Accuracy of Real Time Characterization in Artificial Intelligence-assisted Colonoscopy
NCT ID: NCT05754229
Last Updated: 2024-02-13
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
ACTIVE_NOT_RECRUITING
NA
395 participants
INTERVENTIONAL
2022-10-01
2025-09-30
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
• How high is the specificity of the AI system when characterizing colorectal polyps
Participants will receive a standard colonoscopy, assisted by the artificial intelligence (AI) assisted system GI Genius.
Researchers will compare the AI system´s characterization with the histopathology to see how accurate the system is.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Adenoma Detection Rate in Artificial Intelligence-assisted Colonoscopy
NCT05740137
Artificial Intelligence (AI) Assisted Real-time Adenoma Detection and Classification During Colonoscopies
NCT05244278
A Prospective Randomized Study Comparing the Adenoma Detection Yield of SC, AI and Combined AI and G-EYE®
NCT05317351
Efficacy of Artificial Intelligence-assisted Colonic Polyp Detection System
NCT05941689
Nationwide Study of Artificial Intelligence in Adenoma Detection for Colonoscopy
NCT05870332
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Screening colonoscopy is associated with a reduced risk of CRC-related death. Since it is not possible for an endoscopist to determine the histopathology of the polyp with certainty during a colonoscopy, detected pre-malignant lesions should be removed and sent for histological examination. Multiple studies have shown that there is a strong association between findings at the baseline screening colonoscopy and rate of serious lesions at the follow up colonoscopy. Risk factors for adenoma, advanced adenoma and cancer at follow-up colonoscopy are multiplicity, size, villousness, and high degree dysplasia of the adenomas at the baseline screening colonoscopy.
Within the last few years there have been published several randomized controlled trials (RCT) investigating the efficacy of real time computer-aided detection. Studies have shown that AI contributes to a significantly higher adenoma detection rate (ADR), compared colonoscopies without assistance of an AI system.There have been concerns about prolonged colonoscopy time, and increased workload if implementing the AI-system, since the increased detection of small polyps may lead to unnecessary polypectomy.
With the development of computer-aided polyp characterization (CADx) systems, it is possible to use AI for decision support and not only for detection. There is no evidence yet that the CADx system increases the sensitivity for small neoplastic polyps when used by non-expert endoscopists (accredited for standard colonoscopy), but it may improve the clinicians confidence, and increase the specificity for optical diagnosis (Barua et al).
Diminutive polyps (1-5 mm) in the rectosigmoid colon can be left in situ when diagnosed with high confidence with a sensitivity of at least 90% and a specificity of at least 80%. To implement the resect-and-discard strategy, a sensitivity of at least 80% is acceptable. This is recommended by the European Society of Gastrointestinal Endoscopy (ESGE) as a strategy to decrease the unnecessary removal of small polyps with a negligible risk of harbouring cancer. Although the resect-and-discard strategy is assessed to be a safe and cost-effective method, it is important to be cautious with lesions in the right colon due to their malignant potential.
Reliable CADx systems could enable a more targeted removal of neoplastic polyps, while diminutive non-neoplastic polyps could be left behind. The potential excessive workload due to the CADe system could therefore theoretically be avoided by adding the CADx system.
The results so far are promising, suggesting that AI-assisted colonoscopy is superior to conventional colonoscopy when it comes to polyp and adenoma detection. Continued improvement of CADx systems in differentiating the pathology of colorectal lesions is needed, as well as additional clinical studies to assess the potential value of the CADx system.
The overall aim of this research is to investigate the quality, and the possible benefits of AI-assistance in colonoscopy. Hopefully this can contribute to a more accurate, safe, and targeted diagnosis and treatment of patients in the future.
The investigators have designed a quality assurance study to investigate the effect of real time AI-assisted colonoscopy with the CADx system (GI Genius, Medtronic). This study "REG-093-2022" is a substudy to the RCT "REG-092-2022". The investigators wish to evaluate the diagnostic accuracy of the CADx system.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NA
SINGLE_GROUP
DIAGNOSTIC
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
AI-assisted colonoscopy
The patients in the intervention group will receive an AI-assisted colonoscopy (AIC) using the computer-aided polyp detection and characterization (CADe and CADx) GI Genius (Medtronic).
AI-assisted colonoscopy
The patients will receive an AI-assisted colonoscopy (AIC) using the computer-aided polyp detection and characterization (CADe and CADx) GI Genius (Medtronic).
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
AI-assisted colonoscopy
The patients will receive an AI-assisted colonoscopy (AIC) using the computer-aided polyp detection and characterization (CADe and CADx) GI Genius (Medtronic).
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Diagnostic colonoscopy due to symptoms/signs or
* Post-polypectomy surveillance colonoscopy (only patients who had all detected polyps removed in the previous colonoscopy)
Exclusion Criteria
* Emergency colonoscopy
* Control colonoscopy due to inflammatory bowel disease (IBD)
18 Years
ALL
Yes
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Nykøbing Falster County Hospital
OTHER
Naestved Hospital
OTHER
Holbaek Sygehus
OTHER
Slagelse Hospital
OTHER
Ismail Gögenur
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Ismail Gögenur
Professor, DMSc
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Ronja Lagström, MD
Role: PRINCIPAL_INVESTIGATOR
Zealand University Hospital, Køge
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Holbæk Hospital
Holbæk, , Denmark
Zealand University Hospital
Køge, , Denmark
Nykøbing Falster County Hospital
Nykøbing Falster, , Denmark
Næstved Hospital
Næstved, , Denmark
Countries
Review the countries where the study has at least one active or historical site.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
REG-093-2022
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.