Safety and Efficacy of the GeminiOne Transcatheter Valve Edge-to-Edge Repair System in Patients With Moderate-severe or Severe Degenerative Mitral Regurgitation
NCT ID: NCT05655897
Last Updated: 2024-06-05
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
RECRUITING
NA
120 participants
INTERVENTIONAL
2022-11-24
2029-11-24
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Valveclip® Transcatheter Mitral Valve Repair Study
NCT05021614
Transcatheter Versus Standard Surgical Mitral Valve Operation for Secondary Mitral Regurgitation
NCT05090540
DragonFly M2 Pivotal Study
NCT07243197
J-Valve Transfemoral Pivotal Study
NCT06455787
MitralStitch Mitral Valve Repair System for Mitral Regurgitation
NCT04061837
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NA
SINGLE_GROUP
TREATMENT
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
A single set of test
The GeminiOne Transcatheter Valve Edge-to-Edge Repair System consists of a transcatheter valve clamping system and an adjustable curved introducer catheter.
GeminiOne Transcatheter Valve Edge-to-Edge Repair System
The transcatheter valve clamp system consists of a valve clamp, an adjustable bend mid-tube, and a manipulated inner tube. The adjustable bend introducer catheter consists of an adjustable bend outer tube and dilator. The valve clip is composed of nickel-titanium alloy, cobalt-chromium-nickel-molybdenum-iron alloy, and polyethylene terephthalate material and contains a closure clip, gripping tab, central mechanism, braid, and suture. The adjustable bend guiding catheter is used to provide access to the transcatheter valve clamping system and to reach the designated position. The adjustable curved mid-tube and manipulated inner tube are used to enable the delivery, gripping, and release process of the valve clips within the body.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
GeminiOne Transcatheter Valve Edge-to-Edge Repair System
The transcatheter valve clamp system consists of a valve clamp, an adjustable bend mid-tube, and a manipulated inner tube. The adjustable bend introducer catheter consists of an adjustable bend outer tube and dilator. The valve clip is composed of nickel-titanium alloy, cobalt-chromium-nickel-molybdenum-iron alloy, and polyethylene terephthalate material and contains a closure clip, gripping tab, central mechanism, braid, and suture. The adjustable bend guiding catheter is used to provide access to the transcatheter valve clamping system and to reach the designated position. The adjustable curved mid-tube and manipulated inner tube are used to enable the delivery, gripping, and release process of the valve clips within the body.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
2. An age ≥ 18 years;
3. Diagnostic transthoracic echocardiogram (TTE) obtained within 90 days and transesophageal echocardiogram (TEE) obtained within 180 days to determine the presence of symptomatic moderate-severe or severe degenerative mitral regurgitation (defined as mitral regurgitation grade ≥3+);
4. Patients' New York Heart Association (NYHA) cardiac function classification (see Appendix II) in grades II, III, or non-ambulatory grade IV;
5. Patients' left ventricular ejection fraction LVEF ≥ 20%;
6. Patients considered to be at high surgical risk by the multidisciplinary cardiac team ;
7. Patients are anatomically suitable for mitral valve repair and suitable for the device under this study as assessed by the multidisciplinary cardiac team;
Elements include, however, are not constrained to the following:
1. Mitral valve orifice area ≥ 4.0 cm2;
2. Left ventricular end-systolic dimension (LVESD) ≤ 60 mm;
3. The primary regurgitant bundle is a non-conjunctive regurgitant bundle and if the secondary regurgitant bundle is present, must be clinically insignificant;
4. Transeptal puncture and femoral venipuncture are feasible; The recommended reference criteria for high surgical risk are: an STS score of ≥8 for surgical valve replacement (see Appendix III) or an STS score of ≥6 for surgical valve repair, or the existence of other high-risk factors, such as the presence of other high-risk elements such as the presence of ≥ 2 warning signs of moderate-severe frailty or the presence of feasible surgical operative limitations or the presence of ≥ 2 main organs dysfunctions that cannot be elevated postoperatively or other surgical high-risk factors that are genuinely existing in the judgment of the independent cardiac surgeon in this study.
Exclusion Criteria
2. The presence of other severe heart valve diseases requiring surgical intervention;
3. Leaflet anatomy that may prevent implantation of the valve clip, proper positioning on the leaflet, or prevent adequate reduction of mitral regurgitation by the valve clip. The assessment is based on transesophageal echocardiographic (TEE) mitral valve evaluation within 180 days prior to the subject's registration and includes:
1. inability of the valve clips to hold sufficient active leaflets;
2. lack of primary and secondary tendon support in the clamping area;
3. significant evidence of calcification in the clamping area;
4. significant fissures in the clamping area;
4. Active endocarditis, pericarditis, or rheumatic heart disease; or mitral valve leaflet changes resulting from endocarditis or rheumatic heart disease;
5. Severe right ventricular insufficiency (e.g. with symptoms of bilateral lower limb edema with increased jugular venous pressure and hepatomegaly); or pulmonary hypertension (pulmonary artery systolic pressure PASA \> 70 mmHg as measured by echocardiography);
6. Patients who have had an acute coronary syndrome within 4 weeks, or untreated severe coronary artery stenosis requiring revascularization;
7. Patients with any cardiovascular intervention, cardiac surgery, cardiac resynchronization therapy (CRT, CRT-D), implantation of a buried cardioverter-defibrillator (ICD), etc. within 30 days; or have planned one of these procedures;
8. Patients underwent mitral valve surgery or mitral transcatheter valve surgery before, or have a left atrial appendage occluder device inside;
9. Patients with end-stage heart failure (ACC/AHA stage D), or after cardiac transplantation, or awaiting cardiac transplantation;
10. Patients who are hemodynamically unstable, defined as systolic blood pressure \<90 mmHg without postload-reducing drugs, or in cardiogenic shock; or are requiring intra-aortic balloon counterpulsation, or other hemodynamic support drugs or devices;
11. Patients requiring emergency or urgent surgery for any reason;
12. Patients' femoral vein cannot accommodate a 22F catheter or overlaying ipsilateral deep venous thrombosis, as assessed by the investigator, or are anatomically unsuitable for atrial septum puncture; \[13
13. Patients with active infection requiring concurrent antibiotic treatment; in the case of temporary disease, antibiotics must be discontinued for at least 14 days before enrollment;
14. Patients with a history of any cerebrovascular accident within 30 days; or a severe symptomatic carotid stenosis (carotid ultrasound suggesting \>70% stenosis);
15. Modified Rankin Scale score ≥ 4 (see Annex IV);
16. Patients with a history of acute peptic ulcer or gastrointestinal bleeding within 3 months;
17. Patients with hematological cachexia, including granulocytopenia (WBC \<3 x 109/L), anemia (HB \< 90 g/L), thrombocytopenia (PLT \<50 x 109/L), bleeding disorders, and coagulopathy; or the presence of contraindications to antiplatelet or anticoagulant medication;
18. Patients with a contraindication to transesophageal echocardiography; or a contraindication to general anesthesia;
19. Patients with severe chronic obstructive pulmonary disease (COPD) requiring long-term steroids or continuous home oxygen therapy;
20. Patients with severe hepatic or renal insufficiency (ALT, AST, creatinine \> 2 times the upper limit of normal values);
21. Pregnant or lactating women, or those with a birth plan within 12 months;
22. Patients with known hypersensitivity to device components or contrast media;
23. Patients enrolled in another clinical study and within the follow-up period;
24. Patients with a disease that would make the evaluation of treatment difficult (e.g. cancer, infection, severe metabolic disease, psychiatric disease, etc.); or patients with a life expectancy shorter than 12 months;
25. Patients whose compliance is assessed by the investigator to be poor and are unable to comply with the follow-up schedule and complete the examination; or other situations in which the investigator considers the issue to be unsuitable for participation in the study.
18 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Peijia Medical Technology (Suzhou) Co., Ltd.
INDUSTRY
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Peiga Medical Technology (Suzhou) Co.
Suzhou, Jiangsu, China
Countries
Review the countries where the study has at least one active or historical site.
Central Contacts
Reach out to these primary contacts for questions about participation or study logistics.
Facility Contacts
Find local site contact details for specific facilities participating in the trial.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
22CSP001
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.