Impact of Dynamic CoROnary RoADmap System for Guidance of Instantaneous Wave-Free Ratio or Fractional Flow Reserve

NCT ID: NCT05682118

Last Updated: 2026-02-11

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

RECRUITING

Clinical Phase

NA

Total Enrollment

226 participants

Study Classification

INTERVENTIONAL

Study Start Date

2023-07-31

Study Completion Date

2026-11-27

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

In patients with 50-90% stenosis of the coronary artery, the coronary roadmap (dynamic roadmap) is performed when the conventional fractional flow reserve (FFR) and instantaneous wave-free ratio (iFR) are performed. coronary roadmap system) to confirm the effectiveness of the function.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

In coronary angiography, 50% or more stenosis of the causative vessel is observed in a patient with stable angina pectoris (SAP) or 50% or more stenosis of a non-causative vessel is observed in acute coronary syndrome (ACS) Based on 0.90, if it is less than 0.89, PCI is performed, and if it is 0.90 or more, drug treatment is performed. When the pressure wire tests are performed, the pressure wire is inserted from the origin of the blood vessel through the lesion to the distal portion, and the pressure wire is placed at the distal end of the blood vessel for measurement. In this process, there are many cases where the pressure wire escapes the branch blood vessel or does not pass through well. It takes a long time to stand up and evaluate stenosis, and in many cases, an additional contrast medium is used to additionally check blood vessel travel and to check the position and condition of the pressure wire. To overcome this, the software roadmap installed in the cardiac fluoroscopy device of the cardiac catheterization room can be helpful. However, there are currently no studies related to roadmaps in coronary artery examination. Therefore, in this study, we want to evaluate the effectiveness of the roadmap when examining FFR and iFR.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Ischemic Heart Disease

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

RANDOMIZED

Intervention Model

PARALLEL

The sample size was calculated using effect size (Cohen's d) for the effectiveness of the dynamic coronary roadmap system for the guidance of the iFR and FFR. The effect size was assumed to be 0.4, which is a small to medium effect size. The sample size of 113 participants for each group was estimated to provide 90% power with a 2-sided type I error of 0.05.

This is a single-center randomized study and will be conducted in 226 patients with 50-90% coronary artery stenosis on angiography. Afterward, randomly assigned, 113 patients will be tested using the roadmap system, and 113 patients will be tested without using the roadmap system. Methods for measuring FFR and iFR and all PCI will use standardized testing and procedure methods.
Primary Study Purpose

TREATMENT

Blinding Strategy

NONE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

tested using the roadmap system

tested using the roadmap system

Group Type EXPERIMENTAL

roadmap

Intervention Type PROCEDURE

FFR and iFR tests using the roadmap system, or FFR and iFR tests without using the roadmap system.

Pressure wire into guiding catheter The equalization of the pressure wire with the aortic pressure(after placing the pressure wire on the tip of the guiding catheter and removal of contrast media by saline flushing) and the placement of the pressure wire on the distal of the blood vessel to measure iFR. After iFR measurement, the pressure wire was pulled back into the tip of the guiding catheter to check the presence of pressure drift. A final Pd/Pa between 0.97 and 1.03 is considered acceptable. Following confirming no pressure drift, a mode change will be done from iFR to FFR, and then a re-check of the time between the equalization of the pressure wire with the aortic pressure will be planned. In all lesions, FFR value were measured with hyperemia, achieved by intracoronary (IC) bolus injection of nicorandil (Sigmart®; Chugai Pharmaceutical Co., Ltd., Tokyo, Japan) 2 mg.

iFR/FFR

Intervention Type PROCEDURE

Patients undergoing pressure wire test with moderate stenosis. Pressure wire into guiding catheter The equalization of the pressure wire with the aortic pressure(after placing the pressure wire on the tip of the guiding catheter and removal of contrast media by saline flushing) and the placement of the pressure wire on the distal of the blood vessel to measure iFR. After iFR measurement, the pressure wire was pulled back into the tip of the guiding catheter to check the presence of pressure drift. A final Pd/Pa between 0.97 and 1.03 is considered acceptable. Following confirming no pressure drift, a mode change will be done from iFR to FFR, and then a re-check of the time between the equalization of the pressure wire with the aortic pressure will be planned. In all lesions, FFR value were measured with hyperemia, achieved by intracoronary (IC) bolus injection of nicorandil (Sigmart®; Chugai Pharmaceutical Co., Ltd., Tokyo, Japan) 2 mg.

tested without using the roadmap system

tested without using the roadmap system.

Group Type ACTIVE_COMPARATOR

iFR/FFR

Intervention Type PROCEDURE

Patients undergoing pressure wire test with moderate stenosis. Pressure wire into guiding catheter The equalization of the pressure wire with the aortic pressure(after placing the pressure wire on the tip of the guiding catheter and removal of contrast media by saline flushing) and the placement of the pressure wire on the distal of the blood vessel to measure iFR. After iFR measurement, the pressure wire was pulled back into the tip of the guiding catheter to check the presence of pressure drift. A final Pd/Pa between 0.97 and 1.03 is considered acceptable. Following confirming no pressure drift, a mode change will be done from iFR to FFR, and then a re-check of the time between the equalization of the pressure wire with the aortic pressure will be planned. In all lesions, FFR value were measured with hyperemia, achieved by intracoronary (IC) bolus injection of nicorandil (Sigmart®; Chugai Pharmaceutical Co., Ltd., Tokyo, Japan) 2 mg.

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

roadmap

FFR and iFR tests using the roadmap system, or FFR and iFR tests without using the roadmap system.

Pressure wire into guiding catheter The equalization of the pressure wire with the aortic pressure(after placing the pressure wire on the tip of the guiding catheter and removal of contrast media by saline flushing) and the placement of the pressure wire on the distal of the blood vessel to measure iFR. After iFR measurement, the pressure wire was pulled back into the tip of the guiding catheter to check the presence of pressure drift. A final Pd/Pa between 0.97 and 1.03 is considered acceptable. Following confirming no pressure drift, a mode change will be done from iFR to FFR, and then a re-check of the time between the equalization of the pressure wire with the aortic pressure will be planned. In all lesions, FFR value were measured with hyperemia, achieved by intracoronary (IC) bolus injection of nicorandil (Sigmart®; Chugai Pharmaceutical Co., Ltd., Tokyo, Japan) 2 mg.

Intervention Type PROCEDURE

iFR/FFR

Patients undergoing pressure wire test with moderate stenosis. Pressure wire into guiding catheter The equalization of the pressure wire with the aortic pressure(after placing the pressure wire on the tip of the guiding catheter and removal of contrast media by saline flushing) and the placement of the pressure wire on the distal of the blood vessel to measure iFR. After iFR measurement, the pressure wire was pulled back into the tip of the guiding catheter to check the presence of pressure drift. A final Pd/Pa between 0.97 and 1.03 is considered acceptable. Following confirming no pressure drift, a mode change will be done from iFR to FFR, and then a re-check of the time between the equalization of the pressure wire with the aortic pressure will be planned. In all lesions, FFR value were measured with hyperemia, achieved by intracoronary (IC) bolus injection of nicorandil (Sigmart®; Chugai Pharmaceutical Co., Ltd., Tokyo, Japan) 2 mg.

Intervention Type PROCEDURE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

1. Patients aged 19 years or older
2. Patients with stable angina, including asymptomatic ischemic heart disease, who have 50-90% stenosis of the causative vessel by coronary angiography
3. Acute coronary syndrome patients with multivessel disease and 50-90% stenosis of non-caused vessels that did not cause acute coronary syndrome
4. Patients who voluntarily decided to participate in this study and gave written consent to the subject consent form

Exclusion Criteria

1. Patients with acute coronary syndrome and single vessel disease
2. Patients who have undergone previous coronary artery bypass grafting
3. Poor coronary blood flow (TIMI grade ≤ 2)
4. If life expectancy is less than one year
5. Women who are pregnant or wish to become pregnant
Minimum Eligible Age

19 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Philips Healthcare

INDUSTRY

Sponsor Role collaborator

Yonsei University

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Yongcheol Kim

Clinical Associate Professor

Responsibility Role PRINCIPAL_INVESTIGATOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Yongcheol Kim, MD, PhD

Role: PRINCIPAL_INVESTIGATOR

Severance Hospital

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Yongcheol Kim

Yongin, Gyeonggi-do, South Korea

Site Status RECRUITING

Countries

Review the countries where the study has at least one active or historical site.

South Korea

Central Contacts

Reach out to these primary contacts for questions about participation or study logistics.

Yongcheol Kim, MD, PhD

Role: CONTACT

+823151898967

Ji Woong Roh, MD, PhD

Role: CONTACT

+823151898792

Facility Contacts

Find local site contact details for specific facilities participating in the trial.

Yongcheol Kim, MD

Role: primary

+823151898967

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

9-2022-0134

Identifier Type: -

Identifier Source: org_study_id