Feasibility and Utility of Artificial Intelligence (AI) / Machine Learning (ML) - Driven Advanced Intraoperative Visualization and Identification of Critical Anatomic Structures and Procedural Phases in Laparoscopic Cholecystectomy
NCT ID: NCT05775133
Last Updated: 2024-02-21
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
RECRUITING
NA
120 participants
INTERVENTIONAL
2023-08-01
2025-12-31
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
The AI will not alter the surgeon's view or be visible to the surgeon, and the surgeon will perform the procedure in the exact same fashion as they typically do.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
AI and Safety in Laparoscopic Cholecystectomy: A Randomized Controlled Trial
NCT07186803
Using AI and Fluorescence Guidance to Enhance Extrahepatic Bile Duct Identification Among Junior Surgeons During Laparoscopic Cholecystectomy
NCT07188181
Research on Identifying Critical Surgical Anatomy in Cholecystectomy Videos Based on Deep Learning
NCT07158372
Feasibility of the Ultravision™ System in Low Pressure Laparoscopic Cholecystectomy Compared to Airseal® IFS
NCT04162106
LC-Smart: A Deep Learning-Based Quality Control Model for Laparoscopic Cholecystectomy
NCT06732271
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Most major biliary injuries result from unrecognized or unintended perception, either misidentification or misinterpretation of the common bile or hepatic duct as the cystic duct or misidentification of an aberrant bile duct. It is increasingly clear that the routine use of intraoperative cholangiography (IOC) has a significant association with decreased and earlier intraoperative detection of BDI. The recent 'state of the art consensus conference on prevention of bile duct injury during cholecystectomy' in 2018 strongly recommended that documenting the critical view of safety (CVoS) and a liberal use of IOC in anticipated difficult cholecystectomy are highly recommended steps that can potentially mitigate the risk of BDI during laparoscopic cholecystectomy (LC) in patients especially with uncertain anatomy or difficult dissection.
Performing traditional IOC laparoscopically under fluoroscopic guidance however can challenge surgeons' skills, is time-consuming, and requires a learning curve to interpret images. Despite well-known and accepted risk factors for difficult cholecystectomies and potential for BDI, the use of advanced imaging for IOC however remains variable and highly user dependent. The rationale for selective use of IOC is attributable to the fact that the prevalence and incidence of BDI are low that an individual practitioner would infrequently encounter such complication in their daily practice or lifetime of a surgeon to justify a routine use. This is further compounded by the fact that radiation-based fluoroscopic IOC are cumbersome to efficient workflow, utility and cost (need for contrast reagent preparation and injection, potential adverse allergic reactions, risk of radiation exposure, training requirement, need for large capital equipment, space and cost), and variability in proficient analysis.
Recent randomized controlled trials using near-infrared fluorescent cholangiography (NIFC) using indocyanine green (ICG) demonstrated significantly superior visualization of extrahepatic biliary structures during laparoscopic cholecystectomy to white light (WLI) alone. Pre-dissection surgeon detection rates on naked eye were significantly higher (\> 1.8 - 3.1 folds) with NIFC use for all 7 biliary structures than traditional WLI alone. However, although similar intergroup differences were observed for all structures, addition of NIFC did not improve additional detection of cystic duct and cystic duct/gallbladder junction after dissection has been done. In addition, increased body mass index was associated with reduced detection of most structures in both groups, especially before dissection. Interestingly, only 2 patients, both in the WLI group, sustained a biliary duct injury.
ActivSightTM is an FDA-cleared device that combines ICG fluorescence for extrahepatic biliary visualization and laser speckle contrast imaging (LSCI) for perfusion detection in a laparoscopic form factor. ActivSightTM allows augmented visualization to any current WLI laparoscopic visualization system displaying both extrahepatic biliary ICG and microperfusion over cystic duct and artery. As a non-significant risk device, ActivSightTM has been used in well over 150 patients for laparoscopic cholecystectomies and bariatric, esophageal, and colorectal procedures, with proven safety and utility. Moreover, ActivSightTM allows raw infrared visualization data for advanced analysis and AI/ML model development.
Surgeons/scientists now have segmented and analyzed different procedural phases of LC, and developed inferencing models and algorithms using artificial intelligence (AI)/machine learning (ML) based on standard WLI procedural videos. Although AI/ML models recognizing different phases of LC procedures can be as accurate as 80-95% on limited trained dataset once structures have been clearly dissected, more relevant and key value would be in identifying critical structures such as bile ducts and arteries before and during, not after surgical dissection has been performed. Early detection and identification of these critical structures before and during dissection of the triangle based on AI/ML trained on computer vision may aid surgeons in performing more effective and safer LC.
ActivSightTM is an FDA 510(k)-cleared optical imaging system based on monochromatic coherent light known as Laser-speckle-contrast imaging (LSCI) and represents a label-free imaging method using coherent monochromatic light where blood flow and tissue perfusion can be detected. A small imaging module that fits between any existing laparoscope and camera systems and a separate light source placed along any current commercial system will deliver objective real-time tissue perfusion and blood flow information intraoperatively. In addition, ActivSightTM can also effectively display with push of button an ICG-based visualization of the biliary tree in real time at equivalent or superior to current commercial products. The innovative form factor of ActivSight enables any laparoscopic system for ICG-based visualization at a fraction of the cost of current competitor with minimal disruption to workflow.
ActivInsightTM is a prototype software feature in ActivSightTM that recognizes procedural phases and critical anatomic structures, namely gallbladder, cystic duct, and cystic artery during LC using AI/ML-based algorithms. The key difference of ActivInsightTM to other models reported in the literature is that ActivInsightTM is trained on dataset annotated using ICG and LSCI in addition to WLI.
In this trial, the investigators propose to first validate and then test the precision and accuracy of ActivInsightTM in detecting critical phases and structures and compare the performance of the algorithms to those based on models developed using WLI only and traditional surgeon's naked eye detection during LC in pre-and mid-dissection phases. To eliminate any bias, the investigators will connect a secondary screen blinded to the main operating surgeon screens so that real-time function of the AI/ML is not visible to operating surgeons, to perform real-time analysis and comparison of routine use of advanced augmented visualization versus current WLI visualization alone with or without computer vision-based AI/ML.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
RANDOMIZED
PARALLEL
DIAGNOSTIC
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Indocyanine green (ICG)
Patients in this arm will receive an intravenous injection of indocyanine green (ICG) 45 minutes prior to the start of surgery. This will be used to visualize the biliary anatomy using ActivSight, a device that is FDA 510(k)-cleared for this indication.
The surgeon will perform the procedure in their standard fashion using ActivSight.
ActivInsight artificial intelligence will be used to analyze the surgical video in real time to identify anatomic structures and phases of surgery.
ICG
Patient will receive a standard dose of indocyanine green (ICG) 45 minutes prior to surgery. ActivSight will be used during laparoscopic cholecystectomy - the surgeon will perform the procedure in their standard fashion.
Video data will be analyzed in real-time by Activ Surgical's ActivInsight surgical artificial intelligence platform to identify anatomic structures and surgical phase. The surgeon will be blinded to this information, and will see the standard screens and information they do when performing the procedure in a non-study setting.
Non-Indocyanine Green (Non-ICG)
The surgeon will perform the procedure in their standard fashion without the use of ICG.
ActivInsight artificial intelligence will be used to analyze the surgical video in real time to identify anatomic structures and phases of surgery.
No interventions assigned to this group
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
ICG
Patient will receive a standard dose of indocyanine green (ICG) 45 minutes prior to surgery. ActivSight will be used during laparoscopic cholecystectomy - the surgeon will perform the procedure in their standard fashion.
Video data will be analyzed in real-time by Activ Surgical's ActivInsight surgical artificial intelligence platform to identify anatomic structures and surgical phase. The surgeon will be blinded to this information, and will see the standard screens and information they do when performing the procedure in a non-study setting.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Eligible patients will be screened and assigned as per risk calculator for difficulty of LC
* Diagnosis:
* All patients with clinical suspicion and diagnosis of symptomatic cholelithiasis or cholecystitis planned for cholecystectomy.
* Typical imaging as per standard workup findings including US, CT and/or MRI. Plain radiographs and contrast imaging may be obtained by referring physicians and are helpful for confirming the clinical diagnosis.
* Prior therapy:
o Patients with prior surgery are eligible for enrollment.
* Laboratory:
* Hemoglobin \> 9 g/dL
* Platelet count ≥75,000/µL (may receive transfusions)
* Normal prothrombin time (PT), partial thromboplastin time (PTT) and international normalized ratio (INR) \< 1.5 x upper limit of normal (including patients on prophylactic anticoagulation)
* Liver Function Test
* Renal function: Age-adjusted normal serum creatinine
* Adequate pulmonary function: Defined as no dyspnea at rest, and a pulse oximetry \>94% on room air if there is any clinical indication for determination.
Exclusion Criteria
* Patients assigned to FDA cleared ICG-based visualization are contraindicated for any chronic renal dysfunction, potential drug interaction, history of allergy to ICG or anaphylaxis, and pregnancy.
* Patients currently in any investigational agents.
* Adults unable to consent
* Individuals under 18 years of age
* Pregnant women
* Prisoners
* Vulnerable populations
18 Years
ALL
Yes
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Activ Surgical
INDUSTRY
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Peter Kim, MD, PhD
Role: PRINCIPAL_INVESTIGATOR
Activ Surgical
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Memorial Hermann Texas Medical Center
Houston, Texas, United States
Countries
Review the countries where the study has at least one active or historical site.
Central Contacts
Reach out to these primary contacts for questions about participation or study logistics.
Facility Contacts
Find local site contact details for specific facilities participating in the trial.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
20220620
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.