Accuracy of Real Time Characterization in Artificial Intelligence-assisted Colonoscopy

NCT ID: NCT05754229

Last Updated: 2024-02-13

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

ACTIVE_NOT_RECRUITING

Clinical Phase

NA

Total Enrollment

395 participants

Study Classification

INTERVENTIONAL

Study Start Date

2022-10-01

Study Completion Date

2025-09-30

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

The goal of this substudy is to investigate the accuracy of a computer-aided polyp characterization (CADx) system. The main question\[s\] it aims to answer are:

• How high is the specificity of the AI system when characterizing colorectal polyps

Participants will receive a standard colonoscopy, assisted by the artificial intelligence (AI) assisted system GI Genius.

Researchers will compare the AI system´s characterization with the histopathology to see how accurate the system is.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Colorectal cancer (CRC) is the third most common cancer, and the second most common cause of cancer-related death worldwide. CRC screening is used for detection and removal of precancerous lesions before they develop into cancer. Colonoscopy is regarded being superior to other screening tests, and is therefore used as the golden standard.

Screening colonoscopy is associated with a reduced risk of CRC-related death. Since it is not possible for an endoscopist to determine the histopathology of the polyp with certainty during a colonoscopy, detected pre-malignant lesions should be removed and sent for histological examination. Multiple studies have shown that there is a strong association between findings at the baseline screening colonoscopy and rate of serious lesions at the follow up colonoscopy. Risk factors for adenoma, advanced adenoma and cancer at follow-up colonoscopy are multiplicity, size, villousness, and high degree dysplasia of the adenomas at the baseline screening colonoscopy.

Within the last few years there have been published several randomized controlled trials (RCT) investigating the efficacy of real time computer-aided detection. Studies have shown that AI contributes to a significantly higher adenoma detection rate (ADR), compared colonoscopies without assistance of an AI system.There have been concerns about prolonged colonoscopy time, and increased workload if implementing the AI-system, since the increased detection of small polyps may lead to unnecessary polypectomy.

With the development of computer-aided polyp characterization (CADx) systems, it is possible to use AI for decision support and not only for detection. There is no evidence yet that the CADx system increases the sensitivity for small neoplastic polyps when used by non-expert endoscopists (accredited for standard colonoscopy), but it may improve the clinicians confidence, and increase the specificity for optical diagnosis (Barua et al).

Diminutive polyps (1-5 mm) in the rectosigmoid colon can be left in situ when diagnosed with high confidence with a sensitivity of at least 90% and a specificity of at least 80%. To implement the resect-and-discard strategy, a sensitivity of at least 80% is acceptable. This is recommended by the European Society of Gastrointestinal Endoscopy (ESGE) as a strategy to decrease the unnecessary removal of small polyps with a negligible risk of harbouring cancer. Although the resect-and-discard strategy is assessed to be a safe and cost-effective method, it is important to be cautious with lesions in the right colon due to their malignant potential.

Reliable CADx systems could enable a more targeted removal of neoplastic polyps, while diminutive non-neoplastic polyps could be left behind. The potential excessive workload due to the CADe system could therefore theoretically be avoided by adding the CADx system.

The results so far are promising, suggesting that AI-assisted colonoscopy is superior to conventional colonoscopy when it comes to polyp and adenoma detection. Continued improvement of CADx systems in differentiating the pathology of colorectal lesions is needed, as well as additional clinical studies to assess the potential value of the CADx system.

The overall aim of this research is to investigate the quality, and the possible benefits of AI-assistance in colonoscopy. Hopefully this can contribute to a more accurate, safe, and targeted diagnosis and treatment of patients in the future.

The investigators have designed a quality assurance study to investigate the effect of real time AI-assisted colonoscopy with the CADx system (GI Genius, Medtronic). This study "REG-093-2022" is a substudy to the RCT "REG-092-2022". The investigators wish to evaluate the diagnostic accuracy of the CADx system.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Colorectal Cancer Colorectal Adenoma Colorectal Neoplasms

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

NA

Intervention Model

SINGLE_GROUP

Primary Study Purpose

DIAGNOSTIC

Blinding Strategy

NONE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

AI-assisted colonoscopy

The patients in the intervention group will receive an AI-assisted colonoscopy (AIC) using the computer-aided polyp detection and characterization (CADe and CADx) GI Genius (Medtronic).

Group Type OTHER

AI-assisted colonoscopy

Intervention Type DEVICE

The patients will receive an AI-assisted colonoscopy (AIC) using the computer-aided polyp detection and characterization (CADe and CADx) GI Genius (Medtronic).

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

AI-assisted colonoscopy

The patients will receive an AI-assisted colonoscopy (AIC) using the computer-aided polyp detection and characterization (CADe and CADx) GI Genius (Medtronic).

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Referred for screening colonoscopy due to a positive faecal immunochemical test (FIT) or for
* Diagnostic colonoscopy due to symptoms/signs or
* Post-polypectomy surveillance colonoscopy (only patients who had all detected polyps removed in the previous colonoscopy)

Exclusion Criteria

* Referral for removal of previous detected polyps
* Emergency colonoscopy
* Control colonoscopy due to inflammatory bowel disease (IBD)
Minimum Eligible Age

18 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

Yes

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Nykøbing Falster County Hospital

OTHER

Sponsor Role collaborator

Naestved Hospital

OTHER

Sponsor Role collaborator

Holbaek Sygehus

OTHER

Sponsor Role collaborator

Slagelse Hospital

OTHER

Sponsor Role collaborator

Ismail Gögenur

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Ismail Gögenur

Professor, DMSc

Responsibility Role SPONSOR_INVESTIGATOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Ronja Lagström, MD

Role: PRINCIPAL_INVESTIGATOR

Zealand University Hospital, Køge

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Holbæk Hospital

Holbæk, , Denmark

Site Status

Zealand University Hospital

Køge, , Denmark

Site Status

Nykøbing Falster County Hospital

Nykøbing Falster, , Denmark

Site Status

Næstved Hospital

Næstved, , Denmark

Site Status

Countries

Review the countries where the study has at least one active or historical site.

Denmark

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

REG-093-2022

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.