A ProspeCtive mUlticenteR Investigation on RENzar Stent Safety and Efficacy in the Treatment of Patients With Femoro-popliteal Disease in Tuscany (CURRENT Registry)
NCT ID: NCT05701293
Last Updated: 2023-07-20
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
RECRUITING
100 participants
OBSERVATIONAL
2022-12-01
2026-12-01
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Study of Drug Eluting Peripheral Vascular Stent System in Superficial Femoral Artery Stenosis and /or Occlusion
NCT03121430
Analysis of the Different Strategies for Revascularization of the Lower Limbs by Peripheral Angioplasty
NCT05155462
Endovascular Treatment of Primary Common FEmoral Artery atheroSclerotic Disease wiTh IntraVAscular Litothripsy
NCT05821829
Fatigue Behavior of Peripheral STENt of the Superficial Femoral Artery
NCT06198920
Evaluate the Efficacy and Safety of the Cilostazol-coated BioMimics 3D Stent System in Patients with Peripheral Arterial Occlusive Disease
NCT05759819
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Still, a lot of rumours have been generated on the potential local and systemic toxicity of paclitaxel.
As a consequence, in complex lesion rather than Drug Coated Balloon and Drug Eluting Stent it seems that there is need of a modern generation of nitinol stents with high Radial Resistive Force, low chronic outward forces and high fracture resistance.
The device under investigation is the Renzan™ Peripheral Stent System from Terumo MicroVention Inc. (35 Enterprise, Aliso Viejo, California 92656, USA) .
The System consists of a self-expanding nitinol stent pre-mounted on the distal portion of a rapid exchange (RX) delivery catheter. The stent is made of a nickel-titanium alloy with radiopaque markers on each end of the stent. The nitinol stent is constructed from 2 layers of tubular braided nitinol wire mesh. The outer layer consists of nitinol wire braided into a closed cell structure with flared ends. The inner layer consists of nitinol wire braided into a closed cell structure with micro sized pores. The delivery catheter has a rapid exchange port designed to allow coaxial passage of a 0.46mm (0.018") or smaller guide wire in diameter. The stent is capable of being recaptured when a minimum of 20mm of stent length remains inside the catheter.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
COHORT
PROSPECTIVE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
LEAD patients undergoing endovascular treatment with implantation of Renzan stent
Endovascular implantation of Renzan Stent
Endovascular treatment of LEAD patients with Renzan Stent
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Endovascular implantation of Renzan Stent
Endovascular treatment of LEAD patients with Renzan Stent
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
2. Subject must provide written informed consent prior to the treatment of the target lesion.
3. Subject must be willing to comply with the specified follow-up evaluation schedule.
4. Subject with Rutherford-Becker clinical classification category 2 to 5, with a resting ankle-brachial index (ABI) ≤ 0.9.
5. Common femoral, superficial femoral and/or popliteal artery lesion with \> 50% stenosis or total occlusion.
6. Stenotic or occluded lesion(s) within the same vessel with no length limits.
7. De novo or restenotic/occluded lesion(s) including in-stent restenosis, with reference vessel diameter (RVD) ≥ 4.0 mm and ≤ 8.0 mm by visual assessment and no length limits.
8. Multiple RENZAN stents could be deployed with a mandatory overlap of 0.5-1 cm.
9. A patent inflow artery free from the significant lesion (≥50% stenosis) as confirmed by angiography (treatment of target lesion acceptable after successful treatment of ipsilateral iliac lesions); Successful ipsilateral iliac artery treatment is defined as the attainment of residual diameter stenosis ≤30%, either with PTA or stenting.
10. The target lesion(s) can be successfully crossed with a guide wire and dilated up to 1:1 to the proposed stent to be implanted (as per the operator's assessment).
11. At least one patent native outflow artery (anterior or posterior tibial or peroneal), free from significant (≥50%) stenosis (as confirmed by angiography), that has not previously been revascularized. The remaining outflow arteries requiring treatment during the same procedure may be treated
Exclusion Criteria
2. Treatment of lesions requiring the use of adjunctive debulking devices.
3. Use of drug-eluting balloon or stent
4. Inadequate vessel preparation not achieving a diameter of 1:1 to the stent to be implanted (with ≤20% residual stenosis, as per operator's assessment).
5. Concomitant use of different stent platforms
6. Any significant vessel tortuosity or other parameters prohibiting access to the lesion and/or preventing the stent delivery.
7. Subject with coronary intervention performed less than 90 days prior to or planned within 30 days after the treatment of the target lesion.
8. Known allergies or intolerance to nitinol (nickel titanium).
9. Any contraindication or known unresponsiveness to dual antiplatelet therapy (DAPT) or anticoagulation therapy.
10. Presence of acute thrombus prior to crossing the lesion.
11. Thrombolysis of the target vessel within 72 hours prior to the index procedure
12. Thrombophlebitis or deep venous thrombus, within the previous 30 days.
13. Subject receiving dialysis within the previous 30 days.
14. Stroke within the previous 90 days.
15. Subject is pregnant or of childbearing potential
16. Subject has a life expectancy of less than 1 year.
17. Subject is participating in an investigational study that has not reached the primary endpoint at the time of study screening.
18. Only one patent outflow artery, with significant stenosis (≥50%) (as confirmed by angiography)
18 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
University of Florence
OTHER
Azienda Ospedaliera Universitaria Senese
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Gianmarco de Donato
Professor
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
University of Siena
Siena, , Italy
Countries
Review the countries where the study has at least one active or historical site.
Central Contacts
Reach out to these primary contacts for questions about participation or study logistics.
Facility Contacts
Find local site contact details for specific facilities participating in the trial.
Edoardo Pasqui, MD
Role: primary
References
Explore related publications, articles, or registry entries linked to this study.
Conte MS, Bradbury AW, Kolh P, White JV, Dick F, Fitridge R, Mills JL, Ricco JB, Suresh KR, Murad MH; GVG Writing Group. Global vascular guidelines on the management of chronic limb-threatening ischemia. J Vasc Surg. 2019 Jun;69(6S):3S-125S.e40. doi: 10.1016/j.jvs.2019.02.016. Epub 2019 May 28.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
Current01
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.