Impact of Aerosol Box Use During Cardiopulmonary Arrest: A Multicenter Study

NCT ID: NCT05868239

Last Updated: 2025-09-05

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

RECRUITING

Clinical Phase

NA

Total Enrollment

240 participants

Study Classification

INTERVENTIONAL

Study Start Date

2023-09-01

Study Completion Date

2026-12-01

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

Aerosol Generating Medical Procedures (AGMP) are procedures that have the potential to create tiny particles suspended in the air. These particles can contain germs such as viruses. The Coronavirus Disease 2019 (COVID-19) pandemic was caused by the novel severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Patients infected with SARS-CoV-2 experience unusually high rates of critical illness that needs advanced airway management and intensive care unit admission. Bag-valve-mask (BVM) ventilation, endotracheal Intubation (ETI) and chest compressions are sometimes required for critically ill COVID-19 patients, and may contribute to a high risk of infection amongst Health Care Workers (HCW). To lessen HCW risk during high-risk procedures, a device called an aerosol box has been developed to place over the head of the patient, shielding the provider's face from virus droplets suspended in the air.

The purpose of this research study is to better understand how particles disperse during AGMPs, more specifically during the provision of cardiopulmonary resuscitation (CPR). The project team hopes what is learned from the project can help inform infection control measures. This could help make changes to the clinical environment and make it safer for HCW's. The investigators intend to explore how an aerosol box performs in reducing contamination of HCW's who perform critical airway interventions during resuscitation events.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Problem to be addressed. The overwhelming scale and severity of the Coronavirus Disease 2019 (COVID-19) pandemic has presented a serious threat to the health of frontline health care workers (HCWs). Aerosol-generating medical procedures (AGMPs), such as bag-valve-mask (BVM) ventilation, endotracheal intubation (ETI), and cardiopulmonary resuscitation (CPR) are commonly required for critically ill COVID-19 patients. AGMPs produce airborne particles, contributing to the disproportionately high risk of infection amongst HCWs working in acute care areas. Strategies to mitigate HCWs exposure to and infection from COVID-19 are required to maintain the integrity of the healthcare workforce. To minimize HCW exposure during AGMPs, aerosol box devices have been developed to provide a physical barrier between the patient and the HCW, with the intent of shielding HCWs from disease particles.

The aerosol box, and its various different adaptations, have been implemented by hospitals around the world for managing critically ill patients with COVID-19. Studies to date have demonstrated that aerosol box use potentially reduces spread of aerosolized particles, but its use is also associated with technical challenges. Studies to date have focused primarily on the task of ETI, without any evidence describing the impact of aerosol box use on chest compressions (CC). Furthermore, most studies suffer from small sample sizes, provided minimal (or no) training on aerosol box use, recruited individuals (and not resuscitation teams) as participants, failed to quantify the degree of contamination on providers, or failed to measure airborne particle counts. The study team recently completed a multicenter randomized trial comparing aerosol box vs. no box use and demonstrated delayed time to intubation with aerosol box use. However, the study was done in a limited context (short procedure, airway team of 2 providers, CC not measured), thus making generalizability to team-based resuscitative care questionable. To date, there have been no single or multicenter studies concurrently evaluating the effect of aerosol box use on CPR quality, airborne particle concentration, and HCW contamination during team-based resuscitative care. As a consequence, it is still unknown if aerosol boxes are effective in protecting HCWs, and if aerosol box use negatively impacts care during cardiopulmonary arrest.

The importance and relevance of simulation-based aerosolization studies is highly dependent upon the use of a realistic model for aerosolization. Several groups have reported aerosolization devices in the form of cough simulation devices ranging from hand-held syringes, nasal atomizers, spray guns, bag-valve masking and more advanced air flow-based devices to simulate cough. Unfortunately, none of these cough simulators were designed for user-controlled settings of respiratory mechanics (eg. respiratory rate, volume, flow) while also allowing for performance of intubation and chest compressions. This study represents the first aerosol box study to use an aerosolization device comprised of a respiratory simulator allowing for control of respiratory mechanics that closely mimic those of a real patient, while concurrently allowing performance of AGMPs.

Our study will provide evidence to: (a) evaluate if use of an aerosol box adversely affects time to completion and quality of critical resuscitation tasks; and (b) determine if aerosol boxes are effective in reducing airborne particle counts and provider contamination during team-based cardiac arrest resuscitation. Our long-term goal is to provide empiric evidence to enhance HCW safety while delivering high quality care during cardiopulmonary resuscitation. This will be accomplished by creating a cardiac arrest scenario within a controlled simulated clinical environment, as conducting a similar study on real patients would be fraught with challenges and risks.

Why is a trial needed now? New COVID-19 variants, variable uptake of immunizations, and waning immunity amongst the immunized population contribute to the persistent threat of the COVID-19 pandemic. We've learned how quickly the pandemic can change course, and how it is important to plan for future pandemics caused by different viruses. Now, more than ever, it is critical to identify strategies to protect healthcare workers from infection. HCW infection has led to workforce shortages that negatively impact patient outcome. Aerosol boxes have been used in some parts of the world to protect HCWs during the pandemic, but existing evidence gaps have prevented its widespread adoption. A better understanding of particle dispersion patterns, HCW contamination patterns, and impact on clinical task performance during resuscitative care will help to inform international cardiac arrest guidelines.

How will the results of this trial be used? Research assessing strategies to mitigate HCW risks of contamination are critical to maintaining a viable healthcare workforce during the pandemic. The proposed study provides further evidence informing the potential use of aerosol boxes during simulated cardiopulmonary arrest. The research will be the first to provide a quantitative measure of airborne particles and HCW contamination patterns in conjunction with clinically important outcome measures. In combination, these metrics provide key information that will inform clinical practice, institutional airway management and cardiac arrest policies. Through partnerships (e.g. Heart and Stroke Foundation of Canada) and longitudinal engagement of key local and national public health agency stakeholders, the results of this study will be shared with policymakers to enable evidence-based adaptations to clinical protocols. Existing partnerships within the International Network for Simulation-based Pediatric Innovation, Research and Education (INSPIRE network) will enable rapid dissemination of aerosol box training material across all continents if results are positive. As an author on international COVID-19 and cardiac arrest resuscitation guidelines, the PI will engage stakeholders to ensure results inform future International Liaison Committee on Resuscitation (ILCOR) guidelines for or against use of the aerosol box.

Trial design. A prospective, randomized controlled trial will be conducted across five sites in North America. Simulation-based research confers the advantage of answering research questions without risk of harm to HCWs or patients. Three participants will be recruited to play the roles of airway provider, and two CPR providers in the management of a simulated, critically ill COVID-19 patient. CPR providers will be trained to provide CPR coaching to each other. Two trained research assistants will participate in the resuscitation team as a team leader and bedside nurse/airway assistant and perform these roles in a standardized manner. Team leaders will not provide any guidance or coaching on CPR quality. Participants will be randomized by team into either the control arm (i.e. no aerosol box) or the intervention arm (i.e. use of aerosol box) (Figure 1). Following randomization, all participants will view a short video orienting them to the simulated clinical environment. Intervention arm teams will view an additional 5-minute video orienting them to the design of the aerosol box and including expert-modeled demonstration of strategies for optimal airway management and delivery of CPR. This includes how to move the patient within the aerosol box to optimize delivery of CPR. The training video will be filmed in English and French to permit viewing across all study sites. After viewing the video, participants will work in teams to practice intubation and CPR (with aerosol box in place) for a maximum of 15 minutes, providing them opportunity to coordinate their movements to optimize efficiency. After each procedure, they will receive feedback from a local airway and aerosol box expert (i.e. site investigator). Control arm teams will also have opportunity to practice intubation and/or CPR for 15 min (without aerosol box). After orientation and training, teams will participate in two sequential simulation scenarios. The order of scenario delivery will be randomized to eliminate scenario order as a potential confounder. At the end of the entire session, participants will receive an educational debriefing to discuss performance issues, infection control measures, and technical skills using a blended-method approach to debriefing. The Investigators elected not to use a cross-over study design because of insufficient washout time (between scenarios) and the potential carry-over effects of learning from the prior scenario influencing performance in the subsequent scenario.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Cardiac Arrest COVID-19 Coronavirus

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

RANDOMIZED

Intervention Model

PARALLEL

Primary Study Purpose

OTHER

Blinding Strategy

NONE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Aerosol Box

The team will complete the resuscitation scenario with an Aerosol box placed.

Group Type EXPERIMENTAL

Aerosol box

Intervention Type DEVICE

The aerosol box is a transparent, plastic cube covering the patient's head and shoulders, with circular access ports on the front of the box allowing for access to manage the airway. An additional four access holes (i.e. two on either side of the box) allow for airway assistants to access the patient airway.

No Aerosol Box

The team will complete the resuscitation scenario without an Aerosol box placed.

Group Type NO_INTERVENTION

No interventions assigned to this group

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Aerosol box

The aerosol box is a transparent, plastic cube covering the patient's head and shoulders, with circular access ports on the front of the box allowing for access to manage the airway. An additional four access holes (i.e. two on either side of the box) allow for airway assistants to access the patient airway.

Intervention Type DEVICE

Other Intervention Names

Discover alternative or legacy names that may be used to describe the listed interventions across different sources.

Splashguard

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

Airway Provider:

* Attending physician, fellow or resident in adult or pediatric emergency medicine, pediatric intensive care, general pediatrics or pediatric/adult anesthesia
* Adult or Pediatric Advanced Life Support certification.

CPR Provider:

* Attending physician, resident, fellow, nurse, respiratory therapist, physician assistant or health care aide
* Basic Life Support, Adult or Pediatric Advanced Life Support certification

Exclusion Criteria

* Decline to provide informed consent
* Unable to perform tasks required of the role due to physical limitations.
Minimum Eligible Age

18 Years

Maximum Eligible Age

60 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

Yes

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Canadian Institutes of Health Research (CIHR)

OTHER_GOV

Sponsor Role collaborator

KidSIM Simulation Program

NETWORK

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Adam Cheng

Professor, Departments of Pediatrics and Emergency Medicine

Responsibility Role PRINCIPAL_INVESTIGATOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Adam C Cheng, MD

Role: PRINCIPAL_INVESTIGATOR

University of Calgary

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Department of Emergency Medicine, Children's Hospital of Los Angeles

Los Angeles, California, United States

Site Status RECRUITING

KidSIM, Alberta Children's Hospital

Calgary, Alberta, Canada

Site Status RECRUITING

Department of Pediatrics, The Hospital for Sick Children

Toronto, Ontario, Canada

Site Status RECRUITING

Department of Pediatrics, CHU Sainte-Justine

Montreal, Quebec, Canada

Site Status COMPLETED

Countries

Review the countries where the study has at least one active or historical site.

United States Canada

Central Contacts

Reach out to these primary contacts for questions about participation or study logistics.

Adam Cheng, MD

Role: CONTACT

(403)955-2633

Facility Contacts

Find local site contact details for specific facilities participating in the trial.

Todd Chang, MD

Role: primary

Adam Cheng, MD FRCPC

Role: primary

4039552633

Jonathan Pirie, MD

Role: primary

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

REB23-0184

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

The VENTOR Clinical Study
NCT06759389 RECRUITING NA
Ventilation Monitoring in OHCA
NCT04988906 COMPLETED NA
Four Methods of Pre-oxygenation
NCT02708862 COMPLETED NA
Ventilation in Cardiac Arrest
NCT04657393 TERMINATED NA