An Alternative Technique for Measuring Blood Pressure

NCT ID: NCT06119412

Last Updated: 2024-11-15

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Clinical Phase

NA

Total Enrollment

202 participants

Study Classification

INTERVENTIONAL

Study Start Date

2023-10-20

Study Completion Date

2023-12-01

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

This cross design study will be conducted to evaluate the combination of palpation and auscultation techniques as an alternative technique for the measurement of blood pressure. The main questions it aims to answer are:

* Is there a statistical difference between the results of systolic blood pressure measured with the old and new technique?
* Is there a statistical difference between the results of systolic blood pressure measured with the old and new technique? Participants' blood pressure will be measured twice.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

As a result of clinical observations, a common practice is to inflate the cuff to a high and random mmHg value and start auscultation directly. Alternatively, many healthcare workers determine the moment when pulse beats disappear by palpation and increase this value by 30 mmHg without lowering the cuff and without taking a break for 1-2 minutes and start auscultation. In the literature, there is a similar technique called "one-step method". According to this technique, the sphygmomanometer is wrapped around the individual's arm and the stethoscope is placed in the ear. The brachial artery is then palpated and identified. The cuff is inflated up to 30 mmHg above the systolic blood pressure of the individual. The cuff is then depressurized to 2-3 mmHg/second. It is observed that many healthcare professionals and students use this technique today because it is more practical in terms of measurement time. However, it is thought that the step of "inflating the cuff up to 30 mmHg above the systolic blood pressure value of the individual" in the process steps of the technique is not reliable enough. It is thought that it may lead to erroneous results in capturing sudden blood pressure changes in the individual. In this context, it is thought that it would be more reliable to determine the value at the moment when the pulse is not felt with the palpation technique, add 30 mmHg to this value without interruption and without lowering the cuff and continue auscultation. At the same time, combining palpation and auscultation and continuing them consecutively will shorten the measurement time and provide a practical application.

It is aimed to measure blood pressure in approximately 202 healthy adults. The purpose and method of the study will be explained in detail to all participants included in the sample group. Participants will be allowed to rest for 15-30 minutes before blood pressure measurement. Blood pressure will be measured with two different techniques according to the order in which the participants are included in the study. The first participant's blood pressure will first be measured with the standard technique in the literature (with a break between palpation and auscultation). After a 60-second pause, blood pressure will be measured with the alternative recommended technique (palpation and auscultation combined). In the second participant, blood pressure will be measured first with the alternative recommended technique (combining palpation and auscultation). After a 60-second break and with the arm in the same position, blood pressure will be measured with the standard technique in the literature (with a break between palpation and auscultation). The cross-over method will be applied as possible differences between measurement times should be taken into account.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Healthy

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

RANDOMIZED

Intervention Model

CROSSOVER

Primary Study Purpose

OTHER

Blinding Strategy

SINGLE

Outcome Assessors

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

group 1, starting with standard technique

According to block randomization, the 1st researcher will first apply the standard technique (60 seconds pause between palpation and auscultation), 1 minute break will be given, and the 2nd researcher will apply the alternative new technique (no break between palpation and auscultation) on the same person.

Group Type OTHER

blood pressure measurement starting with standard technique or alternative new technique. manual sphygmomanometer will be used.

Intervention Type OTHER

Each participant will have their blood pressure measured with two different techniques.

group 2, starting with alternative new technique

According to block randomization, Investigator 1 will first apply the alternative new technique (no pause between palpation and auscultation) to the people in the second group, and a 1-minute break will be given. The 2nd researcher will apply the standard technique (60 seconds break between palpation and auscultation) on the same person.

Group Type OTHER

blood pressure measurement starting with standard technique or alternative new technique. manual sphygmomanometer will be used.

Intervention Type OTHER

Each participant will have their blood pressure measured with two different techniques.

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

blood pressure measurement starting with standard technique or alternative new technique. manual sphygmomanometer will be used.

Each participant will have their blood pressure measured with two different techniques.

Intervention Type OTHER

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Over 18 years of age,
* no chronic disease,
* not taking any medication and/or treatment that affects the cardiovascular or circulatory system,
* volunteering to participate in the research.

Exclusion Criteria

* has a chronic disease,
* taking medication that affects the cardiovascular or circulatory system,
* wants to leave the study at any stage.
Minimum Eligible Age

18 Years

Maximum Eligible Age

65 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Gazi University

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Evrim Eyikara

Doctor Research assistant, Principal Investigator

Responsibility Role PRINCIPAL_INVESTIGATOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Evrim Eyikara

Role: PRINCIPAL_INVESTIGATOR

doctor research assistant

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Gazi University Department of Health Sciences

Ankara, , Turkey (Türkiye)

Site Status

Countries

Review the countries where the study has at least one active or historical site.

Turkey (Türkiye)

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

GaziU-SBF-EE-02

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

Hybrid Blood Pressure Monitor Validation
NCT01120990 COMPLETED PHASE4