Comparison of Absorbance Values, Sensory Evaluations and Periodontal Effects of Five Different Products for Clean Aligners Cleansing

NCT ID: NCT06278116

Last Updated: 2024-07-10

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Clinical Phase

NA

Total Enrollment

20 participants

Study Classification

INTERVENTIONAL

Study Start Date

2024-03-01

Study Completion Date

2024-06-10

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

The aim of the study is to evaluate the most efficient product for the cleaning of Invisalign® clear aligners (Align Technology Inc., San Jose, CA, USA) through objective and subjective assessments after the use of 5 different products. For each aligner, one product is used for 2 weeks until all of them are used, therefore 5 different aligners are required for the study. A periodontal evaluation is conducted to assess variations during the time frame of the study.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

This randomized clinical trial aims to evaluate the efficacy of 5 different products for the cleansing of Invisalign® clear aligners among the followings:

1. drinking water;
2. dish soap Svelto (Unilever Italia Mkt operations S.r.l.; Roma, IT);
3. Polident Antibacterial Denture Cleaner (GlaxoSmithKline; Philadelphia, Pa, USA);
4. Cleaning Crystals Invisalign® (Align Technology, Inc.; San Jose, CA, USA);
5. Geldis (Kalipharm S.r.l., Alba, IT).

Patients that will sign the informed consent will be enrolled for the study; parents will sign the consent for underage patients.

2 week before the beginning of the orthodontic treatment with Invisalign clear aligners, a professional manual and mechanical removal of supragingival and subgingival deposits of both arches will be performed. At the baseline (T0), the first aligner will be delivered to the patient, that must wear it for 22/24 h except for meals and oral hygiene procedures. One of the 5 cleaning product will be randomly assigned to the patient and toothbrush with silicone bristles (Kalipharm S.r.l., Alba, IT) will be given the cleaning procedures. Patients will be asked to fill in a questionnaire for the subjective appreciation on the cleaning material: the questionnaire presents 19 items evaluating organoleptic and visual characteristics of the aligners and the ease of use of the cleaning method after the first use, after 1 and after 2 weeks. After 2 weeks (T1), patient will be visited again: the questionnaire will be collected, together with the aligner, and a periodontal evaluation on the Ramfjiord teeth will be performed using the following indices: Plaque Index (PI), Bleeding on Probing (BoP), Probing Pocket Depth (PPD), (Gingival Index), BEWE (Basic Erosive Wear Examination), Schiff Air Index. After that, another questionnaire and the following aligner will be given to the patient, another cleaning product will be randomly assigned and another toothbrush will be given. The procedure will be repeated for the following 2 (T2), 4 (T3), 6 (T4) and 8 weeks (T5) until all the cleaning products are tested. All the products will be masked.

JASCO V-750 spectrophotometer (Jasco Corporation, Tokyo, Japan) will be used to evaluate adsorbance for each aligner after the application of the cleaning products. A control value will be calculated using a new clean aligner. The spectrophotometer calculates reflectance values that will be converted in adsorbance values.

Sample size

Sample size was calculated with the following assumptions: ability to detect a clinically relevant difference of 0.0265 in the adsorbance of the clear aligner (primary outcome) of the five groups with an alfa = 0.05 and power = 80%. The assumptions were based on findings of a previous study, with an expected value of 0.190 and a standard deviation of 0.03 for the first group after 2 weeks. Therefore, 20 aligners per each cleaning method were required for the study.

Statistical analysis Statistical analysis will be conducted with R software (R version 3.1.3, R Development Core Team, R Foundation for Statistical Computing, Wien, Austria).

For each variable, Significance for all statistical tests will be predetermined at P\<0.05.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Dental Malocclusion

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

RANDOMIZED

Intervention Model

CROSSOVER

Primary Study Purpose

BASIC_SCIENCE

Blinding Strategy

TRIPLE

Participants Caregivers Outcome Assessors

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Water

Group Type ACTIVE_COMPARATOR

Aligners cleansing with water

Intervention Type OTHER

The product is masked in a spraying bottle without any labels. Once a day, for 14 days, the patient sprays the product on the aligner before cleaning it with a soft bristle toothbrush for 1 minute. Afterward, the aligner is rinsed under fresh running water.

Dish soap

Group Type ACTIVE_COMPARATOR

Aligners cleansing with dish soap Svelto

Intervention Type OTHER

the product is masked in a transparent bottle without any labels. Once a day, for 14 days, the patient puts the product on the aligner before cleaning it with a soft bristle toothbrush for 1 minute. Afterward, the aligner is rinsed under fresh running water.

Polident Antibacterial Denture Cleaner®

Group Type ACTIVE_COMPARATOR

Aligners cleansing with Polident Antibacterial Denture Cleaner

Intervention Type OTHER

the product is masked by deleting all labels on the packaging with a black permanent marker. Once a day, for 14 days, the patient dissolves the tablet in a glass full of warm water (30-35 °C), then the aligner is placed inside it for 5 minutes. Afterward the aligner is rinsed under fresh running water.

Invisalign Cleaning Crystals®

Group Type ACTIVE_COMPARATOR

Aligners cleansing with Invisalign Cleaning Crystals

Intervention Type OTHER

the product is masked by deleting all labels on the packaging with a black permanent marker. Once a day, for 14 days, the patient dissolves the crystals in a glass full of warm water (30-35 °C) mixing with a spoon for 20 seconds; then, the aligner is placed inside the glass for 15 minutes. Afterward, the aligner is rinsed under fresh running water.

Geldis®

Group Type ACTIVE_COMPARATOR

Aligners cleansing with Geldis

Intervention Type OTHER

the product is masked by deleting all labels on the packaging with a black permanent marker. Once a day, for 14 days, the patient puts the product on the aligner before cleaning it with a soft toothbrush for 1 minute. Afterward, the aligner is rinsed under fresh running water.

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Aligners cleansing with water

The product is masked in a spraying bottle without any labels. Once a day, for 14 days, the patient sprays the product on the aligner before cleaning it with a soft bristle toothbrush for 1 minute. Afterward, the aligner is rinsed under fresh running water.

Intervention Type OTHER

Aligners cleansing with dish soap Svelto

the product is masked in a transparent bottle without any labels. Once a day, for 14 days, the patient puts the product on the aligner before cleaning it with a soft bristle toothbrush for 1 minute. Afterward, the aligner is rinsed under fresh running water.

Intervention Type OTHER

Aligners cleansing with Polident Antibacterial Denture Cleaner

the product is masked by deleting all labels on the packaging with a black permanent marker. Once a day, for 14 days, the patient dissolves the tablet in a glass full of warm water (30-35 °C), then the aligner is placed inside it for 5 minutes. Afterward the aligner is rinsed under fresh running water.

Intervention Type OTHER

Aligners cleansing with Invisalign Cleaning Crystals

the product is masked by deleting all labels on the packaging with a black permanent marker. Once a day, for 14 days, the patient dissolves the crystals in a glass full of warm water (30-35 °C) mixing with a spoon for 20 seconds; then, the aligner is placed inside the glass for 15 minutes. Afterward, the aligner is rinsed under fresh running water.

Intervention Type OTHER

Aligners cleansing with Geldis

the product is masked by deleting all labels on the packaging with a black permanent marker. Once a day, for 14 days, the patient puts the product on the aligner before cleaning it with a soft toothbrush for 1 minute. Afterward, the aligner is rinsed under fresh running water.

Intervention Type OTHER

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Patients undergoing orthodontic treatment with Invisalign® clear aligners.

Exclusion Criteria

* Failing to follow cleaning method instructions
* Failing to fill in the questionnaires
Minimum Eligible Age

14 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

Yes

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

University of Pavia

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Andrea Scribante

Associate Professor, Principal Investigator

Responsibility Role PRINCIPAL_INVESTIGATOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Andrea Scribante, DDS, PhD

Role: PRINCIPAL_INVESTIGATOR

University of Pavia

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Unit of Orthodontics and Pediatric Dentistry - Section of Dentistry - Department of Clinical, Surgical, Diagnostic and Pediatrics - University of Pavia

Pavia, Lombardy, Italy

Site Status

Countries

Review the countries where the study has at least one active or historical site.

Italy

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

2024-ALIGNERSCLEANSIGN

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.