Conditionally Increased Output (CIO) Enhanced Ultrasound System
NCT ID: NCT05792423
Last Updated: 2025-05-23
Study Results
Outcome measurements, participant flow, baseline characteristics, and adverse events have been published for this study.
View full resultsBasic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
NA
24 participants
INTERVENTIONAL
2023-06-30
2024-05-31
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Safety and Effectiveness Evaluation of the High-intensity Focused Ultrasound Device for Lifting Lax Submental and Neck Tissue
NCT07229430
A Multicenter,2-Arm,Randomized,Controlled Study Evaluate the Effectiveness of the UltraShape® Contour I VER 3.1 System for Non-Invasive Reduction in Abdominal Circumference
NCT01462201
Development Of Medical Ultrasound Systems, Accessories, And Components - GE Bangalore
NCT02946242
Fat Layer Reduction in the Lateral Thighs Using CoolSculpting
NCT02324816
UltraShape Power for Abdominal Fat and Circumference Reduction
NCT02748928
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Liver biopsy is currently accepted as the gold-standard method to detect liver fibrosis, though it is an invasive procedure with high morbidity and mortality rates. Alternatively, imaging is useful for NAFLD diagnosis, disease management, and monitoring treatment response. Several imaging methods are used for these purposes, including ultrasound, MRI, and CT based techniques. Ultrasound (US) is preferred by many physicians because it is a low-cost technique that is widely available. Shear wave elastography (SWE) is an ultrasound-based technique that is commonly used for liver fibrosis staging. When performing ultrasound imaging, it is known that several patient-related factors may influence the quality of the image.
In NAFLD patients, several factors including high skin-to-liver capsule distance (SCD) may change the attenuation and aberration of the acoustic waves, change the quality of the image, and make diagnosis harder for radiologists. SCD is the distance between skin and Glisson's capsule, when assessed with standard B-mode ultrasound imaging. In patients with high SCD, and particularly in patients with abdominal obesity, the shear wave elasticity elastogram box may not fill properly, which may cause unreliable SWE measurements. Technical failure and unreliable SWE measurements have been previously reported.
The current FDA guidelines recommend the use of a maximum derated spatial peak temporal average intensity (ISPTA) of ≤ 720 mW/cm2, and either the maximum MI should be ≤ 1.9 or the maximum derated spatial peak pulse average intensity (ISPPA) should be ≤ 190 W/cm2. In addition, clinical justification is required if the TI exceeds 6. Several diagnostic modes that are clinically used and FDA approved use acoustic output values that approach these maximum guidelines. These diagnostic modes include acoustic radiation force impulse (ARFI) based techniques, harmonic imaging techniques, and Doppler based techniques. In the past decade, the AIUM has published reports on the benefits and limitations of both the TI and MI, including recommendations that transient increases may be warranted if there were associated clinical benefit.
Using the acoustic and thermal limits in current FDA guidelines, it is not always possible to get reliable SWE measurements. Therefore, conditionally increasing the acoustic pressure of a SWE system may help clinicians to obtain reliable and accurate SWE results from patients with abdominal obesity, potentially minimizing the need for liver biopsy.
This study aims to assess possible bioeffects that may be caused by the use of SWE with conditionally increased acoustic output pressure (CIO). Bioeffects will be monitored by of a series of liver function tests (LFTs) with results graded according to the NCI scale for drug hepatoxicity. LFTs will be collected prior to SWE imaging using CIO, as well up to 7 days post-imaging. Secondarily, this study aims to understand the degree to which SWE imaging results have improved with the use of COI.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NA
SINGLE_GROUP
OTHER
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
24 healthy adult volunteers
GE ultrasound system with increased acoustic output settings
We will perform liver stiffness measurements with standard settings and an increased acoustic output enhanced ultrasound system. Pre and post ultrasound LFTs will be collected to monitor unexpected liver tissue damage.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
GE ultrasound system with increased acoustic output settings
We will perform liver stiffness measurements with standard settings and an increased acoustic output enhanced ultrasound system. Pre and post ultrasound LFTs will be collected to monitor unexpected liver tissue damage.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* BMI 18.5-39.9
* Able to undergo abdominal ultrasound
* Able to undergo repeated blood sampling
* Stable medication and supplement list and dosing for 30 days preceding enrollment
* Willing to participate
Exclusion Criteria
* Current diagnosis of drug induced liver injury
* Prior liver transplantation recipient
* Receiving drug/placebo in treatment trial now or within 30 days
* Received systemic chemotherapy within past 30 days.
* Confirmed or suspected pregnancy
* Pacemaker, nerve stimulator, or other implanted electronic device
* Plans to alter medication or supplement list or dosage during the study period
* Active or recent (within 30 days) acute illness
* Recent ultrasound contrast administration
* Recent alanine transaminase (ALT), aspartate transaminase (AST), or alkaline phosphatase (ALP) greater than the laboratory upper limit of normal.
* Other factors that the PI considers likely to compromise study endpoints or subject safety
18 Years
65 Years
ALL
Yes
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
GE Healthcare
INDUSTRY
Massachusetts General Hospital
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Anthony Samir
Service Chief, Ultrasound, Department of Radiology
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Massachusetts General Hospital
Boston, Massachusetts, United States
Countries
Review the countries where the study has at least one active or historical site.
Provided Documents
Download supplemental materials such as informed consent forms, study protocols, or participant manuals.
Document Type: Study Protocol and Statistical Analysis Plan
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
2022P003180
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.