch Gladbach, Germany), as previously described. 22 The detection of 37 different surface antigens commonly expressed on EV membrane (including markers from activated platelets, endothelium, and inflammatory cells) will be simultaneously performed.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
I. Suspect ischemic minor stroke (acute loss of focal cerebral function of presumed vascular etiology and NIHSS ≤327, 28) within 48 hours of symptoms onset or II. TIA (defined as the acute onset of focal neurological symptoms lasting \<24 h and presumed to be caused by brain ischemia at the time of referral)19 III. Symptoms mimicking I. or II. with but with high suspition of a non-ischemic condition being the cause of the event;
2\) age ≥18 years; 3) if cerebral magnetic resonance imaging will be performed within 48-72 hours from admission; 4) if baseline CT/MRI is without hemorrhage; 5) if informed consent obtained.
Exclusion Criteria
2. contraindications for MRI;
3. pregnancy;
4. concomitant acute/chronic inflammatory disease (e.g., infections, autoimmune disease);
5. concomitant hematological diseases;
6. Central Nervous System infection within 30 days;
7. serious head trauma within 30 days;
8. major surgery within 90 days.
18 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Ospedale Civico, Lugano
OTHER_GOV
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Dr. med. Carlo Cereda
Prof. Dr. med.
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Neurocenter of Southern Switzerland, Ospedale Civico
Lugano, Canton Ticino, Switzerland
Countries
Review the countries where the study has at least one active or historical site.
Central Contacts
Reach out to these primary contacts for questions about participation or study logistics.
Facility Contacts
Find local site contact details for specific facilities participating in the trial.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
NSISTRCR_2201
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.