PET/MRI of Primary Sclerosing Cholangitis

NCT ID: NCT06252610

Last Updated: 2025-10-16

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

NOT_YET_RECRUITING

Total Enrollment

10 participants

Study Classification

OBSERVATIONAL

Study Start Date

2026-05-10

Study Completion Date

2029-04-30

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

This study aims to use positron emission tomography (PET)/magnetic resonance imaging (MRI) to diagnose and quantify PSC-related biliary tract fibrosis and to improve upon the currently available non-invasive diagnostic capabilities by investigating the ability of combined PET/MRI to detect and quantify fibrosis using a novel collagen-binding radiotracer. Specifically, the investigators will be comparing \[68Ga\]CBP8- and \[18F\]-FAPI-74 PET/MRI to a liver transient elastography scan in the diagnosis of biliary tree fibrosis.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Imaging in the form of cholangiography plays an essential role in diagnosing and managing PSC. In the past decade, magnetic resonance cholangiopancreatography (MRCP) has become preferred over endoscopic retrograde cholangiopancreatography (ERCP) for the diagnosis of PSC because it is non-invasive, thereby safer, and cheaper than ERCP. MRCP's sensitivity and specificity for diagnosing PSC are high, 86% and 94%, respectively. However, to quantify liver fibrosis, MRCP is only accurate in more advanced stages of the disease. Intrahepatic biliary stricture severity was a poor discriminator between the different grades of liver fibrosis measured on magnetic resonance elastography and the different risk strata according to the Mayo Risk Score and The Amsterdam-Oxford prognostic index (AOPI). Other non-invasive diagnostic tests, such as transient elastography, lack full-organ evaluation and may be subject to variation between measurements, despite being the current gold standard for non-invasive fibrosis quantification.

This study aims to use \[68Ga\]CBP8- or \[18F\]FAPI PET/MRI to diagnose and quantify PSC-related biliary tract fibrosis. The novel radiopharmaceutical collagen-binding probe 8 labeled with Gallium-68 selectively binds to collagen type I, the predominant extracellular protein in fibrosis. \[68Ga\]CBP8 has already been investigated in patients affected by pulmonary fibrosis with success. Fibroblast activation protein (FAP) is a type II transmembrane serine protease that is overexpressed in CAFs and, to a lesser extent, in benign processes. It is associated with extracellular matrix remodeling, for example, chronic inflammation, degenerative bone and spine disease, arthritis, and cardiac remodelling after myocardial infarction. Quinolone-based FAP inhibitors (FAPIs) constitute a class of molecules with high affinity to FAP deployed to assess many types of solid tumors and some benign pathologies. 68Ga-FAPIs and, to a lesser extent, 18F-FAPI are being extensively studied in oncologic and non-oncologic positron emission tomography/computed tomography (PET/CT) and, to a lesser extent, PET/MRI, both in Europe and Asia.

In this open-label, single-arm, single-center prospective study, the investigators will recruit 10 patients with known primary sclerosing cholangitis (PSC) who have previously undergone other modalities for the evaluation of hepatic fibrosis, such as liver biopsy and/or transient elastography (FibroScan) and/or MR liver elastography and/or US liver elastography.No healthy volunteers will be included. Patients will be referred to \[68Ga\]CBP8 or \[18F\]-FAPI-74 PET/MRI by their primary treating physicians (e.g., hepatologist). After a phone-call pre-screening, electronic medical records verification, and a screening visit, subjects will be imaged with \[68Ga\]CBP8 or \[18F\]-FAPI-74 PET/MRI. A blood draw might also be performed to measure serum biomarkers of liver fibrosis.

Transient liver elastography has a diagnostic accuracy ranging from 65% in the initial stages to 90% for severe fibrosis in the setting of PSC. There is no data regarding the use of \[68Ga\]CBP8 PET/MRI to diagnose or quantify fibrosis in PSC. Therefore, the investigators lack sufficient evidence to estimate power with a reasonable degree of certainty. By enrolling 10 patients for this initial pilot study in the evaluation of hepatic/biliary fibrosis with \[68Ga\]CBP8 PET/MRI, the investigators will be able to acquire enough data to determine the optimal sample size for a larger study. A paired McNemar's test will be used for hypothesis testing regarding differences in sensitivity, specificity, accuracy, negative predictive value, and positive predictive value between \[68Ga\]CBP8 PET/MRI and FibroScan. Moreover, the investigators will analyze quantitative features of PET (SUV) and obtain their correlation to the actual fibrosis as reported by the gold standard test. These will be performed using Spearman's correlation coefficient and regression analysis.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

PSC

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Observational Model Type

COHORT

Study Time Perspective

PROSPECTIVE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

PSC

Population will be consecutive patients with PSC, who will be referred to us by the MGB-affiliated hepatologists.

Radiotracer Injection

Intervention Type DRUG

An intravenous catheter will be placed in an arm or hand vein for injection of \[68Ga\]CBP8;

* 6-10 mCi of \[68Ga\]CBP8 or 5-9 mCi of FAPI will be injected into the Biograph mMR system. The injected dose and the time of injection will be recorded;
* The catheter will be flushed with 0.9% saline solution;
* The subjects will then be positioned on the scanner table; support devices under the back or legs will be used to enable the patient to maintain his/her position throughout the scan comfortably.

Contrast Media, Magnetic Resonance

Intervention Type DRUG

The same intravenous catheter used to inject the radiotracer will be used to inject the hepatospecific gadolinium contrast agent Eovist (Bayer, Whippany, NJ);

* After being positioned on the PET/MRI table, the nuclear medicine technologist will connect the patient to the MRI-safe power injector;
* The catheter will be flushed before and after injection with 0.9% saline solution;
* About halfway through the imaging session, the study staff will inform the patient that they are going to be administering the contrast agent and what sensations they should and should not expect;
* The contrast will then be injected.

Imaging

Intervention Type DIAGNOSTIC_TEST

MRI and PET scanner to be used:

3.0 T Laboratory (Bay 7) Siemens Biograph mMR.

Magnetic resonance images of the abdomen will be acquired using the Martinos Center's combined 3 Tesla PET/MRI scanner. The image quality on these 3 Tesla devices will be very high, equivalent to or better than any other standard clinical MRI system. PET images of the target body site will be acquired When necessary, the data acquisition will be started shortly before radiotracer injection; Coincidence event data will be acquired and stored in list mode or compressed (i.e., sinogram space) format. Subjects will be asked to lie still for the duration of the study. The entire imaging session will last up to 120 minutes

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Radiotracer Injection

An intravenous catheter will be placed in an arm or hand vein for injection of \[68Ga\]CBP8;

* 6-10 mCi of \[68Ga\]CBP8 or 5-9 mCi of FAPI will be injected into the Biograph mMR system. The injected dose and the time of injection will be recorded;
* The catheter will be flushed with 0.9% saline solution;
* The subjects will then be positioned on the scanner table; support devices under the back or legs will be used to enable the patient to maintain his/her position throughout the scan comfortably.

Intervention Type DRUG

Contrast Media, Magnetic Resonance

The same intravenous catheter used to inject the radiotracer will be used to inject the hepatospecific gadolinium contrast agent Eovist (Bayer, Whippany, NJ);

* After being positioned on the PET/MRI table, the nuclear medicine technologist will connect the patient to the MRI-safe power injector;
* The catheter will be flushed before and after injection with 0.9% saline solution;
* About halfway through the imaging session, the study staff will inform the patient that they are going to be administering the contrast agent and what sensations they should and should not expect;
* The contrast will then be injected.

Intervention Type DRUG

Imaging

MRI and PET scanner to be used:

3.0 T Laboratory (Bay 7) Siemens Biograph mMR.

Magnetic resonance images of the abdomen will be acquired using the Martinos Center's combined 3 Tesla PET/MRI scanner. The image quality on these 3 Tesla devices will be very high, equivalent to or better than any other standard clinical MRI system. PET images of the target body site will be acquired When necessary, the data acquisition will be started shortly before radiotracer injection; Coincidence event data will be acquired and stored in list mode or compressed (i.e., sinogram space) format. Subjects will be asked to lie still for the duration of the study. The entire imaging session will last up to 120 minutes

Intervention Type DIAGNOSTIC_TEST

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Established clinical diagnosis of large duct PSC
* Participants receiving treatment for IBD are allowed if on a stable dose from screening and expected to remain stable for the duration of the study
* Serum AST and ALT concentration ≤ 8 times the upper limit of normal

Exclusion Criteria

* Other causes of chronic liver disease, including secondary sclerosing cholangitis or viral, metabolic, or alcoholic liver disease, as assessed clinically
* Known or suspected overlapping clinical or histologic diagnosis of autoimmune hepatitis
* Subjects less than 18 years of age or greater than 85 years of age.
* Subjects with electrical implants, such as cardiac pacemakers or perfusion pumps.
* Subjects with ferromagnetic implants such as aneurysm clips, surgical clips, prostheses, artificial hearts, prosthetic heart valves that are not compatible with the gradient maps of our scanners, metal fragments, shrapnel, metallic tattoos anywhere on the body, tattoos near the eye, or steel implants ferromagnetic objects such as jewelry or metal clips in clothing.
* Subjects who anticipate being pregnant or breastfeeding (a negative STAT quantitative serum hCG pregnancy test is required on the day of the scan before the subject can participate).
* Subjects with claustrophobic reactions
* Subjects with more significant than average potential for cardiac arrest.
* Subjects with a history of major head trauma (i.e., multiple concussions, traumatic brain injury).
* Subjects with a history of bleeding disorders.
* Subjects whose research-related radiation exposure exceeds current Radiology Department guidelines (i.e., 50 mSv in the prior 12 months).
* Subjects unable to lie comfortably on a bed inside the PET/MRI bore as assessed by physical examination and medical history (e.g., back pain, arthritis).
* Subjects under the direct supervision of the principal investigator;
* Subjects with a body weight of \> 300 lbs (operational weight limit of the PET/MRI table) or BMI \>33 kg/m2 (the Athinoula A. Martinos Center standard procedure to avoid claustrophobia or mechanical impossibility of fitting the subject into the scanner bore, which is less than 60 cm wide).
* A history of acute or chronic severe renal insufficiency (glomerular filtration rate \<30 mL/min/1.73m2
* Perioperative liver transplantation period.
* A history of systemic lupus, multiple myeloma, nephrogenic systemic fibrosis, or other comorbidities resulting in chronic kidney disease stage IV or higher
Minimum Eligible Age

18 Years

Maximum Eligible Age

99 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Massachusetts General Hospital

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Onofrio A. Catalano, MD, PhD

MD, Ph.D

Responsibility Role PRINCIPAL_INVESTIGATOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Onofrio Catalano, MD, Ph.D

Role: PRINCIPAL_INVESTIGATOR

Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Harvard Medical School

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Harvard Medical School

Charlestown, Massachusetts, United States

Site Status

Countries

Review the countries where the study has at least one active or historical site.

United States

Central Contacts

Reach out to these primary contacts for questions about participation or study logistics.

Onofrio Catalano, MD, Ph.D

Role: CONTACT

617-724-4030

Diandrea Galloway

Role: CONTACT

617-643-1407

References

Explore related publications, articles, or registry entries linked to this study.

Ludwig J. Surgical pathology of the syndrome of primary sclerosing cholangitis. Am J Surg Pathol. 1989;13 Suppl 1:43-9.

Reference Type BACKGROUND
PMID: 2699167 (View on PubMed)

Lindor KD, Kowdley KV, Harrison ME; American College of Gastroenterology. ACG Clinical Guideline: Primary Sclerosing Cholangitis. Am J Gastroenterol. 2015 May;110(5):646-59; quiz 660. doi: 10.1038/ajg.2015.112. Epub 2015 Apr 14.

Reference Type BACKGROUND
PMID: 25869391 (View on PubMed)

Dave M, Elmunzer BJ, Dwamena BA, Higgins PD. Primary sclerosing cholangitis: meta-analysis of diagnostic performance of MR cholangiopancreatography. Radiology. 2010 Aug;256(2):387-96. doi: 10.1148/radiol.10091953.

Reference Type BACKGROUND
PMID: 20656832 (View on PubMed)

Tafur M, Cheung A, Menezes RJ, Feld J, Janssen H, Hirschfield GM, Jhaveri KS. Risk stratification in primary sclerosing cholangitis: comparison of biliary stricture severity on MRCP versus liver stiffness by MR elastography and vibration-controlled transient elastography. Eur Radiol. 2020 Jul;30(7):3735-3747. doi: 10.1007/s00330-020-06728-6. Epub 2020 Mar 4.

Reference Type BACKGROUND
PMID: 32130494 (View on PubMed)

Vuppalanchi R, Sanyal AJ. Myths and mysteries about staging hepatic fibrosis by fibroscan. Clin Gastroenterol Hepatol. 2015 Apr;13(4):780-2. doi: 10.1016/j.cgh.2014.10.030. Epub 2014 Nov 5. No abstract available.

Reference Type BACKGROUND
PMID: 25451885 (View on PubMed)

Montesi SB, Izquierdo-Garcia D, Desogere P, Abston E, Liang LL, Digumarthy S, Seethamraju R, Lanuti M, Caravan P, Catana C. Type I Collagen-targeted Positron Emission Tomography Imaging in Idiopathic Pulmonary Fibrosis: First-in-Human Studies. Am J Respir Crit Care Med. 2019 Jul 15;200(2):258-261. doi: 10.1164/rccm.201903-0503LE. No abstract available.

Reference Type BACKGROUND
PMID: 31161770 (View on PubMed)

Catalano OA, Gee MS, Nicolai E, Selvaggi F, Pellino G, Cuocolo A, Luongo A, Catalano M, Rosen BR, Gervais D, Vangel MG, Soricelli A, Salvatore M. Evaluation of Quantitative PET/MR Enterography Biomarkers for Discrimination of Inflammatory Strictures from Fibrotic Strictures in Crohn Disease. Radiology. 2016 Mar;278(3):792-800. doi: 10.1148/radiol.2015150566. Epub 2015 Oct 5.

Reference Type BACKGROUND
PMID: 26436860 (View on PubMed)

Catalano OA, Wu V, Mahmood U, Signore A, Vangel M, Soricelli A, Salvatore M, Gervais D, Rosen BR. Diagnostic performance of PET/MR in the evaluation of active inflammation in Crohn disease. Am J Nucl Med Mol Imaging. 2018 Feb 5;8(1):62-69. eCollection 2018.

Reference Type BACKGROUND
PMID: 29531862 (View on PubMed)

Corpechot C, Gaouar F, El Naggar A, Kemgang A, Wendum D, Poupon R, Carrat F, Chazouilleres O. Baseline values and changes in liver stiffness measured by transient elastography are associated with severity of fibrosis and outcomes of patients with primary sclerosing cholangitis. Gastroenterology. 2014 Apr;146(4):970-9; quiz e15-6. doi: 10.1053/j.gastro.2013.12.030. Epub 2013 Dec 31.

Reference Type BACKGROUND
PMID: 24389304 (View on PubMed)

Ehlken H, Wroblewski R, Corpechot C, Arrive L, Rieger T, Hartl J, Lezius S, Hubener P, Schulze K, Zenouzi R, Sebode M, Peiseler M, Denzer UW, Quaas A, Weiler-Normann C, Lohse AW, Chazouilleres O, Schramm C. Validation of Transient Elastography and Comparison with Spleen Length Measurement for Staging of Fibrosis and Clinical Prognosis in Primary Sclerosing Cholangitis. PLoS One. 2016 Oct 10;11(10):e0164224. doi: 10.1371/journal.pone.0164224. eCollection 2016.

Reference Type BACKGROUND
PMID: 27723798 (View on PubMed)

Kratochwil C, Flechsig P, Lindner T, Abderrahim L, Altmann A, Mier W, Adeberg S, Rathke H, Rohrich M, Winter H, Plinkert PK, Marme F, Lang M, Kauczor HU, Jager D, Debus J, Haberkorn U, Giesel FL. 68Ga-FAPI PET/CT: Tracer Uptake in 28 Different Kinds of Cancer. J Nucl Med. 2019 Jun;60(6):801-805. doi: 10.2967/jnumed.119.227967. Epub 2019 Apr 6.

Reference Type BACKGROUND
PMID: 30954939 (View on PubMed)

Altmann A, Haberkorn U, Siveke J. The Latest Developments in Imaging of Fibroblast Activation Protein. J Nucl Med. 2021 Feb;62(2):160-167. doi: 10.2967/jnumed.120.244806. Epub 2020 Oct 30.

Reference Type BACKGROUND
PMID: 33127618 (View on PubMed)

Giesel FL, Adeberg S, Syed M, Lindner T, Jimenez-Franco LD, Mavriopoulou E, Staudinger F, Tonndorf-Martini E, Regnery S, Rieken S, El Shafie R, Rohrich M, Flechsig P, Kluge A, Altmann A, Debus J, Haberkorn U, Kratochwil C. FAPI-74 PET/CT Using Either 18F-AlF or Cold-Kit 68Ga Labeling: Biodistribution, Radiation Dosimetry, and Tumor Delineation in Lung Cancer Patients. J Nucl Med. 2021 Feb;62(2):201-207. doi: 10.2967/jnumed.120.245084. Epub 2020 Jun 26.

Reference Type BACKGROUND
PMID: 32591493 (View on PubMed)

Sanchez-Crespo A. Comparison of Gallium-68 and Fluorine-18 imaging characteristics in positron emission tomography. Appl Radiat Isot. 2013 Jun;76:55-62. doi: 10.1016/j.apradiso.2012.06.034. Epub 2012 Aug 29.

Reference Type BACKGROUND
PMID: 23063597 (View on PubMed)

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

2022P002225

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

PSMA PET and MRI in Gynecological Cancers
NCT03302156 TERMINATED PHASE2
Advanced Imaging for Pulmonary Fibrosis
NCT06532071 RECRUITING PHASE2